Description
1. Introduction: laparoscopic precision for digestive surgery
The Endoscopic Linear Surgical Stapler (Ref. WZULS-A-L) is a single-use laparoscopic endocutter designed to offer precision, haemostasis and safety in minimally invasive procedures of the gastrointestinal tract. With a staple line length of 160 mm and a shaft diameter of 12 mm, compatible with standard laparoscopic trocars, it allows access to deep anatomical areas without enlarging the entry ports. It is the ideal solution for operating theatres of digestive surgery, general surgery and thoracic surgery that seek a complete mechanical suture system with interchangeable cartridges and controlled cost, available at Cahnos with competitive B2B conditions.
2. How it works: triple staple technology and B-shaped closure
The endoscopic linear stapler simultaneously places two triple staggered rows of titanium staples (six rows per cartridge) and divides the tissue between them with an integrated blade. The so-called triple staple technology provides three staggered staple heights from the inner row to the outer row: the tissue, when compressed by the anvil, receives progressive pressure that improves perfusion, reduces tissue tension and promotes the correct formation of the staple in a «B» shape, a classic indicator of a reliable mechanical suture with good sealing and haemostatic effect.
The special rotation system allows the distal end to be rotated in a stable, smooth and easy manner, even with one hand; the anvil design facilitates blunt dissection and visualisation of vessels during resection; and the disposable loading unit guarantees the sharpness of the knife on each firing, minimising the risk of transfer and cross-infection of tumour cells.
3. Technical Specifications
| Parameter | Specification |
| Product reference | WZULS-A-L |
| Device type | Single-use endoscopic linear stapler (laparoscopic endocutter) |
| Staple line length | 160 mm (manufacturer’s data sheet) |
| Shaft diameter | 12 mm (standard laparoscopic trocar) |
| Total instrument length | 377 ± 5 mm (manufacturer’s data sheet) |
| Staple system | Three-staple technology (double triple staggered row, 6 rows) |
| Staple material | Titanium |
| Staple closure shape | B-shaped closure |
| Rotation | Special rotation system for stable and smooth rotation |
| Applications | Resection, anastomosis and transection of the gastrointestinal tract |
| Use | Single-use (disposable), sterile |
| Presentation | Individual unit |
WZULS-A handle family (manufacturer’s data sheet)
| Model | Total length L (mm) | Line length according to data sheet |
| WZULS-A-S | 277 ± 5 | 60 mm |
| WZULS-A-L | 377 ± 5 | 160 mm (this reference) |
| WZULS-A-XL | 477 ± 5 | 260 mm |
Compatible replacement cartridges (same WZULS system, 12 mm diameter)
| Series | Configuration | Lengths | Heights / colours |
| WZULS-P1 | Straight single-height cartridge | 30 / 45 / 60 mm | White 2.5 mm · Blue 3.5 mm · Green 4.8 mm |
| WZULS-P2 | Articulating cartridge | 30 / 45 / 60 mm | White 2.5 mm · Blue 3.5 mm · Green 4.8 mm |
| WZULS-P3 | Triple staggered load | 30 / 45 / 60 mm | Brown 2.0-2.5-3.0 · Purple 3.0-3.5-4.0 · Black 4.0-4.5-5.0 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing the WZULS-A-L handle with the references of the major Western houses: each platform uses its own proprietary fixation system and cartridges, so they are not interchangeable 1:1. The following references are offered as a functional category comparison verified against each manufacturer’s sources, never as direct substitutes:
| Manufacturer / Brand | Model / Reference | Equivalence level | Technical differences / Remarks |
| Medtronic / Covidien | Endo GIA™ Ultra Universal Stapler (EGIAUSTND): standard 12 mm handle, 45° articulation, single-use | Comparable by category (not interchangeable 1:1) | Same clinical function and 12 mm calibre, but proprietary Endo GIA cartridge system. |
| Medtronic / Covidien | Tri-Staple cartridges (e.g. EGIA45AVM / EGIA60AVM, vascular grey cartridges 2.0 / 2.5 / 3.0 mm) | Comparable by category (not interchangeable 1:1) | Same triple staggered height philosophy with titanium staples; proprietary to the Endo GIA handle. |
| Medtronic (Signia) | SIG60AVM / SIG45AXT (Tri-Staple 2.0 cartridges) | Comparable by category (not interchangeable 1:1) | Cartridges for the Signia motorised handle; proprietary system. |
| Ethicon (Johnson & Johnson MedTech) | ECHELON FLEX™ ENDOPATH™ Articulating Endoscopic Linear Cutter (EC60A / EC45A) and GST cartridges (GST60W, GST45W, GST45G, GST60B) | Comparable by category (not interchangeable 1:1) | Single-use 12 mm endocutter with single-height GST cartridges (B-Form), not triple staggered. |
There is no manufacturer-validated equivalence table for this endoscopic handle; consult our technical department before using any substitution in tender documents or surgical protocols. The compatible original cartridges are exclusively those from the WZULS-P1, WZULS-P2 and WZULS-P3 series.
5. Selection tips and variants of interest
Choice of handle according to reach: the WZULS-A series offers three lengths (S: 277 mm / L: 377 mm / XL: 477 mm total length). The WZULS-A-L model (this reference) is the intermediate option in the range, indicated for the balance between reach and manoeuvrability in digestive and general surgery; for deeper access consider WZULS-A-XL.
Choice of cartridge according to tissue: fine or vascular tissue with lower-height cartridges (white 2.5 mm in P1/P2 or brown 2.0-2.5-3.0 mm in P3); medium tissue with blue 3.5 mm or purple 3.0-3.5-4.0 mm; and thick or extra-thick tissue with green 4.8 mm or black 4.0-4.5-5.0 mm. The staple line length (30, 45 or 60 mm) is selected according to the extent of the suture or planned resection.
Variants of interest at Cahnos: as consumables, the WZULS-P3 cartridge family (triple cartridge) is the most suitable when tissues present heterogeneous thicknesses, while WZULS-P1 (straight) and WZULS-P2 (articulating) cover single-height lines. Before firing, verify the cartridge fit with the positioning click and the closure signal; do not reuse or re-sterilise the unit. For use in tenders or compatibility queries, consult our technical department.











Reviews