Description
1. Commercial Introduction
The 23 x 34 mm seal-type monitoring and ECG electrode (SKU 590013) is the reference consumable for resting electrocardiograms and patient monitoring with crocodile-clip leads and forceps. Its silicone body with pre-gelled solid gel combines firm, comfortable adhesion with stable signal transmission, reducing repeats due to poor signal and streamlining the professional’s daily work.
Supplied in a bag of 100 units with a minimum sales unit of a box of 2,000 units, it is the high-turnover solution for cardiology clinics, emergency departments, ICUs, occupational medicine units, patient transport and stress ECG services that need a reliable, hypoallergenic electrode with excellent cost per procedure.
2. Technical explanation
This electrode is a single-use surface electrode of the seal or stamp type, designed to capture the electrocardiographic signal through a low-impedance skin-electrode contact. Connection is made via a tab (TAB) that is secured with the crocodile clip (alligator) of the patient lead, the most common standard in resting electrocardiographs and monitors with clip leads: it requires no snap or adapters, just press the jaw onto the tab.
The silicone backing provides flexibility and comfort, adapting to the thoracic contour without irritation, while the solid conductive gel keeps conductivity and adhesion constant throughout the recording, with no risk of leakage or need for additional gel. The assembly, latex-free and single-use, guarantees hygiene and absence of cross-contamination between patients, and its radiolucent construction allows the electrode to remain in place during radiological checks without interfering with the image.
3. Technical Specifications
Main features (product data)
| Type | Disposable monitoring and ECG electrode, stamp / sticker type with tab for crocodile clip |
| Material | Silicone backing |
| Measurements | 23 x 34 mm |
| Presentation | Bag of 100 units |
| Minimum sales unit | Box of 2,000 units (20 bags of 100 units) |
Supplementary technical data (verified in the manufacturer’s technical documentation)
| Sensor | Ag/AgCl (SSC – silver/silver chloride) for stable signal and low distortion |
| Gel | Pre-gelled solid conductive gel, adhesive and low impedance |
| Connection | Tab (TAB) compatible with crocodile-type (alligator) clips |
| Radiolucency | Yes: suitable for radiological checks without removing the electrode |
| Population | Adult (standard size 23 x 34 mm) |
| Use | Disposable, single patient, non-sterile |
| Latex | Latex-free |
| Applications | Resting ECG, monitoring, tests with crocodile clip leads |
| Storage | In sealed packaging, in a dry, cool place; observe the expiry date. |
| Classification | Medical device with CE marking |
4. Equivalences and Cross-References
SKU 590013 is the Cahnos distribution code for this seal-type ECG electrode with tab connection for crocodile clip. After cross-checking official manufacturer catalogues and authorised technical distribution, it is confirmed that the 23 x 34 mm format with TAB tab, solid gel and alligator connection is a widely shared market standard; however, there is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with codes from other brands. The following references are comparable by category (not 1:1 interchangeable) and must be verified field by field (dimensions, backing, gel, sensor and connection) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GIMA S.p.A. (Italy) | Disposable pre-gelled stamp electrodes for resting ECG, adult, crocodile clip connection | 33341 | Comparable by category (not interchangeable 1:1) | Code verified in the official GIMA catalogue: same 34 x 23 mm format, solid gel, TAB shape and alligator connection, latex-free, bag of 100 units. It matches the analysed reference in dimensions, gel and connection type; it is recommended to verify labelling, sensor and batch before substituting. |
| 3M / Solventum | Red Dot™ Resting EKG Electrode series 2300, tab style, adult, radiolucent | 2330 (stock 3M 512994) | Comparable by category (not interchangeable 1:1) | Code verified in the Solventum catalogue and authorised technical distribution: resting electrode with tab connection, conductive adhesive gel, radiolucent and pack of 100 units. The backing differs (foam/fabric versus silicone), as do the dimensions and the sensor; confirm the technical data sheet before substituting. |
| CNSAC | TAB electrode 23 x 34 mm for neurophysiology and ECG | TAB 23×34 (pack of 100 units) | Comparable by category (not interchangeable 1:1) | Code verified in the official CNSAC MedShop store: same 23 x 34 mm dimensions and tab (TAB) connection, latex-free, presentation of 100 units. Also indicated for EMG, PSG, ENG and EOG; confirm gel, sensor and adhesive against the analysed reference. |
There is no manufacturer-validated equivalence table authorising the 1:1 substitution of this reference with codes from other brands; consult the technical department before use in tenders. As homologous families in the sector that should be evaluated with their technical data sheet in hand, mention may be made of the resting electrodes with tab connection from Solventum (Red Dot), the Medi-Trace series from Kendall (Cardinal Health), the tab electrodes from Skintact (Leonhard Lang) and the disposable ECG electrode ranges from Ambu, GIMA, Medke and other market suppliers, always pending code confirmation against an official source and verifying one by one dimensions, backing, sensor, gel and connection type.
5. Selection tips and variants of interest
Check your lead terminal: this electrode is designed for patient leads with a crocodile clip (alligator) that attaches over the tab (TAB). If your installed base uses snap or 4 mm banana leads, you will need to combine the electrode with the appropriate adapter or choose an electrode with the corresponding configuration.
Select according to the recording: the seal format with solid gel of 23 x 34 mm is the ideal option for resting ECG and monitoring with clip leads in adult patients. For long-duration Holter recordings or continuous monitoring, it is advisable to consider larger-surface electrodes with a central snap from the same range, adapting the choice to the service protocol.
Radiology without electrode removal: as this is a radiolucent electrode, it can remain in place during imaging checks, avoiding repeats and patient discomfort; always verify the manufacturer’s indication for your service.
Skin preparation: to optimise contact impedance, clean and dry the application area (chest), avoiding creams, hair or gel residue from previous recordings; on oily or very sweaty skin use a preparatory gel beforehand.
Storage and replenishment: keep the bags closed in a dry, cool place, rotate stock on a FIFO basis and respect the expiry date; as a single-use, high-turnover consumable, maintain a minimum stock per monitoring station. For volume orders, tenders or bids, contact the technical-commercial department of Cahnos indicating the type of lead in your installed base to confirm compatibility and a formal quotation.





Reviews