Description
1. Commercial Introduction
The NM 50 RFI electrode (reference Cahnos 13628) is the disposable consumable of choice for cardiac monitoring and electrocardiogram acquisition in adult patients. Its circular foam format of Ø 50 mm, solid conductive gel and medical-grade adhesive ensure firm, comfortable fixation with stable signal transmission from the start of recording. Supplied in a bag of 40 units and with a minimum sale unit of a box of 800 units, it is the high-turnover solution for cardiology departments, ICUs, emergency rooms, hospital wards and purchasing centres seeking a reliable electrode with excellent cost per procedure.
2. Technical Explanation
A surface ECG electrode acts as an interface between the patient’s skin and the monitor or electrocardiograph: it captures the heart’s electrical activity and transmits it with minimal distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study), conductivity (low skin-electrode contact impedance) and stability against movement.
The foam support (medical foam) is flexible and lightweight: it protects the gel and sensor, adapts to the chest contour and maintains its integrity during resting recordings and continuous monitoring. The solid conductive gel (polymerised hydrogel) retains its aqueous content, does not dry out during prolonged recordings and eliminates the mess of liquid gels, maintaining stable conductivity over time. It is a non-irritant, non-sensitising and latex-free composition that meets the performance requirements of the voluntary standard ANSI/AAMI EC 12 for disposable ECG electrodes.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 13628 |
| Model / family | NM 50 RFI (Top Trace Monitoring line) |
| Type | Conventional electrode for monitoring and ECG |
| Material | Foam (medical foam) with solid gel |
| Diameter | Ø 50 mm (circular format) |
| Sensor material | Ag/AgCl |
| Connection type | Snap-type press stud (confirm with batch data sheet) |
| Presentation | Bag of 40 units |
| Minimum sales unit | Box of 800 units |
| Application | Cardiac monitoring and electrocardiograms |
| Advantages | Excellent adhesion, precise signal, comfortable for the patient |
| Adhesive | Medical grade (non-sensitising acrylic copolymer) |
| Composition | Non-irritant, non-sensitising, non-cytotoxic; latex-free |
| Use | Clinical and hospital use; single-use product |
| Reference standards | ANSI/AAMI EC 12:2000/(R)2005; Class I medical device with CE marking |
Note: material, gel and presentation data come from the distributor’s technical documentation; confirm with the supplied batch data sheet the exact connector type and electrical values (offset voltage, AC impedance at 10 Hz) for use in tenders.
4. Equivalences and Cross-References
Reference 13628 (model NM 50 RFI) is the Cahnos distribution code for this adult circular foam electrode with solid gel; there is no manufacturer-validated equivalence table authorising 1:1 cross-referencing with third-party brands. The following references share the same category (disposable foam ECG electrode with solid gel/adhesive hydrogel and button connection for adult monitoring) and have a confirmed code in the manufacturer’s official catalogue or GUDID regulatory database. They are classified as comparable by category, not interchangeable 1:1: field-by-field verification (diameter, geometry, gel type and connector position) must be carried out before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| 3M / Solventum | Red Dot™ Monitoring Electrode with foam tape and sticky gel (solid adhesive gel) | 2560 (also V2560-5) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID (DI 00707387789305) and 3M official catalogue: foam, solid adhesive gel, snap connection, Ag/AgCl sensor and prolonged use validated up to 5 days. Differs in geometry: rectangular format of 4 × 3.5 cm versus circular Ø 50 mm. Verify contact surface and cable fit before substituting. |
| Cardinal Health (Kendall™) | Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) | 31013926 (series 530) | Comparable by category (not interchangeable 1:1) | Code confirmed in Cardinal Health official catalogue and authorised technical distribution: foam with conductive adhesive hydrogel (solid gel), snap connection, indicated for stress, Holter and diaphoretic monitoring, compliant with ANSI/AAMI EC 12. Teardrop shape of approx. 44 mm versus circular Ø 50 mm. Verify geometry and adhesive of the batch before substitution. |
| Ambu (Denmark) | BlueSensor™ R (adult, foam, snap) | R-00-S / R-00-S/25 | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID (05707480022205) and Ambu’s official catalogue: foam with Ag/AgCl sensor and offset snap connector, approx. 57 × 48 mm. Key difference: highly conductive wet gel versus the solid gel of this reference, and off-centre connector versus the usual centred position. Suitable for stress testing and monitoring; check gel type and connector fit before replacement. |
| FIAB (Italy) | F9060 – oval foam and solid gel electrode for adult | F9060 | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue and authorised distribution: foam, solid gel, Ag/AgCl sensor and snap connection, indicated for rest, long-term monitoring, stress and Holter. It differs in geometry: oval format of 48 × 50 mm and presentation of 50 units/bag with a box of 1,200 units. It is the closest alternative as it matches the backing, gel type and effective diameter; check connector fit before replacement. |
| Leonhard Lang (Skintact®) | FS-TB1 – foam electrode with solid Aqua-Tac™ gel and removal tab | FS-TB1 | Comparable by category (not interchangeable 1:1) | Code confirmed in Leonhard Lang USA’s official catalogue and authorised technical distribution: foam, solid adhesive Aqua-Tac™ gel, Ag/AgCl sensor and snap connection, 50 × 54 mm with a lift tab for easy removal. It differs in geometry (tabbed format versus the circular Ø 50 mm) and in presentation (30 units/bag, box of 1,500 units). Check contact surface and connector fit before replacement. |
There is no equivalence table validated by the manufacturer that authorises 1:1 replacement between monitoring electrode brands: geometry, gel type (solid or liquid), active surface and connector position affect adhesion and signal quality. Any replacement must be validated against the technical data sheet and instructions for use from the electrode and monitoring system manufacturer, checking one by one diameter, backing, gel and connector; consult the technical department at Cahnos before use in tenders.
5. Selection tips and variants of interest
Solid gel, the choice for stable recordings: the solid gel in this reference maintains conductivity without liquid residue and is ideal for continuous monitoring and resting ECG. If your department prioritises immediate signal capture during stress testing, consider the versions of the same family with liquid gel, such as the ST 50 RLI Ø 50 mm (ref. 0590024).
Variants of the same family at Cahnos: the ST 50 RFI Ø 50 mm electrode with solid gel for Holter and stress (ref. 0590028) shares backing, gel and diameter with this reference; the radiolucent RT 50 RFI electrode (ref. 0590022) and the multifunction F 50 S BLUE (ref. 15843) add a translucent radiolucent snap suitable for X-ray and MRI. For banana connectors, the NM 2844 FBI (ref. 0590025) is available; and for paediatric patients, the NM 30 RFI Ø 30 mm (ref. 0590016). All share foam and gel technology but differ in diameter, geometry or connection: adapt the choice to your monitor fleet and the connector type of your patient cables.
Check the connection: confirm the connector type (snap press stud, clip or banana) of the patient cable in your monitor fleet and contact us if you need adapters. Preparation and storage: clean and dry the skin before application, avoid creams or oily residues and keep the bags closed in a dry, cool place, rotating stock on a FIFO basis and respecting the expiry date: the solid gel can lose conductivity if the packaging is opened or damaged. For volume orders, complete supplies or tenders, contact the technical-commercial department at Cahnos indicating the model of your monitor fleet and the type of connection.