Description
1. Commercial Introduction
The BIMONOCYTE (Ref. 770302) is a dual-channel oocyte aspiration and follicular flushing needle in 17G × 330 mm gauge, designed for oocyte retrieval in in vitro fertilisation cycles with maximum safety, precision and respect for the gamete. Its configuration allows aspiration of the cumulus-oocyte complex and flushing of the follicle with culture medium without changing instruments, reducing manipulations, procedure times and stress on the oocyte.
It is supplied in a box of 10 units with individual packaging, being the professional supply solution for fertility clinics, assisted reproduction units and gynaecology practices that require a sterile, single-use device with CE marking 0051. This version without extension connects directly via luer lock to a syringe or suction equipment line.
2. Technical explanation of the equipment and procedure
The BIMONOCYTE needle is a dual-channel device with a single-lumen needle: the first channel is for oocyte aspiration through the needle lumen, and the second for follicular flushing, which runs through an external tube in transparent material connected via a Y-connector that also acts as a handle or grip. It is composed of:
- Echogenic tip with atraumatic bevel: smooth penetration and excellent visibility on the ultrasound scanner monitor, minimising follicular and tissue trauma.
- Blue-tinted tube: protects the oocyte from light and UV rays during aspiration.
- Medical thermoplastic rubber cap: securely connects to the collection tube, sealing the follicular fluid inside.
- Y-connector (handle): connects the needle to the suction and flushing tubes, equipped with 2 universal connectors.
- Transparent follicular flushing line with stopcock: prevents reflux of the flushing fluid.
- Tube clamp: regulates follicular aspiration during the procedure.
- Direct luer lock connection (version without extension) completed with an additional universal adapter for different connection types.
In clinical practice, after preparing the vaginal area and the sterile field, the needle is fixed to the ultrasound probe guide and inserted following the trajectory on the monitor to the follicle, proceeding with gentle aspiration of the cumulus-oocyte complex and follicular flushing. It is a single-use product, sterilised by ethylene oxide (EtO) with CE marking 0051.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference (SKU) | 770302 |
| Brand / family | BIMONOCYTE (no-extension version, direct Luer lock connection) |
| Product type | Dual-channel oocyte aspiration and follicular flushing needle (single-lumen needle) |
| Gauge | 17G (outer diameter ≈ 1.5 mm; transparent luer lock connector) |
| Length | 330 mm |
| Tip | Echogenic with atraumatic sharpening |
| Aspiration channel | Needle lumen + direct Luer lock connection (no extension) |
| Follicular flushing channel | Transparent external tube with anti-reflux stopcock and Y-connector with 2 universal accessories |
| Collection cap | Medical thermoplastic rubber for collection tube |
| Oocyte protection | Blue-tinted tube against UV rays |
| Orientation | Two lateral wings aligned with the tip bevel |
| Gauge identification | Connector colour code: transparent (17G) / azzurro (16G) |
| Sterilisation | Ethylene oxide (EtO) — CE 0051 marking |
| Use | Single-use (non-reusable) |
| Presentation | Box of 10 units, individually packaged |
| Indication | Oocyte aspiration and follicular flushing in assisted reproduction (IVF / OPU) |
BIMONOCYTE / BIMONOCYTE-N family variants:
| Reference (without tube) | Reference (with 80 cm extension) | Gauge | Luer lock connector colour | Presentation |
|---|---|---|---|---|
| 770304 | 770304/TL | 16G × 330 mm | Azzurro (blue) | Box of 10 units |
| 770302 (this product) | 770302/TL | 17G × 330 mm | Transparent | Box of 10 units |
4. Equivalences and Cross-References
Below are listed references from other manufacturers verified against official sources (manufacturer’s technical data sheets and IFU, and GUDID/FDA regulatory database) for the same indication: transvaginal ultrasound-guided oocyte aspiration with follicular flushing (dual-channel) in 17G gauge and length close to 330 mm. None of them are interchangeable 1:1 without technical validation of each centre’s protocol.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cook Medical | EchoTip® Double Lumen Ovum Aspiration Needle (K-OPSD series) | K-OPSD-1733-A-S-US | Comparable by category (not interchangeable 1:1) | 17G × 33 cm (330 mm) with double lumen in needle, 75 cm suction line and 70 cm flushing line (version S); EchoTip® echogenic tip and handle with bevel orientation marker (Cook IFU). |
| CooperSurgical | Wallace® Dual Lumen Oocyte Recovery Set | DNS1733-950 | Comparable by category (not interchangeable 1:1) | 17G × 33 cm (330 mm) with 950 mm suction tube and integrated flushing line; non-coring triple-bevel tip with echogenic marking to the tip; box of 10 units (verified in GUDID 00888937020946). |
| Gynemed | FAS Follicle Aspiration Needle double lumen with flushing | GY-931768LF | Comparable by category (not interchangeable 1:1) | 17G × 32 cm (320 mm), double lumen with flushing and stopcock in the handle; sterilisation by gamma irradiation, CE marking class IIa. Length 10 mm shorter than the BIMONOCYTE. |
| Kitazato | Double Lumen OPU Needle (with aspiration line) | 377350 | Comparable by category (not interchangeable 1:1) | 17G × 35 cm (350 mm), 80 cm suction line and 100 cm flushing line; thin-wall technology and tip with echogenic marking; tested with MEA assay. Length 20 mm longer than the BIMONOCYTE. |
Other reference brands in the category of oocyte needles with follicular flushing (for example, Vitrolife, the FAS line from Gynetics, or Rocket Medical, whose Embryon® double lumen needle is only marketed in 16G gauge: R57610 and R57611) have different lengths, gauges or connection designs and must be compared field by field (gauge, length, tip type, connection, sterility) before any substitution. There is no equivalence table validated by the manufacturer for 1:1 cross-reference with other brands; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Gauge selection: the 17G model (Ref. 770302) offers an excellent balance between stiffness and flow with less trauma; if your protocol requires a larger internal diameter and higher suction flow, consider the BIMONOCYTE 16G version (Ref. 770304), with azzurro connector.
- With tube (version -N) vs. without tube: this reference (770302) connects directly via luer lock to a syringe or equipment line; if you need to integrate into pump suction systems with an 80 cm extension and luer lock connector, consider the BIMONOCYTE-N version (Ref. 770302/TL in 17G and 770304/TL in 16G).
- Dual-channel vs. true double lumen in needle: the BIMONOCYTE performs follicular flushing via an external channel (single-lumen needle); if you need the flushing to run through a second internal lumen of the needle, consider the DOUBLECYTE-N family of double lumen (Refs. 770308/TL in 17G and 770301/TL in 16G).
- Without follicular flushing: if you only require aspiration, the MONOCYTE-N single-lumen series (Ref. 770307/TL in 17G) or the MONOLUME range (Refs. 770311 in 17G and 770312 in 16G) cover that indication more economically.
- Good practice: single-use product, sterile by EtO; use immediately after opening the individual packaging, check the integrity of the packaging and dispose of it in accordance with current legislation. For high volumes or framework agreements, consult our technical-commercial team.





Reviews