Pair of adult radiolucent defibrillator electrodes with external cable (pre-connected) – Compatible replacement for Philips HeartStream ForeRunner AED, HeartStart FR AED/FR2/FR2+ and CodeMaster 100/XE/XL/XL+ families, HeartStart 4000/XL/XLT/MRx – Ref. F7750W

34,98 €

Pair of defibrillator electrodes adult radiolucent with pre-connected external cable (Ref. F7750W), replacement consumable compatible with Philips defibrillators HeartStream ForeRunner AED, HeartStart FR AED/FR2/FR2+, CodeMaster 100/XE/XL/XL+ families and HeartStart 4000, XL/XLT and MRx equipment. Their radiolucent construction (electrode and cable) allows the pads to remain in place during X-ray or CT without image artefacts, and the external cable leaves the device ready in seconds in an emergency. Low-impedance conductive adhesive gel, 136 cm² total surface and 94 cm² active area per electrode, up to 50 shocks at 360 J and ECG monitoring for up to 24 h. Single-use, latex-free and phthalate-free, class IIb medical device; immediate dispatch and technical support to verify compatibility by model and connector.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7750W

Description

1. Commercial Introduction

Keep your Philips defibrillator always operational with this pair of adult radiotransparent defibrillator electrodes with external cable (reference Cahnos F7750W), a high-reliability consumable compatible with the most widespread Philips AED and defibrillator-monitor families: HeartStream ForeRunner AED (E, S, EM), HeartStart FR AED, FR2 and FR2+, CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), XL/XLT and MRx. Designed for emergency services, ICUs, ambulances, operating theatres, haemodynamics and cardioprotected spaces, it combines the radiotransparent series —image control without artefacts— with the external cable configuration: the connector remains accessible outside the packaging, so the pair can be left pre-connected and ready for emergencies without opening the pouch. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock, enables synchronised cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency ECG monitoring. This adult model (patients over 8 years old or weighing more than 25 kg) is constructed with low-impedance conductive adhesive gel, which ensures homogeneous contact with the skin and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest.

Its radiotransparent condition —in the electrode and the cable— prevents artefacts in radiography, radioscopy and tomography, so the pads can remain in place during imaging without interrupting monitoring or therapy. The external cable variant leaves the connector and the approximately 120 cm cable outside the bag: the pair remains pre-connected and ready, reducing preparation time at the critical moment. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging, being placed in the anterolateral position (sternum-apex) according to the anatomical diagrams on the pouch.

3. Technical specifications and compatibility

3.1 Technical specifications

Main features of the series of adult radiotransparent electrodes with external cable to which this reference belongs:

Parameter Specification
Reference Cahnos (SKU) F7750W
Product type Pair of adult multifunction defibrillator electrodes, radiotransparent, with external cable (pre-connected)
Patient type Adult (older than 8 years / more than 25 kg)
Radiotransparency Yes (electrode and cable), suitable for imaging procedures
Cable configuration External cable: connector and cable approx. 120 cm outside the bag, immediate connection
Total surface per electrode 136 cm² (adult series)
Active surface per electrode 94 cm² (adult series)
Adhesive ring width 0.7 cm
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Connection type Safety anti-shock connector compatible with Philips equipment
Functions External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring
ECG monitoring Up to 24 hours
Supported shocks Up to 50 shocks at 360 J
Composition Latex-free and phthalate-free · Single-use
Presentation 1 pair in heat-sealed polyethylene and aluminium bag
Sales format 10 pairs per box (adult series)
Shelf life Approx. 30 months from production date (see expiry on the packaging)
Storage Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C
Regulatory classification Medical device class IIb (EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Note: the values for active surface (94 cm²), total area (136 cm²), discharges (50 to 360 J) and adhesive ring (0.7 cm) correspond to the series of adult radiotransparent electrodes with external cable of this product family; confirm them with the technical data sheet of the supplied batch and the device manual before use in tendering.

3.2 Compatibility with defibrillators

Family / Equipment model Factory reference Observations
HeartStream ForeRunner AED (E, S, EM) — Direct connection of the pads
HeartStart FR AED / FR2 / FR2+ FR2: M3840A, M3841A · FR2+: M3860A, M3861A Direct connection; on FR3 do not leave connected in standby or off
CodeMaster 100 M2475B Direct connection / with hands-free cable M3507A
CodeMaster XE M1724A Direct connection
CodeMaster XL / XL+ M1723A/B · M1722A/B Direct connection
HeartStart 4000 M5500B Energy in manual adjustment
HeartStream / HeartStart XL M4735A Requires hands-free electrode cable M3508A
HeartStream / HeartStart XLT M3500B Requires hands-free electrode cable M3508A
HeartStart MRx M3535A / M3536A Requires cable M3508A; do not use in fully automatic mode
HeartStart FR AED (versions) 940010XX, 940020XX, 940030XX Direct connection

Technical note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your device before clinical use.

4. Equivalences and Cross-References

Reference F7750W is a consumable compatible with the cited Philips defibrillators, not an original spare part certified by the device manufacturer: the connector, the analysis algorithm and energy management are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID), the following cross-references with confirmed codes in public sources are identified. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Philips Healthcare Adult Multifunction Pads, IEC barrel connector (original equipment) M3502A (alternative code 989803106931) Comparable by category (not interchangeable 1:1) Factory original for the CodeMaster 100 (M2475B), XE (M1724A), XL/XL+ (M1723A/B, M1722A/B), HeartStart 4000 (M5500B), XL (M4735A), XLT (M3500B) and MRx (M3535A/M3536A) families. Code confirmed in authorised technical distribution. It is not radiotransparent (standard version); verify connector, surface and cable before replacement.
Philips Healthcare HeartStart Adult Defibrillator Pads (AED FR2/FR2+ / ForeRunner) 989803158211 (1 pair) / 989803158221 (5 pairs) Comparable by category (not interchangeable 1:1) Original for the AEDs of the HeartStart FR2/FR2+ and ForeRunner families, indicated for patients ≥8 years or ≥25 kg; code confirmed on the official Philips website and in GUDID (DI 00884838023710 / 00884838126299). Not radiotransparent; connector and algorithm proprietary to the same AED platform.
Cardinal Health (Medi-Trace™ Cadence) Adult Multi-Function Defibrillation Electrodes, Radiotransparent, Philips barrel connector 22661R (preconnected: 22661PC) Comparable by category (not interchangeable 1:1) Adult radiotransparent pair with barrel connector compatible with the Philips/Agilent-HP family (HeartStream/HeartStart XL, XL+, MRx and CodeMaster); silver/silver chloride gradient technology and 10 pairs per box. Code confirmed in GUDID (DI 20884527022370) and manufacturer catalogue. Verify connector and surfaces before replacement.
Nissha Medical Technologies (HeartSync) 97-DEFIB F/G C100AC-PHILIPS (D311) 6600015H (ref. C100AC-PHILIPS) Comparable by category (not interchangeable 1:1) Adult radiotransparent pair with internal cable (leads-in) and connector comparable to the original Philips; total surface of 371 cm², carbon conductive element, 1.5 m cable and 36 months of service life. Code confirmed in the manufacturer’s official catalogue. Not suitable for all models: verify connector and compatibility with the exact device.

There is no equivalence table validated by the manufacturer that authorises the replacement of original Philips electrodes with third-party pads: the connector, the analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the device connector, the energy range, the target population and the packaging expiry. Consult the technical department of Cahnos before use in tendering.

5. Selection tips and variants of interest

Confirm the model and connector of the device: verify on the defibrillator plate the exact model (ForeRunner AED, FR AED/FR2/FR2+, CodeMaster 100/XE/XL/XL+, HeartStart 4000, XL/XLT or MRx) and check the required therapy cable (M3507A / M3508A on models that require it) before storing the spare part.

Operating mode: in HeartStart 4000, XL/XLT and MRx the energy is adjusted manually; do not use this electrode in fully automatic defibrillators. On FR3 devices do not leave the electrodes connected in standby or powered off.

Choose radiolucent when imaging tests are anticipated: if the patient may require X-ray, fluoroscopy or CT during care, this version avoids artefacts without removing the electrode. If imaging is not required, the standard non-radiolucent version of the same platform (F7950W) may be considered, at a lower cost.

Variants of the same family at Cahnos: radiolucent version with internal cable (F7750) if you prefer a direct connection without a loose cable; paediatric radiolucent version (F7750P) for patients under 8 years or 25 kg. For other platforms in the radiolucent category with external cable, F7751W (ZOLL Medical), F7752W (Physio-Control / Bexen / Mindray), F7753W (Agilent HP / Laerdal), F7755W (Nihon Kohden / Welch Allyn / Dräger) and F7760W (Metrax Primedic) are available, not interchangeable with each other due to proprietary connector.

Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO).

Institutional orders: for consortia, tenders or fleet maintenance, contact the technical-commercial department at Cahnos indicating the exact model and serial number of your equipment; we will confirm compatibility before finalising the order.

Additional information

Compatibility

Philips (proprietary barrel connector)

Compatible models

HeartStream ForeRunner AED (E, S, EM); HeartStart FR AED (940010XX, 940020XX, 940030XX), FR2 (M3840A, M3841A), FR2+ (M3860A, M3861A); CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B); HeartStart 4000 (M5500B), XL (M4735A), XLT (M3500B), MRx (M3535A/M3536A)

Required cables

M3507A (barrel) or M3508A (plug) depending on model; verify connector fit

Product type

Pair of adult multifunction defibrillator electrodes, radiotransparent, with external cable (pre-connected)

Patient type

Adult (older than 8 years / more than 25 kg)

Cable configuration

External cable: connector and cable approx. 120 cm outside the bag, immediate connection

Radiotransparency

Yes (electrode and cable), suitable for artefact-free imaging

Total surface per electrode

136 cm²

Active surface per electrode

94 cm²

Adhesive ring width

0.7 cm

Supported shocks

Up to 50 shocks at 360 J

Functions

External defibrillation, synchronized cardioversion, transcutaneous pacing (pacemaker) and ECG monitoring

ECG monitoring

Up to 24 hours

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

Medical foam (FOAM) 1 mm thick

Connection type

Safety anti-shock connector compatible with Philips equipment

Use

Single-use, disposable, non-sterile; latex-free and phthalate-free

Presentation

1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series)

Shelf life

Approx. 30 months from production date (expiry on packaging)

Regulatory classification

Medical device class IIb (EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Storage

Dry place between +5 °C and +35 °C; operating range 0 °C to +50 °C