We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Linear Surgical Stapler 90 mm – Blue (WZLS-A-90L) · 39 Titanium Staples · Diameter 0.28 mm · Height 3.8 mm

150,00 €

Disposable 90 mm linear surgical stapler with two interlocked rows of titanium staples of 0.28 mm diameter and 3.8 mm height (blue colour identification). Each unit applies 39 staples to suture and close incisions in reconstructive surgery of the digestive tract and in viscera resection, with a narrow anvil design that minimises damage to peripheral tissue and prevents postoperative bleeding. Manual and automatic operation with audible signals for precise, homogeneous and safe stapling. Reference WZLS-A-90L, single-use product, sterilised and ready for the operating theatre.

International shipping. Import duties and taxes are payable by the recipient.

Reference
WZLS-A-90L
Tags

Description

1. Disposable linear stapler for digestive tract surgery

The disposable linear surgical stapler WZLS-A-90L is the mechanical suture solution your healthcare facility needs for open surgery procedures on the digestive tract, viscera resection and closure of incisions. Its disposable design eliminates reprocessing costs and guarantees a new, sharp and sterile instrument in each intervention, with the safety and traceability required in the operating theatre. Manufactured with high-resistance titanium staples, it offers a firm and homogeneous seal that reduces postoperative bleeding and shortens suture times compared to manual technique.

2. Technical explanation of the equipment

This device applies two interlocked (staggered) rows of titanium staples that stitch the tissue simultaneously, creating a continuous, uniform suture line without tension differences. The anvil features a narrow design that reduces the risk of damaging peripheral tissue and facilitates access to difficult-to-expose areas. The stapler combines manual and automatic operation with audible signals, allowing the surgeon to control each firing phase and confirm complete closure of the handle before releasing the staples. The 90 mm staple line configuration with blue staples of 3.8 mm height is indicated for normal or thin-wall tissue: closure of incisions, visceral transections, stump closure in gastric or intestinal resections and side-to-side anastomoses. Being single-use, the risk of cross-infection is eliminated and the sharpness of the mechanism is ensured in each application.

3. Technical Specifications

Product reference WZLS-A-90L
Device type Disposable linear stapler (open surgery, non-cutting)
Staple line length 90 mm
Staple wire diameter 0.28 mm
Staple height 3.8 mm
Staple identification colour Blue (normal tissue / thin wall)
Number of staples per unit 39
Staple rows 2 staggered (interlocked) rows of titanium
Staple material Titanium
Anvil Narrow design, protects peripheral tissue
Actuation Manual and automatic with audible signals
Use Single-use (disposable)
Sterilisation Ethylene oxide (EO), individually packaged
Application Closure and suture of incisions, resection of viscera and reconstructive surgery of the digestive tract

WZLS-A family table (factory references):

Model Length (mm) Staple height (mm) Colour Number of staples
WZLS-A-30L 30 3.8 Blue 13
WZLS-A-30H 30 4.5 Green 13
WZLS-A-45L 45 3.8 Blue 19
WZLS-A-45H 45 4.5 Green 19
WZLS-A-60L 60 3.8 Blue 25
WZLS-A-60H 60 4.5 Green 25
WZLS-A-90L 90 3.8 Blue 39
WZLS-A-90H 90 4.5 Green 39

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer that cross-references the WZLS-A series with the references of major Western brands; consult the technical department before use in tenders. The following references are offered as a functional category comparison verified against each manufacturer’s sources, never as direct 1:1 interchangeables, and their specifications must be validated before any substitution.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Medtronic (Covidien) TA™ with DST Series™ technology TA9035S (instrument) / TA9035L (reload) Comparable by category 90 mm, blue, titanium, 2 rows; open height 3.5 mm (closed 1.5 mm) versus 3.8 mm; 33 staples versus 39; reloadable instrument up to 8 firings
Ethicon (Johnson & Johnson MedTech) PROXIMATE™ TX TX 90 series (blue reload, normal tissue) Not verified 1:1 – comparable by category 90 mm with blue staples of 3.5 mm for standard tissue; confirm exact reference and number of staples with the manufacturer
B. Braun (Aesculap) LS – Linear Stapler LS9035 Comparable by category 90 mm, blue, double row, open surgery; height 3.5 mm versus 3.8 mm; proprietary structure, verify system compatibility
Purple Surgical Ultimate Reloadable Linear Stapler PS9LSI90B (instrument) / PS9LSR90B (reload) Not verified 1:1 – comparable by category 90 mm, blue 3.5 mm for standard tissue; reloadable up to 7 reloads (8 firings); confirm codes with the manufacturer (the green version PS9LSR90G does appear in public sources)
Lantex / Infiniti Medical Linear Stapler LS90B (instrument) / LSR90B (reload) Comparable by category 90 mm, blue, two rows of titanium staples; proprietary structure and own number of staples; verify system compatibility

Note on codes: TA9035S and TA9035L appear consistently in Medtronic sources and authorised distributors, and LS9035 appears in the official catalogue of B. Braun (Aesculap); they are cited as control references. The internal code WZLS-A-90L is Cahnos’ own reference (manufacturer WZ); it has not been found in independent public sources, so it should be treated as a distributor/factory code and confirmed with the manufacturer before use in tender documents.

5. Selection tips and variants of interest

  • Line length: choose 30 mm (WZLS-A-30), 45 mm (WZLS-A-45), 60 mm (WZLS-A-60) or 90 mm (WZLS-A-90) according to the extent of the tissue to be sutured and the depth of the surgical field.
  • Staple height / colour: the blue version (3.8 mm, this model) is suitable for normal or thin-wall tissue; the green version (4.5 mm) is intended for thick, oedematous tissue or with greater compression requirements, such as pulmonary parenchyma or thickened intestine.
  • Single-use: verify the integrity of the sterile packaging before opening and do not reuse the device; dispose of it according to the centre’s protocol after each intervention.
  • Range variants: if your department requires stapling with simultaneous cutting, consult the family of reloadable linear cutting staplers WZCTS-A (60/80/100 mm) and their spare parts; for laparoscopic approaches, the range of endoscopic linear staplers and articulated spare loads.
  • For tenders: since there is no official cross-reference table from the manufacturer, validate each equivalence with the technical department and provide the technical data sheets of the comparables before submitting a bid.

Additional information

Reference

WZLS-A-90L

Device type

Disposable linear stapler (open surgery, non-cutting)

Staple line length

90 mm

Staple wire diameter

0.28 mm

Staple height

3.8 mm (open)

Staple colour

Blue (normal tissue / thin wall)

Staple count

39

Staple rows

2 staggered rows (interlocked)

Staple material

Titanium

Anvil

Narrow design, protects peripheral tissue

Actuation

Manual and automatic with audible signals

Use

Single-use (disposable)

Sterilisation

Ethylene oxide (EO), individually packaged

Application

Closure and suture of incisions, resection of viscera and reconstructive surgery of the digestive tract

Reviews

There are no reviews yet.

Be the first to review “Disposable Linear Surgical Stapler 90 mm – Blue (WZLS-A-90L) · 39 Titanium Staples · Diameter 0.28 mm · Height 3.8 mm”

Your email address will not be published. Required fields are marked *