Description
1. Commercial Introduction
The reusable neonatal SpO2 pulse oximeter catheter (reference 35055) is the optional measurement accessory designed for continuous monitoring of blood oxygen saturation and pulse rate in newborns. A European benchmark in medical equipment, this catheter has been designed as a complement to the Ref. 35048 and 35111 devices and is ideal for neonatology, NICU, maternity, delivery room and paediatrics services.
As a reusable accessory, it helps optimise the cost per patient in high-turnover environments, maintaining reliable monitoring with proper cleaning and maintenance between uses. For large orders, you can request a quote: contact the technical-commercial team at Cahnos for availability and B2B terms.
2. Technical explanation
Pulse oximetry is a non-invasive technique that measures the functional oxygen saturation of arterial haemoglobin by spectrophotometry. The catheter emits light at two wavelengths (red and infrared) through the neonate’s vascular bed (usually the foot or hand), and the device calculates, from the differential absorption of light associated with blood flow, the SpO2 value and pulse rate in real time.
This reusable neonatal catheter is specifically designed to fit the anatomy of the smallest patient, ensuring a stable coupling and a quality plethysmographic signal even in low-birth-weight neonates. It connects directly to the compatible device and is valid for units with a serial number from 25050500001.
3. Technical Specifications
3.1 Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35055 |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040110262 |
3.2 Available references
| Reference | Description | Sales unit |
|---|---|---|
| 35055 | Reusable neonatal SpO2 catheter for 35048 and 35111 (from SN 25050500001) – optional | 1 pc |
3.3 Characteristics and compatibility
| Parameter | Specification |
|---|---|
| Catheter type | Reusable neonatal pulse oximeter (SpO2) catheter |
| Patient population | Neonatal |
| Compatible equipment | Ref. 35048 (OXY-55) and Ref. 35111 |
| Valid from serial number | SN 25050500001 |
| Use | Reusable (optional accessory) |
4. Equivalences and Cross-References
Reference 35055 is the specific code for this reusable neonatal SpO2 catheter intended for the 35048 and 35111 devices. The manufacturer does not declare an official equivalence table that would allow this catheter to be replaced by sensors from other brands on a 1:1 interchangeable basis, so it must not be replaced without prior technical validation from the Cahnos department.
Within the catalogue itself, reusable SpO2 catheters of a similar nature are identified for other devices in the range, such as the Y-type neonatal catheter (ref. 35099) and the rubber paediatric catheter (ref. 35097), both for the Ref. 35095 monitor. Before any replacement, always verify the compatibility of the connector and the communication protocol with the exact brand and model of your device.
5. Selection tips and variants of interest
Select this catheter when you need to replace or expand the pulse oximetry sensor of your Ref. 35048 (OXY-55) or 35111 device with a serial number from 25050500001, prioritising the monitoring of neonatal patients in neonatology, NICU, maternity or paediatrics services.
As a reusable accessory, plan the rotation and maintenance following the manufacturer’s instructions to ensure measurement accuracy for each patient. For institutional orders, centre allocations or standardisation of accessories, contact the technical-commercial department at Cahnos: we will advise you on the appropriate spare part for each device.






Reviews