Description
1. Introduction
The disposable SpO2 catheter is the optional pulse oximetry accessory designed for the pulse oximeter Ref. 35048. Its single-use design, valid for both neonatal and adult patients, makes it the most hygienic solution for monitoring vital signs in outpatient clinics, emergency departments, primary care and hospitalisation services: a new catheter per patient that eliminates sensor disinfection and minimises the risk of cross-contamination.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin through the differential absorption of red and infrared light across the capillary bed. This disposable catheter integrates the emitter and photodetector in a single element placed on the patient’s finger; the captured signal is processed by the pulse oximeter Ref. 35048, which displays the SpO2 value and pulse rate. As a single-use sensor, it is removed and discarded after each patient, always maintaining a clean contact point and ensuring measurement reliability even in high-turnover healthcare environments.
3. Technical Specifications
Single-use pulse oximetry sensor indicated for neonatal and adult populations, compatible with the pulse oximeter Ref. 35048. As a disposable accessory, it requires no cleaning or reprocessing between patients.
| Value | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| EAN | 6945040110286 |
Available references
| Reference | Detail |
|---|---|
| 35044 | Disposable SpO2 catheter (single-use) neonatal/adult – optional accessory |
| 35048 | Compatible pulse oximeter |
| Sales unit | 1 pc |
4. Equivalences and Cross-References
Reference 35044 is the original accessory for the pulse oximeter 35048. No reliable sources have been found for a manufacturer-validated equivalence table confirming the 1:1 interchangeability of this disposable catheter with SpO2 sensors from other manufacturers (Nonin, Masimo, Nellcor, etc.), since compatibility depends on the connector type and the electronic protocol of each device. It is always recommended to verify the connector and sensor specifications with our technical department before considering replacement with a catheter from another brand, especially in tenders or maintenance contracts.
5. Selection tips and variants of interest
Confirm that your device corresponds to the pulse oximeter Ref. 35048 before placing the order. This catheter is the indicated option when maximum hygiene and intensive use with patient rotation are prioritised. If your service prefers reusable sensors to reduce the cost per use with proper cleaning between patients, the same family offers the reusable adult replacement catheter (ref. 35049) and the compatible reusable paediatric and neonatal catheters (refs. 35054 and 35055). To complete your pulse oximetry fleet or configure volume orders, contact our technical-commercial team. For large orders you can request a quote.





Reviews
There are no reviews yet.