Paediatric radiolucent defibrillator electrode with internal cable (pair) – Compatible replacement for Philips, Agilent Hewlett-Packard and Laerdal Medical: CodeMaster 100, XE, XL, XL+ and HeartStart 4000 – Ref. F7753P

39,75 €

Pair of paediatric multifunction electrodes radiolucent with internal 100 cm cable (ref. F7753P), compatible replacement for defibrillator monitors Philips, Agilent Hewlett-Packard and Laerdal Medical: CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), XL/XLT and MRx. Indicated for children under 8 years of age or weighing less than 25 kg: the device recognises the paediatric electrode and automatically adjusts the energy. Low-impedance conductive adhesive gel, active surface area of 40 cm² per electrode and up to 50 shocks at 100 J. Its radiolucent design prevents artefacts in radiography and CT without removing the electrode. Latex-free and phthalate-free, single-use; individually heat-sealed packaging and 5 pairs per box. Immediate dispatch from Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7753P

Description

1. Commercial Introduction

The radiolucent paediatric defibrillator electrode with internal cable (ref. F7753P) is the ideal replacement and replenishment solution for emergency departments, critical care units, ambulances and AED-equipped areas that treat paediatric patients with equipment from the Philips, Agilent Hewlett-Packard and Laerdal Medical families, including the CodeMaster 100, XE, XL and XL+ series and the HeartStart 4000. With a single reference it covers the most widespread hospital fleets of defibrillator-monitors from these brands, simplifying consumables stock. Price per pair of electrodes; individually heat-sealed pack with immediate dispatch from Cahnos and specialised technical support.

2. Technical Explanation

The disposable multifunction electrodes allow, with the same pair of pads, transthoracic external defibrillation, synchronised cardioversion, temporary transcutaneous cardiac pacing and ECG monitoring. In this paediatric model, the low-impedance conductive adhesive gel and the internal metal foil ensure efficient energy transmission with a reduced pacing threshold, while the 1 mm thick medical foam backing adapts to the infant patient’s chest.

When connected to a compatible defibrillator, the device recognises the paediatric electrode and adjusts the energy to paediatric mode, avoiding inappropriate shocks in children under 8 years or weighing less than 25 kg. The integrated cable (internal cable configuration, 100 cm) provides a stable connection and clean placement during resuscitation. Furthermore, the radiolucency of the electrode and cable prevents artefacts in X-rays, CT scans and imaging studies, a key factor in paediatric patients who require examination during care.

3. Technical Specifications

Parameter Specification
Patient type Paediatric: <8 years / <25 kg
Radiotransparency Yes (electrode and cable)
Cable configuration Integrated internal cable (leads-in), 100 cm
Total surface per electrode 75 cm²
Active surface per electrode 40 cm²
Adhesive ring width 0.7 cm
Supported shocks Up to 50 shocks at 100 J
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material 1 mm thick medical foam
Connection type Safety anti-shock connector compatible with Philips / Agilent HP / Laerdal equipment
ECG monitoring Up to 24 hours
Regulatory classification Medical device class IIb (EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993
Primary packaging 1 pair in heat-sealed polyethylene and aluminium bag with easy-open feature
Sales format 5 pairs per box (paediatric series)
Shelf life 30 months from the date of production (see expiry date on the packaging)
Storage Dry place, between +5 °C and +35 °C; resistant to -30 °C and +65 °C for short periods (max. 7 days)
Composition Latex-free and phthalate-free · Single-use

3.1 Compatibility with defibrillators

Equipment model Factory reference Observations
CodeMaster 100 M2475B Direct connection
CodeMaster XE M1724A Direct connection
CodeMaster XL M1723A / M1723B Direct connection
CodeMaster XL+ M1722A / M1722B Direct connection
HeartStart 4000 M5500B Paediatric function and energy in manual setting
HeartStream / HeartStart XL M4735A Paediatric function and energy in manual setting
HeartStream / HeartStart XLT M3500B Paediatric function and energy in manual setting
HeartStart MRx M3535A / M3536A With hands-free electrode cable M3508A

Note: with HeartStart 4000, XL/XLT and MRx do not use in fully automatic defibrillators; the paediatric function and energy are adjusted manually. Always verify correct connector insertion before clinical use.

4. Equivalences and Cross-References

The reference F7753P corresponds to a radiolucent paediatric multifunction electrode with internal cable for the Philips CodeMaster (HP/Agilent) and Laerdal Medical defibrillator families indicated above. After verifying manufacturer sources and regulatory databases (GUDID and official catalogues), the following cross-references with confirmed code are identified. In no case does an official equivalence table validated by the manufacturer exist for this reference; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Philips Healthcare Paediatric multifunction radiotransparent electrodes (plug-in connection) M3719A / 989803125411 Comparable by category (not interchangeable 1:1) Original manufacturer reference of the equipment for the same compatibility family (M1722A/B, M1723A/B, M1724A, M2475B, M3500B, M4735A, M5500B, M3535A/M3536A). Code confirmed in GUDID and official Philips website. Its datasheet indicates it for infants <10 kg, with 60 cm cable and conductive surface area of 50 cm²; verify size, surface and connector before replacement.
Cardinal Health (Covidien) Medi-Trace Cadence paediatric RTS (radiotransparent) 22661P Comparable by category (not interchangeable 1:1) Radiolucent paediatric pair (barrel connector compatible with Philips HP) for the CodeMaster XL+ (M1722A/B, M1723A/B), HeartStream XLT (M3500B), HeartStart XL (M4735A), MRx and HeartStart 4000 (M5500B) equipment family. Code confirmed in the manufacturer’s catalogue and several distribution sources; verify connector, cable and surfaces before use.
Nissha Medical Technologies (HeartSync) Paediatric defibrillation pad for Philips 6600066H (PEDIATRIC-PHILIPS, D321) Comparable by category (not interchangeable 1:1) Radiolucent paediatric pair with internal cable (leads-in) for HeartStart XLT, XL+, XL, MRx and Intrepid; total surface area 78.4 cm² and conductive element of tin and tin-copper with 1.5 m cable. Code confirmed in the manufacturer’s own catalogue; not suitable for use with AED: verify compatibility with the exact equipment model.

There is no official equivalence table validated by the manufacturer for this reference; consult with the technical department before use in tenders.

5. Selection tips and variants of interest

  • Select according to the patient: this paediatric reference is for children under 8 years or weighing less than 25 kg. For patients over 25 kg use the radiolucent adult version of the same family (F7753).
  • Choose radiolucent when imaging tests are anticipated: if the patient may require X-ray or CT scan during care, this version avoids artefacts without removing the electrode. If imaging is not required, the standard version with internal cable (F7953P), at lower cost, or the standard version with external cable (F7953PW) may be considered.
  • Verify the equipment configuration: in the HeartStart 4000, XL/XLT and MRx series models, the paediatric function and energy are adjusted manually; always check connector and cable compatibility before storing the spare.
  • Storage: keep in a dry place between +5 °C and +35 °C and respect the expiry date indicated on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date.
  • Single use: do not reuse; one pair per patient and clinical event. Immediate availability from Cahnos with technical assistance for compatibility verification by model and connector.

Additional information

Patient type

Paediatric (

Radiotransparency

Yes (electrode and cable)

Cable configuration

Integrated internal cable (leads-in), 100 cm

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Supported shocks

Up to 50 shocks at 100 J

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector compatible with Philips / Agilent HP / Laerdal

ECG monitoring

Up to 24 hours

Compatibility

CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), HeartStream/HeartStart XL (M4735A), XLT (M3500B), HeartStart MRx (M3535A/M3536A)

Regulatory classification

Medical device class IIb (EU Regulation 2017/745)

Reference standards

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993

Presentation

Pair of electrodes in individual heat-sealed packaging

Shelf life

30 months from production

Storage

Dry place, +5 °C to +35 °C; withstands -30 °C and +65 °C max. 7 days

Composition

Latex-free and phthalate-free · Single-use

Reference

F7753P

Radiolucent

Yes (electrode and cable)

Cable type

Integrated internal cable (leads-in), 100 cm

Adhesive ring width

0.7 cm

Sales format

5 pairs per box (paediatric series)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993

Use

Single-use, disposable

Latex-free and phthalate-free

Yes