Description
1. Commercial Introduction
The AINSEWHITE intrauterine insemination cannula (ref. 770219) is a disposable, sterile device designed to facilitate the transfer of washed and capacitated sperm into the uterine cavity in artificial insemination (AI) procedures. Its handleless configuration and soft, transparent body offer excellent manoeuvrability during the procedure, while also allowing visual verification of the correct deposition of the sample. It is the reference tool for gynaecology units, assisted reproduction clinics, fertility laboratories and AI centres that require reliable, reproducible and traceable performance, with the assurance of embryotoxicity (MEA) and bacterial endotoxin (LAL) tests.
2. Technical explanation of the procedure
Intrauterine artificial insemination consists of depositing a sample of washed and capacitated sperm directly into the uterine cavity at the optimal time of the ovulatory cycle, increasing the concentration of spermatozoa in the appropriate place. The AINSEWHITE cannula features a rounded tip with two lateral orifices that promote a balanced distribution of seminal fluid, a centimetre measurement scale engraved on the body (approximate measurement) that allows the depth of insertion to be controlled, and a Luer lock connector that acts as a handle and ensures a secure connection to the syringe for sperm injection. The two lateral wings, aligned with the tip orifices, allow the device to be correctly oriented during positioning. The transparency of the material allows the successful result of the deposit to be checked at a glance. It must not be used for in vitro fertilisation (IVF), intratubal gamete transfer or embryo transfer.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Model / Family | AINSEWHITE (AINSE family) |
| Reference / SKU | 770219 |
| Type | Soft, centimetre-graduated intrauterine insemination (AI) cannula without handle |
| Outer diameter | 2.0 mm |
| Inner diameter | 1.2 mm |
| Length | 195 mm |
| Tip | Rounded with 2 lateral openings |
| Measurement scale | Centimetre markings on the body (approximate measurement) |
| Connection | Luer lock connector (handle) |
| Orientation | Two lateral wings aligned with the openings |
| Material | Flexible transparent plastic |
| Sterilisation | Beta radiation according to the manufacturer’s IFU (ref. 770219); CE marking 0051. Note: verify the method on the labelling of the received batch. |
| Use | Single-use (disposable) |
| Packaging | Individual sterile pack |
| Presentation | Box of 24 units |
| Quality controls | Embryotoxicity (MEA test) and bacterial endotoxins (LAL test) |
| Indication | Intrauterine artificial insemination with washed sperm |
| Not indicated for | IVF, intratubal gamete transfer or embryo transfer |
4. Equivalences and Cross-References
Reference 770219 has been cross-checked against the manufacturer’s technical data sheet (AINSE range), where it is listed with an outer diameter of 2.0 mm, inner diameter of 1.2 mm, length 195 mm, rounded tip with double lateral orifice, centimetre scale and presentation of 24 units in individual packaging. It is functionally positioned in the category of single-use, soft intrauterine insemination cannulas with double lateral outlet. Below are listed references from other manufacturers verified in official sources (IFU, authorised distributor catalogues and regulatory databases), offered as a functional category comparison and not as interchangeable 1:1 equivalents:
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Gynétics Medical Products | IUI (Uterine Inseminator) | #4220 IUI (code 4220) | Comparable by category (not interchangeable 1:1) | Intrauterine AI cannula with two distal lateral ports, marks on the tube and Luer lock handle with positioner; individual sterile packaging; box of 25 units; sterilisation by irradiation; MEA and LAL tests. Without the continuous centimetre scale or the total softness of the AINSEWHITE body. |
| CooperSurgical | Select IUI® | SM400 | Comparable by category (not interchangeable 1:1) | Effective length 17 cm (total 20 cm), outer Ø 2.1 mm (reduced from 2.6 mm), inner Ø 1.6 mm, closed rounded tip with 2 lateral openings of 1.2 mm, Luer lock connection, polyethylene, graduations 5-10 cm, box of 25 units, sterilisation by ethylene oxide, MEA test greater than 80%. Shorter length than the 195 mm of the AINSEWHITE. |
| Laboratoire CCD | IUI Standard | 120400S | Comparable by category (not interchangeable 1:1) | Outer Ø 2.10 mm, inner Ø 1.65 mm, length 17.5 cm, internal volume 0.40 ml, box of 25 units, HSSA test; comparable for its tip with lateral outlet for semen distribution, although with different calibre and length. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The third-party references indicated are offered as a functional category comparison and require verification of calibre, useful length, tip geometry, connection type and centre protocol before any substitution. Within the same AINSE range, the AINSEGREY (ref. 770220) is the version with steel mandrel of this same cannula.
5. Selection tips and variants of interest
- Measure the depth of the uterine cavity beforehand with a sterile hysterometer and do not exceed that reference during insertion to avoid the risk of perforation.
- Check the integrity of the individual packaging before each use and use the device immediately after opening; do not reuse.
- The AINSEWHITE (770219) is the recommended option when a soft, transparent cannula without mandrel is preferred. If the same cannula with a steel mandrel is desired for guided insertion, choose the AINSEGREY (770220).
- For a configuration with a rigid proximal portion and flexible distal portion of 174 mm, the range offers the AINSEBLUE (770113) with double lateral outlet and the AINSEBLUE T (770408) with open conical tip.
- As an alternative of disposable catheters from the assisted reproduction catalogue itself, the PM-LIFE catheters (CH5 and CH6, 175 mm) cover calibre and guidance needs with introducer or mandrel.
- Always check the sterilisation method and expiry date on the label of the received batch (the manufacturer’s IFU indicates beta rays) and manage the used material as healthcare waste in accordance with current regulations.
For volume orders, annual contracts or specific protocols for your centre, contact our technical-commercial team at Cahnos for special conditions.