Description
1. Commercial Introduction
The 3M™ RED DOT™ 2248-50 monitoring electrodes (reference 33299) are single-use disposable consumables, specifically designed for continuous electrocardiographic monitoring in paediatric patients. Their non-woven fabric support with micropore tape backing provides a gentle, breathable fixation that is kind to children’s sensitive skin, without compromising the signal stability that characterises the 3M RED DOT™ range.
They are supplied in a box of 50 units, a practical format for paediatrics, neonatology, PICU, emergency departments and paediatric cardiology clinics, as well as for ambulatory monitoring units. As an original 3M electrode, it guarantees the reliability and trace homogeneity characteristic of one of the most recognised families of surface electrodes on the market.
2. Technical Explanation
The monitoring electrode acts as an interface between the patient’s skin and the recording equipment: it captures the electrical activity of the heart and transmits it with the least possible distortion. Trace quality depends on three key factors: adhesion (the electrode must remain fixed throughout monitoring), conductivity (low skin-electrode contact impedance) and stability against patient movement.
This model incorporates a non-woven fabric support with micropore tape backing, a breathable and flexible adhesion system that adapts to the thoracic contour of the paediatric patient and minimises irritation on delicate skin. The single-use electrode guarantees hygiene and prevents cross-contamination between patients: each monitoring session starts with a new, ready-to-use electrode, with no skin preparation beyond prior cleaning and drying.
3. Technical Specifications
Paediatric ECG monitoring electrode with the following main features:
| Characteristic | Value |
|---|---|
| Type | Disposable, single-use monitoring electrode |
| Code 3M | 2248-50 |
| Diameter | Ø 4.5 cm |
| Support material | Non-woven fabric with micropore tape backing |
| Population | Paediatric |
| Application | Paediatric ECG monitoring |
| Use | Single-use, disposable |
| Presentation | Box of 50 units |
Product data
| Value | Value |
|---|---|
| Brand | 3M |
| Sales unit | Box of 50 units |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
Available references
| Reference / Code | Origin | Description |
|---|---|---|
| 33299 | SKU | 3M RED DOT 2248-50 ELECTRODES – Ø 4.5 cm |
| GM33299 | SKU Cahnos | 3M RED DOT 2248-50 electrodes – box of 50 units |
| 2248-50 | Code 3M | RED DOT™ family – paediatric monitoring electrode with micropore |
Note: technical data comes from the manufacturer’s official catalogue; verify the labelling of the supplied batch before use in tenders.
4. Equivalences and Cross-References
Reference 33299 is the manufacturer’s official code for this 3M RED DOT 2248-50 electrode. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands; any comparison between manufacturers should be understood as comparable by category (disposable monitoring electrode with non-woven support, for paediatric population) and never as interchangeable without verification.
Within the 3M™ RED DOT™ family itself, the reference code is 2248-50 (Ø 4.5 cm). As variants of the same monitoring family in non-woven fabric, the 3M RED DOT 2238 and 2239 electrodes (Ø 6 cm, soft cloth and micropore support respectively, adult format) can be cited, recognised under references 33296 and 33297. Before any substitution, a field-by-field check must be carried out: diameter, support material, target population and compatibility with the monitor lead cable connector.
5. Selection tips and variants of interest
- Paediatric population: this Ø 4.5 cm electrode with micropore is the ideal option for monitoring paediatric patients. For adults, consider the larger surface area electrodes from the same RED DOT™ range, such as models 2238 and 2239 (Ø 6 cm).
- Monitoring duration: for prolonged use over several days, consider the foam series electrodes with adhesive gel from the RED DOT™ family (codes 2228 and 2244), which have greater staying power on the skin.
- Equipment connection: verify the connector type and lead cable of your monitor or ECG machine; if a 4 mm adapter is required, consult the 2228BA variant of the same RED DOT™ family.
- Skin preparation: clean and dry the application area (paediatric chest) before placing the electrode, avoiding creams, hair or oily residues to optimise contact impedance and avoid repeats due to poor signal.
- Storage: single-use disposable product; keep boxes closed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet is opened or damaged.
- Supply: the box of 50 units is designed for consumption in clinics and paediatric units; for full supplies or tenders, contact the technical-commercial department of Cahnos.





Reviews
There are no reviews yet.