We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Neonatal radiotransparent foam ECG electrode Ø 22 mm, pre-wired, 60 cm lead and 1.55 mm connection (DIN 1.5 mm socket – DIN 42802) – RT 22 LWS – Neonatal ICU monitoring – Box of 300 units (SKU 15080)

3,02 €

Neonatal radiotransparent foam electrode Ø 22 mm (RT 22 LWS, SKU 15080) for continuous ECG monitoring of newborns and premature infants, with a pre-wired 60 cm lead and 1.55 mm connection (DIN 1.5 mm safety socket, DIN 42802) compatible with European-standard monitor lead wires. Its radiotransparent medical foam reduces the adhesive surface area on the neonate’s delicate skin and allows monitoring to be maintained during X-rays and imaging tests without artefacts or interruptions. Stable trace, gentle adhesion, single-use disposable and latex-free. Presentation: bag of 3 units; minimum box of 300 units for hospital supply.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
15080

Description

1. Commercial Introduction

The radiotransparent foam electrode RT 22 LWS (SKU 15080) is a disposable ECG monitoring consumable designed specifically for newborns and premature infants. With a diameter of Ø 22 mm, a pre-cabled 60 cm lead and a 1.55 mm connection (1.5 mm DIN safety connector), it provides reliable, continuous electrocardiographic recording with minimal impact on the neonate’s delicate skin. Its radiotransparent medical foam construction allows the electrodes to remain in place during X-rays and other imaging examinations without interference, a critical feature in neonatal intensive care units, neonatology departments and neonatal transport. It is supplied in a bag of 3 units, with a minimum box of 300 units, suited to the continuous consumption of hospitals and procurement centres.

2. Technical Explanation

The electrode acts as an interface between the neonate’s skin and the bedside monitor: the foam backing (medical foam) ensures a gentle yet firm fixation on the newborn’s immature skin, while the conductive sensor element on low-impedance solid gel guarantees stable signal transmission for a clean, continuous ECG trace. The integrated 60 cm lead terminates in a 1.55 mm connection, known commercially as the 1.5 mm DIN safety connector (DIN 42802), compatible with most ECG monitor lead wires with European standard. Its radiotransparent nature allows monitoring to be maintained during X-rays, fluoroscopy and other imaging examinations without generating artefacts or interruptions, an essential aspect when the neonatal patient requires continuous cardiac monitoring during the examination. It is a single-use, latex-free product: it must be discarded after each patient and the expiry date of the packaging must be respected so as not to compromise the conductivity of the adhesive or the gel.

3. Technical Specifications

Parameter Specification
Reference / SKU 15080
Model / family RT 22 LWS
Type Radiolucent foam electrode for neonatal monitoring
Material Foam (medical foam) and radiolucent material
Diameter Ø 22 mm
Cable 60 cm, pre-wired
Connection 1.55 mm (DIN safety connector type 1.5 mm – DIN 42802)
Sensor / gel Conductive sensor on low-impedance solid gel
Radiotransparency Yes, suitable for radiography and imaging examinations (plain film / X-ray)
Application Neonatal ECG monitoring, neonatal ICUs, incubators, neonatal transport
Use Single-use (disposable), latex-free
Presentation Bag of 3 units
Minimum sales unit Box of 300 units
Regulatory classification Medical device with CE marking

Note: the connection values (1.55 mm) and presentation (3 units/bag, 300 units/box) are copied literally from the distributor’s technical documentation; confirm them with the technical data sheet of the supplied lot. Radiotransparency refers to use with plain film (X-ray); check the equipment manual for MRI compatibility before use in MRI.

4. Equivalences and Cross-References

This reference belongs to the category of pre-cabled, radiotransparent neonatal monitoring electrodes with 1.5 mm DIN connector. After verifying official manufacturer catalogues, authorised distribution and regulatory databases (GUDID/FDA), the following cross-references with codes confirmed in public sources have been identified. Any comparison between brands should be understood as comparable by category (not 1:1 interchangeable): check one by one the backing material, diameter, connector type and monitor lead wire before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
3M / Solventum (Red Dot™) Series 2200, pre-wired radiolucent neonatal electrode, soft cloth 22×22 mm 2282 / 2282L (GUDID 50707387468557 / 50707387569278) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID, the official Solventum website and authorised distribution. Soft cloth backing (soft cloth) versus foam; surface 22×22 mm, pre-cabled 60 cm radiolucent lead with 1.5 mm DIN connector. Verify connector and monitor lead wire.
Cardinal Health (Kendall™) KittyCat™ Cloth Pre-Wired, neonatal radiolucent 1051NPSM / 31424743 (GUDID 50192253017357) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and the Cardinal Health catalogue. 2.5 cm cloth, ~60 cm cable (24 in.), 0.060 in. safety connector (≈1.5 mm DIN), radiolucent, in strips of 3 units. It is not foam; verify connector.
Halbach Medical Clinical ECG Electrode P22DR (neonatal) EC849923 Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: Ø 22 mm, 60 cm cable, 1.5 mm DIN connector, hydrogel, radiolucent and repositionable. The manufacturer declares it comparable to Red Dot 2282/2269 and Kendall KittyCat 1051NPSM.
FIAB Group Pre-cabled radiotransparent neonatal series F9057PRRM / F9057NQ/RM/50 (also F9057NRM and F9057NQ/RM/AAMI) Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue and authorised distribution: oval formats 20×15 mm, 23×30 mm or square 22×22 mm, 50-60 cm cable, 1.5 mm DIN connector, SSC sensor, non-woven backing and radiotransparent. Different geometry and non-woven backing versus foam.

There is no equivalence table validated by the manufacturer that authorises the replacement of the original electrodes with third-party patches: the connector, the lead wire and the patch size are specific to each monitoring platform. Any replacement must be validated against the technical data sheet and instructions for use of the monitor and the electrode; consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

Check the connector type of your monitor: this reference uses a 1.55 mm connection (1.5 mm DIN connector). If your lead wire uses a 4 mm connector, request the RT 22 LWF variants from the same family with 4 mm connection (SKU 15079 for Ø 22 mm or SKU 15081 for Ø 30 mm). Both formats are not interchangeable with each other without an adapter.

Choose the diameter according to weight and chest surface area: this Ø 22 mm electrode is the smallest format in the family, recommended for very low birth weight neonates and extremely premature infants. If the patient has a larger chest surface area, the RT 22 LWS version with Ø 30 mm and the same 1.55 mm connection (SKU 15082) is available.

Radiotransparency: if the patient may require X-ray or imaging during monitoring, this version avoids artefacts without removing the electrode; radiotransparency is intended for plain X-ray imaging. Check the equipment manual for MRI compatibility.

Single-use and storage: disposable, single-use per patient; store in a dry place and observe the expiry date on the packaging so as not to compromise the conductivity of the adhesive or the quality of the gel.

Institutional orders: the minimum box of 300 units is intended for the supply of neonatology and ICU departments; for tenders and bids, contact the technical-commercial department at Cahnos to confirm compatibility with your monitor fleet before finalising the order.

Additional information

Product type

Radiolucent foam electrode for neonatal monitoring

Model / family

RT 22 LWS

Material

Foam (medical foam) and radiolucent material

Diameter

Ø 22 mm

Cable

60 cm pre-cabled

Connection

1.55 mm (DIN safety connector type 1.5 mm – DIN 42802)

Radiotransparency

Yes, suitable for radiography and imaging examinations (X-rays)

Application

Neonatal ECG monitoring, neonatal ICUs, incubators, neonatal transport

Use

Single-use (disposable), latex-free

Presentation

Bag of 3 units

Connector limit

Compatible with ECG monitor lead wires with 1.5 mm DIN connector

Cable length

60 cm, pre-wired

Connection type

1.55 mm (DIN safety connector type 1.5 mm – DIN 42802)

Gel sensor

Conductive sensor on low-impedance solid gel

Minimum sales unit

Box of 300 units

Regulatory classification

Medical device with CE marking

Reviews

There are no reviews yet.

Be the first to review “Neonatal radiotransparent foam ECG electrode Ø 22 mm, pre-wired, 60 cm lead and 1.55 mm connection (DIN 1.5 mm socket – DIN 42802) – RT 22 LWS – Neonatal ICU monitoring – Box of 300 units (SKU 15080)”