Description
1. Commercial Introduction
Ensure safe cardiac care for the smallest patients with this pair of radiotransparent paediatric defibrillator electrodes with internal cable (reference F7750P), a high-reliability consumable compatible with the most widely used Philips defibrillator-monitor families in hospital and emergency settings: CodeMaster 100, XE, XL and XL+ (including factory references M2475B, M1724A, M1723A/B and M1722A/B), HeartStart 4000, XL/XLT, MRx, Efficia DFM100 and HeartStart Intrepid. Designed for emergency departments, paediatric ICU, ambulances, operating theatres and haemodynamics, it combines the advantages of the radiotransparent series — artefact-free imaging control — with the robustness of the integrated 100 cm internal cable, which maintains a stable connection throughout resuscitation. A cost-optimised solution, compliant with EU Regulation 2017/745 (class IIb) and latex- and phthalate-free.
2. Technical explanation of the equipment and procedure
Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers therapy and monitors the response. This paediatric model allows transthoracic external defibrillation, synchronised cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring (up to 24 h), adapted to paediatric physiology (children under 8 years or weighing less than 25 kg). Its radiotransparent condition — in both the electrode and the cable — prevents artefacts in X-rays, CT scans and image-guided studies, so it can remain in place during examination without interrupting monitoring or therapy. The low-impedance conductive adhesive gel on medical foam with a metallic film ensures uniform current distribution and a reliable signal with a reduced pacing threshold. They are single-use: they must be replaced after each procedure or upon reaching the expiry date printed on the packaging, and placed according to the anatomical diagrams (sternal and apical positions) on the sachet.
3. Technical Specifications
| Reference Cahnos (SKU) | F7750P |
| Product type | Pair of multifunction paediatric defibrillator electrodes, radiotransparent, with internal cable |
| Patient type | Paediatric: <8 years / <25 kg |
| Radiotransparency | Yes (electrode and cable), for artefact-free imaging |
| Cable configuration | Integrated internal cable (leads-in), 100 cm |
| Total surface per electrode | 75 cm² |
| Active surface per electrode | 40 cm² |
| Adhesive ring width | 0.7 cm |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | 1 mm thick medical foam |
| Connection type | Safety anti-shock connector compatible with Philips / Agilent-HP / Laerdal equipment |
| Functions | External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring |
| ECG monitoring | Up to 24 hours |
| Supported shocks | Up to 50 shocks at 100 J (paediatric series) |
| Regulatory classification | Medical device class IIb (EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993 |
| Primary packaging | 1 pair in heat-sealed polyethylene and aluminium bag with easy-open feature |
| Sales format | 5 pairs per box (paediatric series) |
| Shelf life | 30 months from the date of production (see expiry date on the packaging) |
| Storage | Dry place, between +5 °C and +35 °C |
| Composition | Latex-free and phthalate-free · Single-use |
3.1. Compatibility with defibrillators
| Family / Equipment model | Factory reference | Observations |
| CodeMaster 100 | M2475B | Direct connection / with hands-free cable M3507A |
| CodeMaster XE | M1724A | Direct connection |
| CodeMaster XL | M1723A / M1723B | Direct connection |
| CodeMaster XL+ | M1722A / M1722B | Direct connection |
| HeartStart 4000 | M5500B | Paediatric function and energy in manual setting |
| HeartStream / HeartStart XL | M4735A | Requires hands-free electrode cable M3508A |
| HeartStream / HeartStart XLT | M3500B | Requires hands-free electrode cable M3508A |
| HeartStart MRx | M3535A / M3536A | Requires cable M3508A; do not use in fully automatic mode |
| HeartStart FR AED / FR2 / FR2+ / FR3 | — | Direct compatibility (FR3: do not leave connected in standby; for <25 kg use the child/neonate key REF 989803150031) |
| Efficia DFM100 / HeartStart Intrepid | — | Direct connection |
Technical note: on the HeartStart 4000, XL/XLT and MRx models, the paediatric function and energy are adjusted manually; do not use with fully automatic defibrillators. Always verify the correct insertion of the connector before clinical use.
4. Equivalences and Cross-References
Reference F7750P corresponds to a radiotransparent paediatric multifunction electrode with internal cable for the defibrillator families Philips CodeMaster (HP/Agilent), HeartStart and Laerdal indicated above. After verifying manufacturer sources and regulatory databases (GUDID and official catalogues), the following cross-references with confirmed code are identified. In no case is there an official equivalence table validated by the manufacturer for this reference; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Philips Healthcare | Radiotransparent multifunction paediatric electrode pads | M3719A (989803125411) | Comparable by category (not interchangeable 1:1) | Original manufacturer reference for the same compatibility family (M1722A/B, M1723A/B, M1724A, M2475B, M3500B, M4735A, M5500B, M3535A/M3536A). Its data sheet is intended for infants <10 kg, with 60 cm cable and 50 cm² conductive surface; verify size, surface and connector before replacement. Code confirmed on the official Philips website and in GUDID (UDI 00884838002883). |
| Cardinal Health (Medi-Trace / Covidien) | Cadence Paediatric RTS (radiotransparent) for Philips | 22661P | Comparable by category (not interchangeable 1:1) | Radiotransparent paediatric pair with barrel connector compatible with the Philips/Agilent-HP family (CodeMaster XL+, HeartStream XLT, HeartStart XL, MRx and HeartStart 4000). Silver/silver chloride gradient technology for uniform current distribution. Code confirmed in the manufacturer’s catalogue and in GUDID (UDI 20884527022356). |
| Nissha Medical Technologies (HeartSync) | 97-DEFIB F/G PEDIATRIC-PHILIPS (D321) | 6600066H | Comparable by category (not interchangeable 1:1) | Radiolucent paediatric pair with internal cable (leads-in) for HeartStart XLT, XL+, XL, MRx and Intrepid; total surface 78.4 cm², tin and tin-copper conductive element with 1.5 m cable. Code confirmed in the manufacturer’s official catalogue; not suitable for use with an AED: verify compatibility with the exact model of the device. |
There is no equivalence table validated by Philips that authorises the replacement of the original references M3719A/M3504A with third-party pads: the connector, the analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the device connector, paediatric energy range, target population and package expiry. Consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
- Confirm the model and connector of the device: verify on the defibrillator plate the exact model (CodeMaster 100/XE/XL/XL+, HeartStart 4000, XL/XLT, MRx, Efficia DFM100, Intrepid, FR AED/FR2/FR3) and check the required therapy cable (M3508A / 989803197111 in models that require it) before storing the spare part.
- In HeartStart 4000, XL/XLT and MRx the paediatric function and energy are adjusted manually; do not use this electrode in fully automatic defibrillators. In FR3 devices, do not leave the electrodes connected in standby or off and, for patients <25 kg, use the child/neonate key REF 989803150031.
- Choose radiotransparent when imaging tests are anticipated: if the patient may require X-ray or CT during care, this version avoids artefacts without removing the electrode. If imaging is not required, consider the standard non-radiotransparent version F7950P, at lower cost; for patients over 25 kg use the radiotransparent adult version of the same family (F7750).
- Storage: keep in a dry place between +5 °C and +35 °C and respect the expiry date indicated on the package; the conductive gel may dry out and reduce its conductivity after the expiry date.
- Single-use: do not reuse; one pair per patient and clinical event. Manage stock rotation by expiry (approx. 30 months) and always keep a spare pair in centres with a paediatric population. Immediate availability from Cahnos with technical assistance for compatibility verification by model and connector.