Description
1. Commercial Introduction
The disposable linear surgical stapler WZLS-A-60H is the mechanical suture solution your healthcare facility needs for open surgery procedures on the digestive tract, resection of viscera and closure of incisions. Its single-use design eliminates reprocessing costs and guarantees a new, sterile instrument with full stapling capacity in each intervention, providing the safety and traceability required by the surgical block.
Manufactured with high-strength titanium staples, it offers a firm and homogeneous seal that reduces postoperative bleeding and shortens suture times compared with manual technique. Its value for money and ergonomics make it a common choice in general and digestive surgery operating theatres, with a cost per procedure significantly lower than premium market references.
2. Technical explanation of the equipment
This device applies two interlocking and staggered lines of titanium staples to the tissue, fixing both edges with a homogeneous distribution of tension and an effective haemostatic seal. The staggered (non-opposed) configuration reduces point pressure on the wall and minimises the risk of postoperative bleeding and anastomotic leakage.
The stapler combines manual and automatic actuation with audible signals that confirm correct closure of the anvil and release of the load: the surgeon perceives when stapling has been completed, avoiding incomplete firings. The narrow-design anvil reduces the footprint on healthy peripheral tissue, favouring preservation of local irrigation and cleaner healing.
The green 4.5 mm load is especially indicated for thick or oedematous tissue: thickened intestinal wall, pulmonary parenchyma, closure of stumps in gastric or intestinal resections, side-to-side anastomoses and visceral transections. Being single-use, the risk of cross-infection is eliminated and the sharpness of the mechanism is ensured in each application.
3. Technical Specifications
| Specification | Value |
| Reference | WZLS-A-60H |
| Device type | Disposable linear stapler (open surgery, non-cutting) |
| Staple line length | 60 mm |
| Staple wire diameter | 0.28 mm |
| Staple height | 4.5 mm |
| Load identification colour | Green (thick tissue) |
| Number of staples per unit | 25 |
| Staple rows | 2 staggered (interlocked) rows of titanium |
| Staple material | Titanium (imported wire) |
| Anvil | Narrow design, protects peripheral tissue |
| Actuation | Manual and automatic with audible signals |
| Use | Single-use (disposable), single fire |
| Sterilisation | Ethylene oxide (EO), individually packaged |
| Composition | Latex-free and DEHP-free |
| Expiry | 3 years from the date of manufacture |
| Presentation | Sterile unit in individual blister |
| Application | Closure and suture of incisions, resection of viscera and reconstructive surgery of the digestive tract |
WZLS-A family table (factory references): the series combines four staple line lengths (30, 45, 60 and 90 mm) with two staple heights (3.8 mm blue for standard tissue and 4.5 mm green for thick tissue), allowing the instrument to be adjusted to each surgical demand.
| Model | Length (mm) | Staple height (mm) | Colour | No. of staples |
| WZLS-A-30L | 30 | 3.8 | Blue | 13 |
| WZLS-A-30H | 30 | 4.5 | Green | 13 |
| WZLS-A-45L | 45 | 3.8 | Blue | 19 |
| WZLS-A-45H | 45 | 4.5 | Green | 19 |
| WZLS-A-60L | 60 | 3.8 | Blue | 25 |
| WZLS-A-60H (this model) | 60 | 4.5 | Green | 25 |
| WZLS-A-90L | 90 | 3.8 | Blue | 39 |
| WZLS-A-90H | 90 | 4.5 | Green | 39 |
Note: the closed staple height does not appear in the distributor’s data sheet; equivalent models in the range with thick tissue load record closing heights of approximately 2.0 mm, a figure offered as a market reference pending confirmation with the manufacturer.
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing the WZLS-A series with the references of major Western houses, so the technical department must be consulted before use in tenders. The following references are offered as a functional category comparison verified against each manufacturer’s sources, never as direct 1:1 interchangeable items (dimensions, number of staples, height, handle system and regulatory classification vary, and their specifications must be validated before any substitution):
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Medtronic (Covidien) | TA™ with DST Series™ technology | TA6048S (instrument) / TA6048L (reload) | Comparable by category (not interchangeable 1:1) | 60 mm, green, titanium, 2 rows; open height 4.8 mm (closed 2.0 mm) versus 4.5 mm; 21 staples versus 25; reloadable instrument up to 8 firings versus disposable |
| Ethicon (Johnson & Johnson MedTech) | PROXIMATE™ Reloadable Linear Stapler | TX60G | Comparable by category (not interchangeable 1:1) | 60 mm with green reload for thick tissue; 21 titanium staples with B-Form technology; reloadable handle and higher price segment |
| B. Braun (Aesculap) | LS linear stapler | LS Series 60 mm · Height 4.8 · Green | Comparable by category (not interchangeable 1:1) | 60 mm, green, height 4.8 mm versus 4.5 mm; proprietary structure and own number of staples; verify system compatibility |
| Purple Surgical | Ultimate Reloadable Linear Stapler | Ultimate Series 60 mm · 4.8 mm green | Comparable by category (not interchangeable 1:1) | Reloadable up to 8 fires; height 4.8 mm versus 4.5 mm; different number of staples |
| Volkmann Med | Reloadable Linear Stapler | Series 60 mm, thick tissue reload 4.5 mm | Comparable by category (not interchangeable 1:1) | Reloadable (not disposable); the thick tissue load height matches the WZLS-A series |
Note on codes: TA6048S / TA6048L appear consistently in official Medtronic sources and authorised distributors, and TX60G appears in the official Ethicon catalogue; they are cited as verified control references. The internal code WZLS-A-60H is Cahnos’s own reference and has not been found in independent public sources, so it should be treated as a factory/distributor code and confirmed with the manufacturer before use in technical specifications.
5. Selection tips and variants of interest
- Choice of staple height: the green 4.5 mm load (this model) is designed for thick, oedematous or parenchymatous tissue (thickened gastric or intestinal wall, pulmonary parenchyma). For standard or thin-walled tissue select the blue 3.8 mm load (WZLS-A-60L).
- Choice of line length: the 60 mm model is the most common balance in digestive and general surgery; for short closures or pedicles use the 30 or 45 mm versions, and for wide parenchymal or gastric transections use the 90 mm version (WZLS-A-90H).
- Prior checks: confirm the wall thickness with the compression instrument before firing, check the integrity of the sterile packaging and the expiry date, and do not reuse or re-sterilise the device.
- Range variants: if your department requires stapling with simultaneous cutting, consult the family of reloadable linear cutting staplers WZCTS-A (60/80/100 mm) and their spare parts; for laparoscopic approaches, the range of endoscopic linear staplers and articulated spare loads.
- For tenders: as there is no official manufacturer cross-reference table, validate each equivalence with the technical department and provide the technical data sheets of the comparable products before submitting a tender.










Reviews