Load Control Systems
In the Load Control Systems category at Cahnos, we bring together the challenge test (PCD) devices and kits designed to routinely validate the performance of sterilisation equipment in hospitals, sterilisation centres (CEYE), dental clinics, laboratories and veterinary practices. These systems simulate the most difficult load to penetrate inside the autoclave —hollow instruments, long lumens, porous bodies and complex devices— and, combined with Type 2 chemical indicators, allow the correct penetration of the sterilising agent, the removal of residual air and the suitability of Bowie & Dick cycles to be documented on an objective basis. In this way, the sterilisation professional, the quality manager or the biomedical technical service obtains traceable evidence before releasing a load, reducing reprocessing, complaints and failed audits, and ensuring compliance with standards such as UNE-EN ISO 17665, UNE-EN ISO 11140 or each country’s good practice guidelines.Main applications and variety:Helix Test PCD Kits for steam (Bowie & Dick): air removal and steam penetration test devices for vacuum-assisted autoclaves, with a highly durable metal or plastic capsule and printed self-adhesive strips; available in tube lengths and geometries adapted to 3.5 min cycles at 134 °C and to large-capacity equipment.Helix Test PCD Kits for hydrogen peroxide: specific systems for VPHP/plasma processes with a Type 2 chemical indicator, resistant plastic capsule and 1.2 m tube with silicone connector, designed for the safe release of hollow loads in low-temperature cycles.Helix Test PCD Kits for formaldehyde (FO): PCD devices validated for VFBT processes with indicator strips formulated for this agent, which allow the penetration of formaldehyde into narrow lumens and heat-sensitive materials to be documented.Compatible chemical indicators and consumables: self-adhesive printing strips, indicator ink refills and connection accessories to maintain the daily, weekly and equipment qualification plan within the sterilisation assurance programme.
Products
Showing all 7 results
-

Plus Steam Adhesive Tape 25 mm x 50 m with Chemical Indicator – Package Sealing for Steam Sterilisation (121/134 ºC) | SKU 381-S
260,00 € In stockAdd to basket -

Bowie & Dick UPSTAR Test Ready to Use – Steam Penetration Test Pack for Autoclaves (134 °C / 3 min 30 s) – Single-Use Chemical Indicator (Ref. 35853)
5,61 € On orderAdd to basket -

Helix Test PCD Kit for Steam KH2X15-35 CHEMDYE® – Bowie & Dick Helix-Type Test with Type 2 Chemical Indicator and 250 Simulation Strips for Steam Sterilisation
291,66 € In stockAdd to basket -

Helix Test PCD Kit KH2X15F1P for CHEMDYE® Formaldehyde – Low-Temperature VFBT Sterilisation Control with Type 2 Chemical Indicator Strips (250 units + Helix-PCD)
291,66 € In stockAdd to basket -

Kit Helix Test PCD for Hydrogen Peroxide CHEMDYE® KH2X12-P1 – Control of sterilisation processes by vH2O2 and gas plasma with Type 2 chemical indicator and self-adhesive strips
375,00 € In stockAdd to basket -

Multivariable Class 4 Steam Indicator Strips (Type 4) – Dual Double Strip, 134 °C / 3.5 min, ISO 11140-1 – Box of 250 units | Ref. 35954
16,63 € In stockAdd to basket -

Type 6 Emulating Strips for Steam – Chemical Cycle Indicator (ISO 11140-1) for Autoclave 121/134 ºC – Box of 250 Strips | Ref. 35955
25,65 € On orderAdd to basket
The choice of the appropriate load control system depends, firstly, on the sterilising agent used (saturated steam, vaporised hydrogen peroxide or formaldehyde), since each technology requires a PCD and a chemical indicator specifically formulated for it; on the geometry and size of the devices being reprocessed, because longer or narrower lumens require longer tubes and capsules with greater restriction; and on the type of cycle and the vacuum level of the autoclave, which determines the daily test (Bowie & Dick), the hollow load release test and the qualification controls. It is also worth considering the durability of the PCD body (metal versus plastic capsule), the traceability offered by the indicator printing support, the ease of filing the test strip and consistency with the unit's internal protocols. At Cahnos we help sterilisation centres and technical services to define the optimal Helix Test PCD kit for each autoclave and to standardise the control batches that must be replenished periodically.
Do you need advice on selecting the most suitable load control system for your equipment, or are you preparing a volume order for your sterilisation centre? Contact our technical-healthcare team and we will guide you in choosing the recommended PCD, chemical indicator and frequency of use for your operation, with personalised attention and special conditions for bulk purchases.