Description
The BabyGuard I-1140 neonatal incubator (factory reference W-1140) from Dixion is a radiant heat system designed for neonatal intensive care units (NICU), delivery rooms and neonatology services that require rapid, continuous and ergonomic access to the newborn without compromising thermal stability. Its microcomputer control, integrated phototherapy lamps and full standard equipment make it the professional choice for hospitals and clinics seeking highly reliable neonatal technology for the most vulnerable patients.
What it is and how it works
The BabyGuard I-1140 (W-1140) integrates a servo-control of air and skin temperature managed by microcomputer, with manual or automatic control via a membrane touch panel. The LED indicator shows at all times the actual temperature and the set temperature of the air and skin, allowing clear and precise monitoring of the neonate’s thermal environment. The built-in “radiant heat” type heater provides uniform heat distribution, with a radiation head tiltable at 0°, 30° and 60° and 360° rotation to orient the focus according to the patient’s position. The bassinet allows an adjustable tilt from 0° to 10° to facilitate handling and access to the newborn.
The equipment incorporates integrated phototherapy lamps for the treatment of neonatal hyperbilirubinaemia (jaundice) directly over the work area, as well as an X-ray film cassette beneath the work area that allows radiological studies to be performed without moving the baby. The system offers 4 alarm options —power off, transducer failure, temperature deviation, temperature rise and internal failure— that ensure continuous patient safety. The infusion stand and shelves for additional equipment complete the specification, providing functionality and organisation to the work environment.
Technical specifications
The official technical values from the manufacturer Dixion for reference W-1140 are listed below:
| Parameter | Value |
|---|---|
| Set type | Infant radiant warmer (open incubator) for neonatal intensive care |
| Control mode | Manual or automatic temperature control via microcomputer and touch panel |
| Servo-control | Air and skin temperature |
| Temperature control range | 25–37 °C |
| Indicator | LED of actual and set air and skin temperature |
| Heater | Built-in, ‘radiant heat’ type |
| Bassinet tilt | 0–10° |
| Radiation head tilt | 0°, 30°, 60° with 360° rotation |
| Phototherapy | Built-in phototherapy lamps |
| X-rays | X-ray film cassette under the work area |
| Alarms | 4-alarm option: power off, transducer failure, temperature deviation, temperature rise and internal failure |
| Power supply | 220–230 V / 50–60 Hz (110–120 V version available) |
| Dimensions | 1120 x 710 x 1800 mm |
| Included accessories | Infusion stand and shelves for additional equipment |
Equivalences and cross-references
The BabyGuard I-1140 (W-1140) belongs to Dixion’s series of radiant heat and open resuscitation systems, together with the W-1140-02 (I-1140-02) and the W-1145 (I-1145), and is complemented within the Cahnos catalogue by the closed BabyGuard incubators I-1103, I-1107, I-1120 and I-1125 for intensive care. In the clinical concept, it competes directly with radiant warming systems and thermal resuscitation cots from other international manufacturers such as Dräger (Babytherm series), GE Healthcare, Fanem or Atom Medical, being functionally interchangeable in its role of thermal support and rapid access to the neonate in high-risk deliveries. For budgets and tenders, the technical-commercial department of Cahnos can provide you with a detailed comparison with the reference your centre currently uses.
Selection tips and variants of interest
Assess the type of care your unit provides: if you need integrated resuscitation functions (air/oxygen mixer, low-pressure suction unit, T-piece resuscitator, APGAR timer), consider the advanced versions of the same series, such as the BabyGuard I-1140-02 (W-1140-02) or the I-1145 (W-1145). If your centre mainly cares for stable neonates that require a closed environment with humidity and oxygen concentration control, the closed BabyGuard incubators I-1107 or I-1120 are the recommended alternative. Always verify electrical compatibility (220–230 V / 50–60 Hz) and the space available in the room (1120 x 710 x 1800 mm), and complete the equipment with comfort accessories such as gel positioners for the incubator tray available at Cahnos. For institutional purchases, supply lead times or tender requirements, consult your technical-commercial advisor at Cahnos.