Description
1. Introduction: laparoscopic precision for digestive surgery
The Endoscopic Linear Surgical Stapler (reference WZULS-A-S) is a single-use laparoscopic endocutter designed to offer precision, haemostasis and safety in minimally invasive procedures of the gastrointestinal tract. With a stapling line length of 60 mm and a shaft diameter of 12 mm, compatible with standard laparoscopic trocars, it allows access to deep anatomical areas without enlarging the entry ports. It is the ideal solution for operating theatres of digestive surgery, general surgery and thoracic surgery seeking a complete mechanical suture system with interchangeable loads and controlled cost, available at Cahnos at the best price on the market.
2. How it works: triple staple technology and B-shaped closure
The endoscopic linear stapler simultaneously places two triple staggered rows of titanium staples (six rows per load) and divides the tissue between them using an integrated blade. The so-called three-staple technology provides three staggered staple heights from the inner row to the outer row: the tissue, when compressed by the anvil, receives progressive pressure that improves perfusion, reduces tissue tension and promotes correct B-shaped staple formation, a classic indicator of reliable mechanical suture with good sealing and haemostatic effect. The special rotation system allows the distal end to be rotated stably, smoothly and easily, even with one hand; the anvil design facilitates blunt dissection and visualisation of vessels during resection; and the disposable load unit ensures the blade is sharpened on each firing, minimising the risk of transfer and cross-infection of tumour cells.
3. Technical Specifications
| Parameter | Specification |
| Product reference | WZULS-A-S |
| Device type | Single-use endoscopic linear stapler (laparoscopic endocutter) |
| Staple line length | 60 mm (base model); accepts loads of 30 mm and 45 mm |
| Shaft diameter | 12 mm (standard laparoscopic trocar) |
| Total instrument length | 277 ± 5 mm (factory specification) |
| Staple system | Three-staple technology (double triple staggered row, 6 rows) |
| Staple material | Titanium |
| Staple closure shape | B-shaped closure |
| Rotation | Special rotation system for stable and smooth rotation |
| Applications | Resection, anastomosis and transection of the gastrointestinal tract |
| Use | Single-use (disposable), sterile |
| Presentation | Individual unit |
WZULS-A handle family (factory references)
| Model | Total length L (mm) | Line length according to data sheet |
| WZULS-A-S | 277 ± 5 | 60 mm |
| WZULS-A-L | 377 ± 5 | 160 mm |
| WZULS-A-XL | 477 ± 5 | 260 mm |
Compatible replacement cartridges (same WZULS system, 12 mm diameter)
| Series | Configuration | Lengths | Heights / colours | Reference example |
| WZULS-P1 | Straight single-height cartridge | 30 / 45 / 60 mm | White 2.5 mm · Blue 3.5 mm · Green 4.8 mm | WZULS-P1-45-3.5 |
| WZULS-P2 | Articulating cartridge | 30 / 45 / 60 mm | White 2.5 mm · Blue 3.5 mm · Green 4.8 mm | WZULS-P2-45-2.5 |
| WZULS-P3 | Triple staggered load | 30 / 45 / 60 mm | Brown 2.0-2.5-3.0 · Purple 3.0-3.5-4.0 · Black 4.0-4.5-5.0 | WZULS-P3-45B-2.0,2.5,3.0 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing the WZULS-A-S handle with the references of the major Western houses: each platform uses its own proprietary fixation system and loads, so they are not interchangeable 1:1. The following references are offered as a functional category comparison verified against each manufacturer’s sources, never as direct substitutes:
| Manufacturer / Brand | Model / Reference | Equivalence level | Technical differences / Remarks |
| Medtronic / Covidien | Endo GIA™ Ultra Universal Stapler (EGIAUSTND): standard 12 mm handle, 45° articulation, single-use | Comparable by category | Same clinical function and 12 mm calibre, but proprietary Endo GIA cartridge system: not 1:1 interchangeable. |
| Medtronic / Covidien | Tri-Staple cartridges (e.g. EGIA45AVM / EGIA60AVM, vascular grey cartridges 2.0 / 2.5 / 3.0 mm) | Comparable by category | Same philosophy of triple staggered height with titanium staples; proprietary to the Endo GIA handle, not interchangeable with WZULS. |
| Medtronic (Signia) | SIG60AVM / SIG45AXT (Tri-Staple 2.0 cartridges) | Comparable by category | Cartridges for the Signia powered handle; proprietary system, not interchangeable. |
| Ethicon (Johnson & Johnson MedTech) | ECHELON FLEX™ ENDOPATH™ Articulating Endoscopic Linear Cutter (EC60A / EC45A) and GST loads (GST60W, GST45W, GST45G, GST60B) | Comparable by category | Single-use 12 mm endocutter with single-height GST loads (B-Form), not triple staggered; proprietary system, not interchangeable 1:1. |
Closing statement: there is no manufacturer-validated equivalence table for this endoscopic handle; consult our technical department before using any substitution in tender documents or surgical protocols. The compatible original loads are exclusively those of the WZULS-P1, WZULS-P2 and WZULS-P3 series.
5. Selection tips and variants of interest
Handle selection by reach: the WZULS-A series offers three lengths (S: 277 mm / L: 377 mm / XL: 477 mm total length). The WZULS-A-S model (this reference) has the shortest reach, indicated for medium-depth access in digestive and general surgery; for deep approaches consider WZULS-A-L or WZULS-A-XL.
Load selection by tissue: fine or vascular tissue with lower-height loads (white 2.5 mm in P1/P2 or brown 2.0-2.5-3.0 mm in P3); medium tissue with blue 3.5 mm or purple 3.0-3.5-4.0 mm; and thick or extra-thick tissue with green 4.8 mm or black 4.0-4.5-5.0 mm. The staple line length (30, 45 or 60 mm) is selected according to the extent of the planned suture or resection.
Variants of interest at Cahnos: as consumables, the WZULS-P3 load family (triple-load) is most suitable when tissues have heterogeneous thicknesses, while WZULS-P1 (straight) and WZULS-P2 (articulating) cover single-height lines. Before firing, verify the load engagement with the positioning click and the closure signal; do not reuse or re-sterilise the unit. For tender use or compatibility questions, consult our technical department.