We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Open neonatal resuscitation incubator Dixion BabyGuard I-1140-02 (W-1140-02) for intensive care with microcomputer temperature control

Price on request

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

The open neonatal resuscitation incubator BabyGuard I-1140-02 (W-1140-02) from Dixion integrates microcomputer control with three operating modes (preheating, manual and baby) for precise temperature regulation in intensive care. It includes a skin temperature sensor, adjustable heating module, X-ray cassette, APGAR and phototherapy timers, RS-232 interface and an air/oxygen mixer option to ensure a safe and controlled thermal environment for the newborn.

International shipping. Import duties and taxes are payable by the recipient.

Reference
W-1140-02

Description

Open resuscitation incubator for neonatal care

The open resuscitation incubator BabyGuard I-1140-02 (factory reference W-1140-02) from Dixion is an open resuscitation system (Open Reanimation System) designed for neonatal intensive care units (NICU) and delivery rooms that require rapid, continuous and ergonomic access to the newborn without compromising thermal stability. Its microcomputer control and comprehensive standard equipment make it the professional choice for hospitals and clinics seeking highly reliable neonatal technology for the most vulnerable patients.

What it is and how it works

The BabyGuard I-1140-02 integrates three control modes —preheating, manual and baby— managed by a microcomputer that regulates temperature with clinical precision. In baby mode, the servo-control operates through a skin temperature sensor (accuracy of ±0.2 °C) and maintains a control range between 34.5 and 37.5 °C. The heater module can be oriented at 0°, 30° or 60° in two directions, and the bassinet has adjustable tilt in 5 positions (±12°) to facilitate handling of the neonate. The set temperature and the baby’s temperature are displayed separately for clear and precise monitoring of the environment.

The panels surrounding the bassinet can be swung outward for optimal access to the neonate, while the X-ray cassette located under the bassinet allows radiological examinations to be performed without moving the baby. The system incorporates a phototherapy timer for controlling jaundice treatment and an APGAR timer with alerts at 1, 5 and 10 minutes. An over-temperature protection system and multiple failure alarms ensure continuous patient safety.

The equipment can be configured with professional optional units: air and oxygen mixer, low-pressure suction unit, infant resuscitator with T-piece and oxygen administration system, as well as integrated scale and pulse oximetry SpO2. The RS-232 interface allows data transmission and remote control.

Technical specifications

The following table lists the official technical values from the manufacturer Dixion for reference W-1140-02:

Parameter Value
Set type Open resuscitation system (radiant warmer) for neonatal intensive care
Control mode Preheating, manual and baby, by microcomputer
Temperature control range (baby mode) 34.5-37.5 °C
Temperature sensor display range 5-65 °C
Skin temperature sensor accuracy ±0.2 °C
Mattress temperature uniformity ≤2 °C
Heater module angle 0°, 30° and 60° in two directions
Bassinet tilt 5 tilt positions, ±12°
Side panels Swing outward for easy access
X-ray cassette Under the bassinet, without moving the baby
Timers Phototherapy and APGAR (alerts at 1, 5 and 10 minutes)
Phototherapy (optional) Mean bilirubin radiation ≥0.58 mW/cm²; uniformity >0.4; blue light 420-470 nm
Ambient air velocity <0.3 m/s
Power supply 220-230 V / 50-60 Hz (or 110-120 V / 50-60 Hz)
Connectivity RS-232 interface for data transmission
Dimensions 1110 x 625 x 1195 mm / 1270 x 810 x 1120 mm
Safety alarms Over-temperature, deviation, sensor failure, power failure, configuration failure and verification alarm

Professional optional units

Optional unit Specification
Air/oxygen mixer Oxygen concentration 21-100 %, accuracy ±3 %; flow 0-15 L/min configurable in 12 levels
Suction unit Vacuum gauge 0-21 kPa (0-160 mmHg), accuracy ±5 % of full scale; adjustment valve 0-20 kPa
Resuscitator with T-piece Maximum pressure (Pmax) 1-60 cmH2O (factory setting 40 cmH2O); PIP and PEEP adjustable according to flow
Weighing system Optional integrated scale
Pulse oximetry Optional SpO2 system
Disposable sensors Disposable skin temperature sensors

Equivalences and cross-references

The BabyGuard I-1140-02 (W-1140-02) belongs to the Dixion series of open resuscitation systems, together with the W-1140 and W-1145, and is complemented within the Cahnos catalogue by the closed BabyGuard I-1103, I-1107, I-1120 and I-1125 incubators for intensive care. In the clinical concept, it competes directly with radiant warming and open resuscitation systems from other international manufacturers such as Dräger (Babytherm series), GE Healthcare, Fanem or Atom Medical, being functionally interchangeable in its dual role of thermal support, resuscitation and rapid access to the neonate in high-risk deliveries. For budgets and tenders, the technical-commercial department of Cahnos can provide you with a detailed comparison with the reference your centre currently uses.

Selection tips and variants of interest

Assess the type of care your unit provides: if you need integrated resuscitation functions —low-pressure suction, T-piece resuscitator and air/oxygen mixer— the I-1140-02 supports all these optional modules, in addition to pulse oximetry, built-in scale and disposable skin sensors, and offers an optional vertical height adjustment support. If your centre mainly cares for stable neonates that require a closed environment with humidity and oxygen concentration control, consider the closed BabyGuard I-1107 or I-1120 incubators. Complete the equipment with comfort and positioning accessories, such as the gel positioners for the incubator tray available at Cahnos, and always check electrical compatibility (220-230 V / 50-60 Hz) and the available space in the room. For institutional purchases, supply lead times or tender requirements, consult your technical-commercial advisor at Cahnos.

Additional information

Set type

Open resuscitation system / neonatal radiant warmer

Control modes

Preheating, manual and baby by microcomputer

Mattress temperature uniformity

≤2 °C

Heater module angle

0°, 30° and 60° in two directions

Bassinet tilt

5 positions, ±12°

Oxygen concentration

21-100 %, accuracy ±3 %

Air/oxygen mixer flow

0-15 L/min

Phototherapy

Mean bilirubin radiation ≥0.58 mW/cm²; uniformity >0.4; blue light 420-470 nm

Apgar timer

Alerts at 1, 5 and 10 minutes

Power supply

220-230 V / 50-60 Hz (or 110-120 V / 50-60 Hz)

Dimensions

1110 x 625 x 1195 mm / 1270 x 810 x 1120 mm

Connectivity

RS-232 interface

Optional accessories

Integrated scale, pulse oximetry SpO2, disposable skin sensors

Reviews

There are no reviews yet.

Be the first to review “Open neonatal resuscitation incubator Dixion BabyGuard I-1140-02 (W-1140-02) for intensive care with microcomputer temperature control”

Your email address will not be published. Required fields are marked *