We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

GREEN fibre-optic (F.O.) laryngoscope blade Miller No. 00 OXY – Premature, austenitic stainless steel, autoclavable (Ref. 34460) | SKU GM34460

55,10 €

Reusable laryngoscope blade (blade) GREEN fibre-optic (F.O.) with straight Miller profile No. 00 OXY, specifically designed for orotracheal intubation in premature patients. Equipped with a detachable fibre-optic light guide that ensures maximum light transmission and bright, stable illumination of the glottis. Manufactured in non-magnetic, oxidation-resistant austenitic stainless steel with a matt anti-reflective finish. Compatible with standard Green handles according to BS EN ISO 7376 standard and autoclavable up to 134 °C for 5 minutes (up to 2,000 cycles), also allowing plasma sterilisation. Class I medical device with 3 years of manufacturer’s warranty. Reference 34460 (SKU GM34460). For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM34460

Description

1. Commercial Introduction

The “GREEN” fibre optic Miller-type No. 00 OXY laryngoscope blade is the reference solution for direct laryngoscopy and orotracheal intubation in premature patients, within the GREEN laryngoscope series. Its fibre optic illumination system with detachable light guide offers maximum light transmission, with a bright, stable beam that allows clear visualisation of the glottis even in extremely small and delicate anatomies.

Made from austenitic stainless steel, non-magnetic and corrosion-resistant, it combines robustness, durability and complete safety in reprocessing. It is the professional choice for anaesthesiology, neonatology, paediatrics, emergency, neonatal critical care units and operating theatre services seeking reusable, reliable instruments compatible with the most widely used Green standard handles on the European market.

2. Technical explanation of the equipment and procedure

Direct laryngoscopy with a Miller-type blade is the classic straight-profile technique for endotracheal intubation: the straight blade directly lifts the epiglottis, exposing the glottis and facilitating passage of the endotracheal tube. The No. 00 OXY size is specifically designed for the reduced anatomy of the premature patient, where an unsuitable blade would compromise visualisation and increase the risk of injury.

This blade incorporates a high-quality fibre optic (F.O.) bundle with detachable light guide: light is conducted from the handle to the distal end of the blade, concentrating illumination at the exact point of visualisation and avoiding the loss of brightness typical of conventional systems with a proximal bulb. The matt finish reduces reflections on tissues and improves contrast, while the non-magnetic material and compatibility with moist heat and plasma sterilisation allow safe reprocessing in the sterilisation department.

3. Technical Specifications

Reusable fibre optic laryngoscope blade from the “GREEN” FIBRE OPTIC BLADES line, belonging to the GREEN LARYNGOSCOPES laryngoscope series.

Technical features

Characteristic Specification
Manufacturer reference (SKU) 34460
Blade model Miller (MILLER) No. 00 OXY
Target population Premature
Blade type Fibre optic (F.O.) with detachable light guide, matt anti-reflective surface
Material Austenitic stainless steel (corrosion-resistant, non-magnetic)
Compatibility Green standard handles to BS EN ISO 7376
Sterilisation Autoclavable up to 134 °C for 5 minutes (up to 2,000 cycles); compatible with plasma sterilisation
Compatible power sources AA and C batteries, or 2.5 V and 3.5 V rechargeable batteries; handles with xenon/halogen or LED bulbs
Warranty 3 years

Product data

Value Value
Manufacturer GIMA
Manufacturer reference 34460
Sales unit 1 pc
Device type Medical device (medical device)
Device class I
CND Z12021003
GMDN 46827
EAN 8023279344608

Advantages certified by the manufacturer

  • Maximum light transmission thanks to durable, high-quality optical fibres.
  • Blades specifically designed to facilitate intubation.
  • Matt finish to reduce reflections.
  • Autoclavable up to 134 °C for 5 minutes; blades autoclavable up to 2,000 cycles.
  • Compatible with plasma sterilisation.
  • Compatible with Green standard handles according to BS EN ISO 7376.
  • Made from austenitic stainless steel, rust-proof.
  • Long-lasting: offers a 3-year warranty.
  • Non-magnetic blade.

4. Equivalences and Cross-References

This blade belongs to the international Green System standard (BS EN ISO 7376), and is therefore interchangeable at connection level with reusable laryngoscope handles that comply with this same standard, regardless of their battery configuration or light source (AA or C batteries, 2.5 V and 3.5 V rechargeable batteries, xenon/halogen or LED bulbs).

Within the catalogue itself, the Miller straight-profile fibre optic blade series from the same GREEN family includes sizes No. 00 OXY (34460, this reference, premature), No. 0 (34461, newborns), No. 1 (34462, infants), No. 2 (34463, children) and No. 3 (34464, adults). For curved profiles in the neonatal and paediatric population, the McIntosh F.O. series (refs. 34469-34474) is a complementary alternative within the same family. No manufacturer-validated 1:1 equivalence table is available against third-party codes (e.g. Heine, Penlon, Riester or KaWe); before replacing a blade from another brand, the connection fit, profile and size must be verified according to BS EN ISO 7376 and the reference checked with the Cahnos technical department before use in tenders.

5. Selection tips and variants of interest

The blade size should be chosen according to the patient’s age and anatomy: size No. 00 OXY (this reference) is indicated for premature infants, No. 0 (ref. 34461) for newborns, No. 1 (ref. 34462) for infants, No. 2 (ref. 34463) for children and No. 3 (ref. 34464) for adult patients.

To complete the laryngoscope, combine this blade with a Green standard handle (BS EN ISO 7376) from the GREEN range: the 2.5 V handles accept standard or rechargeable batteries, and the series offers xenon/halogen or LED light sources in 2.5 V and 3.5 V versions, with AA or C batteries. Always check the connection fit before each procedure and follow the recommended sterilisation protocol (autoclave at a maximum of 134 °C for 5 minutes, with a limit of 2,000 cycles) to extend the instrument’s service life and maintain the warranty. For complete sets, airway trolley configurations or tenders, contact the technical-commercial department of Cahnos:. For large orders you can request a quote.

Additional information

Manufacturer reference

34460

Blade model

Miller No. 00 OXY

Target population

Premature

Blade type

Fibre optic (F.O.) with detachable light guide

Material

Austenitic stainless steel (corrosion-resistant, non-magnetic)

Finish

Matt, anti-reflective

Compatibility

Standard Green BS handles EN ISO 7376

Sterilisation

Autoclavable up to 134 °C for 5 minutes (up to 2,000 cycles); compatible with plasma sterilisation

Lighting

Detachable fibre optic light guide; light source in the handle (AA/C batteries or 2.5 V and 3.5 V rechargeable batteries)

Magnetism

Non-magnetic

Warranty

3 years

CND code

Z12021003

GMDN code

46827

EAN

8023279344608

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEspañol PDF · English PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “GREEN fibre-optic (F.O.) laryngoscope blade Miller No. 00 OXY – Premature, austenitic stainless steel, autoclavable (Ref. 34460) | SKU GM34460”

Your email address will not be published. Required fields are marked *