Radiotransparent paediatric defibrillator electrode with internal cable (pair) – Replacement compatible with Philips: CodeMaster 100, XE, XL, XL+, HeartStart 4000, XL/XLT, MRx and Efficia DFM100 – Ref. F7750P

39,75 €

Pair of radiotransparent paediatric defibrillator electrodes with internal cable (ref. F7750P), replacement compatible with Philips defibrillators and monitors of the families CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), XL/XLT, MRx, Efficia DFM100 and HeartStart Intrepid. Indicated for children under 8 years or weighing less than 25 kg: the device recognises the paediatric electrode and adjusts the energy, avoiding inappropriate shocks. Its radiotransparent construction (electrode and cable) allows the pads to be kept in place during X-ray or CT without image artefacts. Low-impedance conductive adhesive gel, active surface of 40 cm² per electrode and ECG monitoring for up to 24 h. Latex-free and phthalate-free, single-use; individual heat-sealed packaging and 5 pairs per box.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7750P

Description

1. Commercial Introduction

Ensure safe cardiac care for the smallest patients with this pair of radiotransparent paediatric defibrillator electrodes with internal cable (reference F7750P), a high-reliability consumable compatible with the most widely used Philips defibrillator-monitor families in hospital and emergency settings: CodeMaster 100, XE, XL and XL+ (including factory references M2475B, M1724A, M1723A/B and M1722A/B), HeartStart 4000, XL/XLT, MRx, Efficia DFM100 and HeartStart Intrepid. Designed for emergency departments, paediatric ICU, ambulances, operating theatres and haemodynamics, it combines the advantages of the radiotransparent series — artefact-free imaging control — with the robustness of the integrated 100 cm internal cable, which maintains a stable connection throughout resuscitation. A cost-optimised solution, compliant with EU Regulation 2017/745 (class IIb) and latex- and phthalate-free.

2. Technical explanation of the equipment and procedure

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers therapy and monitors the response. This paediatric model allows transthoracic external defibrillation, synchronised cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring (up to 24 h), adapted to paediatric physiology (children under 8 years or weighing less than 25 kg). Its radiotransparent condition — in both the electrode and the cable — prevents artefacts in X-rays, CT scans and image-guided studies, so it can remain in place during examination without interrupting monitoring or therapy. The low-impedance conductive adhesive gel on medical foam with a metallic film ensures uniform current distribution and a reliable signal with a reduced pacing threshold. They are single-use: they must be replaced after each procedure or upon reaching the expiry date printed on the packaging, and placed according to the anatomical diagrams (sternal and apical positions) on the sachet.

3. Technical Specifications

Reference Cahnos (SKU) F7750P
Product type Pair of multifunction paediatric defibrillator electrodes, radiotransparent, with internal cable
Patient type Paediatric: <8 years / <25 kg
Radiotransparency Yes (electrode and cable), for artefact-free imaging
Cable configuration Integrated internal cable (leads-in), 100 cm
Total surface per electrode 75 cm²
Active surface per electrode 40 cm²
Adhesive ring width 0.7 cm
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material 1 mm thick medical foam
Connection type Safety anti-shock connector compatible with Philips / Agilent-HP / Laerdal equipment
Functions External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring
ECG monitoring Up to 24 hours
Supported shocks Up to 50 shocks at 100 J (paediatric series)
Regulatory classification Medical device class IIb (EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993
Primary packaging 1 pair in heat-sealed polyethylene and aluminium bag with easy-open feature
Sales format 5 pairs per box (paediatric series)
Shelf life 30 months from the date of production (see expiry date on the packaging)
Storage Dry place, between +5 °C and +35 °C
Composition Latex-free and phthalate-free · Single-use

3.1. Compatibility with defibrillators

Family / Equipment model Factory reference Observations
CodeMaster 100 M2475B Direct connection / with hands-free cable M3507A
CodeMaster XE M1724A Direct connection
CodeMaster XL M1723A / M1723B Direct connection
CodeMaster XL+ M1722A / M1722B Direct connection
HeartStart 4000 M5500B Paediatric function and energy in manual setting
HeartStream / HeartStart XL M4735A Requires hands-free electrode cable M3508A
HeartStream / HeartStart XLT M3500B Requires hands-free electrode cable M3508A
HeartStart MRx M3535A / M3536A Requires cable M3508A; do not use in fully automatic mode
HeartStart FR AED / FR2 / FR2+ / FR3 — Direct compatibility (FR3: do not leave connected in standby; for <25 kg use the child/neonate key REF 989803150031)
Efficia DFM100 / HeartStart Intrepid — Direct connection

Technical note: on the HeartStart 4000, XL/XLT and MRx models, the paediatric function and energy are adjusted manually; do not use with fully automatic defibrillators. Always verify the correct insertion of the connector before clinical use.

4. Equivalences and Cross-References

Reference F7750P corresponds to a radiotransparent paediatric multifunction electrode with internal cable for the defibrillator families Philips CodeMaster (HP/Agilent), HeartStart and Laerdal indicated above. After verifying manufacturer sources and regulatory databases (GUDID and official catalogues), the following cross-references with confirmed code are identified. In no case is there an official equivalence table validated by the manufacturer for this reference; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Philips Healthcare Radiotransparent multifunction paediatric electrode pads M3719A (989803125411) Comparable by category (not interchangeable 1:1) Original manufacturer reference for the same compatibility family (M1722A/B, M1723A/B, M1724A, M2475B, M3500B, M4735A, M5500B, M3535A/M3536A). Its data sheet is intended for infants <10 kg, with 60 cm cable and 50 cm² conductive surface; verify size, surface and connector before replacement. Code confirmed on the official Philips website and in GUDID (UDI 00884838002883).
Cardinal Health (Medi-Trace / Covidien) Cadence Paediatric RTS (radiotransparent) for Philips 22661P Comparable by category (not interchangeable 1:1) Radiotransparent paediatric pair with barrel connector compatible with the Philips/Agilent-HP family (CodeMaster XL+, HeartStream XLT, HeartStart XL, MRx and HeartStart 4000). Silver/silver chloride gradient technology for uniform current distribution. Code confirmed in the manufacturer’s catalogue and in GUDID (UDI 20884527022356).
Nissha Medical Technologies (HeartSync) 97-DEFIB F/G PEDIATRIC-PHILIPS (D321) 6600066H Comparable by category (not interchangeable 1:1) Radiolucent paediatric pair with internal cable (leads-in) for HeartStart XLT, XL+, XL, MRx and Intrepid; total surface 78.4 cm², tin and tin-copper conductive element with 1.5 m cable. Code confirmed in the manufacturer’s official catalogue; not suitable for use with an AED: verify compatibility with the exact model of the device.

There is no equivalence table validated by Philips that authorises the replacement of the original references M3719A/M3504A with third-party pads: the connector, the analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the device connector, paediatric energy range, target population and package expiry. Consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

  • Confirm the model and connector of the device: verify on the defibrillator plate the exact model (CodeMaster 100/XE/XL/XL+, HeartStart 4000, XL/XLT, MRx, Efficia DFM100, Intrepid, FR AED/FR2/FR3) and check the required therapy cable (M3508A / 989803197111 in models that require it) before storing the spare part.
  • In HeartStart 4000, XL/XLT and MRx the paediatric function and energy are adjusted manually; do not use this electrode in fully automatic defibrillators. In FR3 devices, do not leave the electrodes connected in standby or off and, for patients <25 kg, use the child/neonate key REF 989803150031.
  • Choose radiotransparent when imaging tests are anticipated: if the patient may require X-ray or CT during care, this version avoids artefacts without removing the electrode. If imaging is not required, consider the standard non-radiotransparent version F7950P, at lower cost; for patients over 25 kg use the radiotransparent adult version of the same family (F7750).
  • Storage: keep in a dry place between +5 °C and +35 °C and respect the expiry date indicated on the package; the conductive gel may dry out and reduce its conductivity after the expiry date.
  • Single-use: do not reuse; one pair per patient and clinical event. Manage stock rotation by expiry (approx. 30 months) and always keep a spare pair in centres with a paediatric population. Immediate availability from Cahnos with technical assistance for compatibility verification by model and connector.

Additional information

Product type

Pair of multifunction paediatric defibrillator electrodes, radiotransparent, with internal cable

Patient type

Paediatric:

Compatibility

CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), HeartStream XL (M4735A), XLT (M3500B), HeartStart MRx (M3535A/M3536A), HeartStart FR AED/FR2/FR2+/FR3, Efficia DFM100, HeartStart Intrepid

Required accessories

With HeartStart 4000, XL/XLT and MRx: hands-free electrode cable M3508A / 989803197111; FR3

Radiolucent

Yes (electrode and cable)

Cable type

Integrated internal cable, 100 cm

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Supported shocks

Up to 50 shocks at 100 J (paediatric series)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm thick medical foam

Connection type

Safety anti-shock connector compatible with Philips / Agilent-HP / Laerdal

ECG monitoring

Up to 24 hours

Presentation

1 pair in heat-sealed polyethylene and aluminium bag

Sales format

5 pairs per box (paediatric series)

Regulatory classification

Medical device class IIb (EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Use

Single-use, disposable; latex-free and phthalate-free

Latex-free and phthalate-free

Yes

Shelf life

30 months from the date of production

Storage

Dry place, between +5 °C and +35 °C

Radiotransparency

Yes (electrode and cable)

Cable configuration

Integrated internal cable (leads-in), 100 cm

Adhesive ring width

0.7 cm

Functions

External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring

Reference standards

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993