Surgical staples: buying guide for staplers and reloads
14 products in the catalogue
Surgical staples are mechanical closure devices that replace manual suturing in certain closures and anastomoses. The products include skin staplers, linear staplers, endoscopic linear staplers and circular staplers, all disposable. Distinguishing the type of instrument is the first step towards avoiding mixed-up references in an order.
The choice does not depend only on the type of stapler: staple height, staple line length, number of staples per reload and staple material determine the correct reference. This guide sets out the criteria to establish before ordering and the details to confirm in the description of each product so as not to mix different platforms.
Other related families
-
Disposable Linear Cutting Stapler Replacement Reload
Allows you to replace the reload without changing instrument, matching the staple height to the one planned by the surgical team.
-
Disposable Surgical Linear Cutting Stapler
Simultaneous stapling and transection with linear staplers, identified by jaw length.
-
Disposable Circular Stapler
Designed for gastrointestinal anastomoses; requires you to establish the nominal diameter and the staple height separately.
-
Disposable Surgical Skin Stapler
Skin closure; chosen by the number of staples in the magazine and by staple size.
-
Disposable Linear Surgical Stapler
Linear stapling without cutting, for closures where the tissue does not need to be divided.
Products in this guide
- Unit 9
- Box OF 20 2
-
Sale!

Disposable Surgical Skin Stapler Type W · 35 Stainless Steel Staples · Width 13.8 mm · Quick and Aesthetic Closure of Incisions (Ref. KHPF-W)
Original price was: 5,00 €.3,90 €Current price is: 3,90 €. In stockAdd to basket -

Endoscopic Linear Surgical Stapler 60 mm · 12 mm Diameter · Three-Staple Technology · Ref. WZULS-A-S
187,50 € In stockAdd to basket -

Endoscopic Linear Surgical Stapler 12 mm · Staple line length 160 mm · Disposable Endocutter · Ref. WZULS-A-L
187,50 € In stockAdd to basket -

Endoscopic Linear Surgical Stapler Endocutter · Line length 260 mm · Diameter 12 mm · Triple Load (Reference WZULS-A-XL)
187,50 € In stockAdd to basket -

Disposable Linear Surgical Stapler 30 mm – Blue Cartridge 3.8 mm, 13 Titanium Staples (Ø 0.28 mm) | Digestive Mechanical Suture
150,00 € In stockAdd to basket -

Disposable Linear Surgical Stapler 30 mm | Green Cartridge 4.5 mm · 13 Titanium Staples (Ø 0.28 mm) · Thick Tissue | WZLS-A-30H
150,00 € In stockAdd to basket -

Disposable Linear Surgical Stapler 45 mm | Blue Titanium Load 3.8 mm · 19 Staples (Ø 0.28 mm) | WZLS-A-45L
150,00 € In stockAdd to basket -

Disposable Linear Surgical Stapler 45 mm – Green Titanium Load 4.5 mm · 19 Staples (Ø 0.28 mm) | WZLS-A-45H
150,00 € In stockAdd to basket
Buying and selection tips
-
Staple height: the first filter
Staple height determines the tissue thickness the reload is designed for. The products include heights such as 3.8 mm and 4.5 mm. First establish the height the surgical team plans to use, and then the rest of the reference.
-
Staple line length
Linear staplers are identified by the length of their staple line or jaws, with models of 30, 45, 60 and 90 mm. Choose the length according to the size of the planned transection, not according to availability, and check in the product description which length is listed.
-
Disposable versus reloadable
Some models are disposable and others allow the reload unit to be changed. Assess the cost per firing by adding the instrument and the reloads you will actually use. If usage volume is low, the disposable version simplifies logistics.
-
Skin stapler: number and size of staples
Skin staplers are identified by the number of staples, for example 35, and by the staple size. Compare the number of staples, width and height according to the product description. A wide staple and a regular one are not interchangeable in the same closure.
-
The reload belongs to its platform
Cartridges and reloads only work in the instrument of the same system. Even if two reloads share a colour or nominal height, they may differ in actual open height. Verify instrument-reload compatibility before grouping references in a tender.
Compatibility
- Circular stapler and gastrointestinal anastomosis
- Before combining instrument and reload, confirm the diameter and staple height, because the nominal diameters of different platforms do not match.
Frequently asked questions
How do I choose the staple height for each type of tissue?
The height must correspond to the tissue thickness anticipated by the surgical team. The products include 3.8 mm and 4.5 mm reloads; confirm the height in millimetres in the description of each reference.
Can I change the reload in the same instrument during a procedure?
Only on reloadable models and with reloads compatible with the instrument's jaw length. On disposable ones the reload cannot be replaced, so it is worth confirming this on each reference.
What is the difference between a wide-staple skin stapler and a regular-staple one?
The dimensions of the staple change: the wide staple closes with greater width and height than the regular one, and both are identified by the number of staples in the magazine. One or the other should be chosen according to the planned closure, and the dimensions confirmed in the product description.
Can I use a reload from another platform in my stapler?
No. Cartridges only work in the applier of the same system, and two reloads of the same colour may have different open heights. The check must be made against the specific reference of the instrument.
What details should I confirm before ordering a circular stapler?
Nominal diameter, staple height and the version for thick or thin tissue. The products include diameters of 24 and 26 mm, which are not equivalent, so it is worth confirming each size before ordering.
Common questions
Believing that the colour of the reload identifies the staple height
Colour is a convention of each platform and not a metric value. Two reloads of the same colour may differ in open height, so the comparison should be made using the height in millimetres and the platform they attach to.
Confusing the jaw length with the cutting line
The jaw length does not necessarily match the length of tissue divided. Check in the description which length is listed before comparing references.
Assuming that the wide skin staple and the regular one are the same staple
The dimensions of the staple differ between the two, and the number of staples in the magazine is a separate detail from the staple size.
More products in this guide
-

Disposable Linear Surgical Stapler 60 mm | Blue Titanium Load 3.8 mm · 25 Staples | WZLS-A-60L
150,00 € In stockAdd to basket -

Disposable Linear Surgical Stapler 60 mm – Green Titanium Load 4.5 mm · 25 Staples (Ø 0.28 mm) | WZLS-A-60H
150,00 € In stockAdd to basket -

Disposable Linear Surgical Stapler 90 mm – Blue (WZLS-A-90L) · 39 Titanium Staples · Diameter 0.28 mm · Height 3.8 mm
150,00 € In stockAdd to basket -

Disposable 90 mm Green Linear Surgical Stapler (WZLS-A-90H) – 39 Titanium Staples · Diameter 0.28 mm · Height 4.5 mm
150,00 € In stockAdd to basket -

Disposable circular stapler 24 mm KHGXA-24 (WZCS-A-24) | Mechanical suture for digestive anastomosis | Length 450 mm, titanium staple 5 mm and Ø 0.28 mm
150,00 € In stockAdd to basket




