Description
1. Introduction
The RIGIDINJECTOR 5 Fr (Ref. 720239) is a rigid disposable uterine injector designed for hysterosalpingography (HSG) and diagnostic procedures of the uterine cavity. Its rigid radiopaque double-lumen catheter allows safe and controlled insertion through the cervical canal, while the distal balloon ensures stable positioning throughout the examination, minimising contrast reflux. A reliable, sterile and single-use solution for assisted reproduction units, gynaecology clinics and radiology services, presented in a box of 10 units with individual packaging.
2. Technical explanation of the equipment and procedure
The RIGIDINJECTOR is designed for the injection of radiopaque contrast media or methylene blue during hysterosalpingography. The set consists of a rigid introducer with a movable positioner (sliding stop) that is adjusted one centimetre below the uterine depth measured by prior hysterometry, and a rigid radiopaque double-lumen catheter: one lumen is intended for contrast injection and the other for inflation of the distal oval balloon made of thermoplastic rubber of 2.5 cc. When inflated, the balloon occludes the internal cervical os, fixes the catheter in position and promotes uterine distension and correct visualisation of the fallopian tubes. The stopcock regulates balloon inflation (2 cc of air according to the manufacturer’s instructions), the anti-reflux clamp prevents fluid leakage during injection and the female Luer-Lock connector ensures a secure connection with the included 2.5 cc syringe. The device is supplied sterile, single-use and individually packaged; it must be used only after hysterometry and under strict medical supervision.
3. Technical Specifications
| Parameter | Specification |
| Device type | Disposable rigid uterine injector for hysterosalpingography |
| Reference | 720239 (RIGIDINJECTOR family: refs. 720225, 720239, 720251) |
| Catheter calibre | 5 Fr (French); outer Ø ≈ 1.67 mm |
| Catheter configuration | Rigid, radiopaque, double-lumen (2 channels) |
| Distal balloon | Oval, thermoplastic rubber, 2.5 cc; recommended inflation: 2 cc of air |
| Introducer | Rigid with movable positioner (sliding stop) |
| Valve / stopcock | Regulates balloon inflation |
| Anti-reflux system | Clamp that tightens the tube |
| Connection | Female Luer-Lock connector for injection of the contrast medium |
| Syringe included | 2.5 cc, for balloon inflation |
| Compatible media | Radiopaque contrast, methylene blue; physiological saline for sonohysterography |
| Application | Hysterosalpingography (HSG) and sonohysterography |
| Sterilisation | Ethylene oxide (EtO); single-use; sterile individual packaging |
| Marking | CE 0051 |
| Presentation | Box of 10 units |
Set components:
| Component | Description |
| Catheter (1) | Rigid radiopaque double-lumen, outer Ø 5 Fr (≈ 1.67 mm), with 2.5 cc distal oval thermoplastic rubber balloon |
| Rigid introducer (2) | With movable positioner / adjustable sliding stop |
| Syringe (3) | 2.5 cc capacity for balloon inflation |
| Valve / stopcock (4) | Regulates balloon inflation |
| Anti-reflux clamp (5) | Prevents reflux of the contrast liquid |
| Female Luer-Lock connector (6) | For injection of the contrast medium |
4. Equivalences and Cross-References
Reference 720239 corresponds to the rigid uterine injector of the RIGIDINJECTOR family and has been verified against the manufacturer’s official technical data sheet (rigid radiopaque double-lumen catheter, 2.5 cc thermoplastic rubber balloon, CE 0051). There is no official equivalence table validated by the manufacturer that cross-references this reference with those of other brands: the references indicated belong to the same functional segment (intrauterine contrast injection with balloon for hysterosalpingography and sonohysterography in 5 Fr calibre), but they should be considered comparable by category and not interchangeable 1:1, since they differ in material, balloon geometry, catheter configuration or set components.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| CooperSurgical | H/S Catheter Set (hysterosonography and hysterosalpingography), 5 Fr, with integrated stylet and insertion sheath | 61-5005 | Comparable by category (not interchangeable 1:1) | Flexible catheter with latex-free balloon (Kraton), 1.5 cc syringe, integrated stylet and placement sheath; flexible configuration compared to the rigid one of the RIGIDINJECTOR and 2.5 cc balloon versus 1.5 cc. Verified in official IFU of CooperSurgical and in GUDID (DI 60888937016477). |
| MedGyn Products | HSG Catheter with wide balloon and rigid insertion sheath, 5 Fr (box of 10) | 022726 | Comparable by category (not interchangeable 1:1) | Disposable latex-free catheter with wide balloon, rigid insertion sheath and inflation syringe; set without stopcock or anti-reflux clamp integrated as an independent regulation system. Verified on MedGyn official website and authorised distributor catalogues. |
| Cook Medical | Cook® Silicone Balloon HSG Catheter, 5 Fr × 30 cm, open tip | J-CHSG-503000 | Comparable by category (not interchangeable 1:1) | Silicone balloon with included syringe and length of 30 cm; without rigid introducer with movable positioner or sliding stop. Verified on authorised distributor website and in FDA device registration (MAUDE). |
| Marina Medical Instruments | HSG-Sono Catheter SureFlex, 5 Fr, 5 cc balloon with 6 cc syringe (box of 10) | MM1-605 | Comparable by category (not interchangeable 1:1) | Flexible latex-free catheter with 5 cc balloon and 6 cc syringe; different balloon volume, set components and configuration (the manufacturer markets it as a style equivalent of the CooperSurgical 61-5005). Verified on Marina Medical official website. |
| Argon Medical Devices | HSG Catheter with concentric latex-free balloon, open distal tip that accepts 0.035\” guidewire, 5.5 Fr × 40 cm (box of 10) | 660005040 | Comparable by category (not interchangeable 1:1) | Soft concentric latex-free balloon and open distal tip with guidewire admission; 5.5 Fr calibre versus 5 Fr and without adjustable sliding stop system. Verified on Argon Medical official website and authorised distributor catalogue. |
Bexen Medical markets an HSG catheter of flexible configuration (radiopaque polyurethane sheath, soft latex-free balloon 3 mm from the tip and included syringe) available in 5 Fr and 7 Fr, but its public catalogue does not publish the reference code: it must be requested directly from the manufacturer. Other brands in the same functional segment are Prince Medical (family PM-CARE) and Bioteque, whose exact equivalences of calibre, length and fixation system must be verified with their technical data sheets.
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders or as a product substitute. Exact equivalences of gauge, length and fixation system must always be verified against the technical data sheets and instructions for use of each brand.
5. Selection tips and variants of interest
RIGIDINJECTOR family (rigid catheter): the range is completed with the RIGIDINJECTOR 6 Fr (Ref. 720225, Ø 2 mm) and the 7 Fr (Ref. 720251, Ø 2.33 mm); the present 5 Fr model (Ref. 720239, Ø ≈ 1.67 mm) is the smallest gauge option, especially indicated for a narrow cervical canal or patients with greater sensitivity while maintaining insertion rigidity.
If greater flexibility is preferred: the SOFTINJECTOR family (Refs. 720226, 720240 and 720250 in 6, 5 and 7 Fr) offers a flexible radiopaque double-lumen catheter with a 2.5 cc balloon. For a semi-rigid system with a steel stylet and double lumen with balloon, consider the Injector Plus (Ref. 730226). For exclusively ultrasound studies of the cavity (sonohysterography) with a smaller gauge, the MININJECTOR 5 Fr (Refs. 770314 and 880314) offer a finer profile; and if active manipulation of the uterus is required in addition to injection, the HANDLIN injector manipulator (Ref. 720199).
Recommendations for use: always perform prior hysterometry to avoid perforation of the uterine fundus, place the catheter 1 cm below the maximum measured depth, inflate the balloon only with 2 cc of air, confirm the contrast medium to be used (water-soluble iodinated for HSG, methylene blue or physiological saline according to protocol) and verify the compatibility of the Luer-Lock connector with the injection route of the equipment. Single-use device: do not reuse, use only if the packaging is intact and destroy after use in accordance with current regulations.





Reviews