1. Product Presentation
The Helix Test PCD Kit KH2X12-P1 from the CHEMDYE® range (Pergut Medical) is the process control solution that every sterilisation centre needs to validate low-temperature cycles using vaporised hydrogen peroxide (vH2O2) and gas plasma. It is specifically designed for the safe release of hollow loads, the most demanding and critical load profile of low-temperature sterilisers.
Each kit includes the reusable Helix-PCD process challenge device, together with self-adhesive test strips with Type 2 chemical indicator, presented in sheets of 10 units. A complete system ready for daily use in hospitals, clinics, pharmaceutical industry and medical device processing companies.
2. Technical explanation of the procedure
The Helix-PCD is a process challenge device (PCD) that reproduces the worst possible scenario of sterilising agent penetration in lumen instruments: the hydrogen peroxide vapour must travel through a plastic tube of 1.2 m length with only 2 mm internal diameter before reaching the chemical indicator. The highly durable plastic capsule houses the indicator strip and the special silicone connector, covered by an external protective connector, ensures an airtight seal and a secure connection to the equipment.
The PCD-A-P1 strip is a Type 2 chemical indicator conforming to ISO 11140-1, printed with indicator ink that changes colour only when the hydrogen peroxide cycle has been carried out under correct conditions. If the colour change is complete and uniform, the result is conforming and the equipment is working correctly; if the change is insufficient or irregular, it indicates poor penetration of the sterilising agent and therefore a malfunction of the steriliser.
3. Technical Specifications
Technical data sheet for the KH2X12-P1 kit
| Characteristic | Specification |
|---|---|
| Product type | Helix-PCD kit + test strips with chemical indicator for hydrogen peroxide |
| Reference | KH2X12-P1 |
| Processing | Sterilisation by hydrogen peroxide vapour (vH2O2) and gas plasma |
| Application | Sterilisation process control; safe release of hollow loads |
| Capsule | Highly durable plastic housing the chemical indicator of the Helix-PCD system |
| Connection tubing | High-strength plastic, 1.2 m length and 2 mm internal diameter |
| Connector | Special silicone connector covered by an external protective connector |
| Chemical indicator | PCD-A-P1, Type 2 (ISO 11140-1) |
| Indicator strip | Self-adhesive, 76 x 6 mm, printed with indicator ink; 10 strips per sheet |
| Presentation | 1 Helix-PCD device + 100 strips per box |
| Helix-PCD service life | Reusable up to 250 cycles |
| Storage | T 10–30 ºC, RH 30–80 %, protected from light; do not store near sterilising agents |
| Regulatory standard | EN ISO 11140-1 and EN 867-5 |
| Manufacturer | Pergut Medical, S.L.U. (Spain) |
4. Equivalences and Cross-References
This kit belongs to the Helix process challenge device family from Pergut Medical (CHEMDYE® range). The following company references are available in the same Helix-PCD system:
| Reference | Description | Presentation |
|---|---|---|
| KH2X15-35 | Helix Test PCD kit + simulation strips for steam | 250 strips/box |
| KH2X15F1P | Helix Test PCD kit + strips for vaporised formaldehyde (VFBT / LTSF) | 250 strips/box |
| KH2X15-35B | B&D type Helix test for steam (metallic device, ISO 11140-4) | On request |
| BD125X/20 | Bowie-Dick type Helix test for steam (1.5 m x 2 mm) | 20 uds/caja |
| 24102 | Bowie-Dick test package for daily control (120 x 120 x 17 mm) | 20 uds/caja |
As complementary consumables for hydrogen peroxide processes, Pergut Medical offers the CD40 multiparametric chemical indicator (Type 4, 105 x 18 mm), the CT40 indicator adhesive tape (20 mm x 50 m, with colour change from purple to green) and specific biological controls for gas plasma, available in the Cahnos catalogue. On the international market, functionally equivalent kits are marketed under the nomenclature KH2X12-P1 with identical conformity to ISO 11140-1 Type 2 and EN 867-5.
5. Selection tips and variants of interest
- Hollow load: if your low-temperature steriliser processes endoscopes, laparoscopes, cannulas or other long-lumen instruments, the Helix-type test is the appropriate one. The KH2X12-P1 kit is the specific variant for vH2O2 and gas plasma; it must not be used in steam, ethylene oxide, dry heat or formaldehyde cycles.
- Other processes: to validate steam cycles use reference KH2X15-35 and for vaporised formaldehyde use KH2X15F1P. The kit also allows verifying the penetration of the agent at the worst point of the load before batch release.
- Frequency of use: carry out the test periodically following the equipment manufacturer’s protocol and standard ISO 11140-1. The Helix-PCD supports up to 250 cycles; replace the PCD-A-P1 strips when they run out and always verify that the colour change is complete.
- Storage and handling: keep the product in its original packaging, protected from light, in a cool, dry place, away from sterilising agents; check the integrity of the packaging before each cycle.
- Professional B2B purchase: for sterilisation centres, hospitals, pharmaceutical industry and processing companies, consult our technical-commercial team for volume conditions and continuous supply.