We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Radiotransparent paediatric defibrillator electrode with internal cable — Compatible replacement for ZOLL PD 1200 to PD 2000, E Series, M Series and R Series — Ref. F7751P

39,75 €

Pair of radiotransparent paediatric defibrillator electrodes with internal cable (Ref. F7751P), a high-reliability replacement compatible with the ZOLL PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series and R Series defibrillators and monitors. Indicated for children under 8 years of age or under 25 kg, it is multifunctional: defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring. Its radiotransparent construction (electrode and cable) allows imaging without artefacts, and the integrated 100 cm internal cable ensures a stable connection throughout the procedure. Low-impedance conductive adhesive gel, active area of 40 cm² per electrode, single-use, without latex or phthalates. Sold in pairs; 5 pairs per box.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7751P

Description

1. Commercial Introduction

Ensure safe and effective cardiac care for the smallest patients with this pair of radiotransparent paediatric defibrillator electrodes with internal cable (reference F7751P), a high-reliability consumable compatible with ZOLL defibrillators and monitors from the PD, E, M and R series. Designed for emergency services, paediatric ICU, medical transport and AED settings, it combines the advantages of the radiotransparent series — artefact-free imaging — with the robustness of the integrated internal cable, which maintains a stable connection throughout resuscitation. A cost-optimised solution, compliant with European medical device standards (Class IIb) and latex- and phthalate-free.

2. Technical explanation of the equipment and procedure

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them, the device analyses the rhythm, delivers therapy and monitors the response. This paediatric model allows transthoracic external defibrillation, synchronized cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring (up to 24 h), adapted to paediatric physiology (children under 8 years or weighing less than 25 kg). Its radiotransparent condition — electrode and cable — avoids artefacts in imaging studies, so it can remain in place during X-rays or CT scans without interfering with diagnostics. The low-impedance conductive adhesive gel on medical foam with a metallic film ensures uniform current distribution and a reliable signal. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging, placed according to the anatomical diagrams (sternal and apical position) on the sachet.

3. Technical Specifications

Radiotransparent paediatric multifunction electrode from the EuroDefiPads paediatric series, in its integrated internal cable variant of 100 cm.

Field Specification
Reference Cahnos (SKU) F7751P
Product type Pair of multifunction paediatric defibrillator electrodes, radiotransparent, with internal cable
Indicated population Children under 8 years or weighing less than 25 kg
Cable 100 cm, internal (integrated)
Radiotransparency Yes (electrode and cable), for artefact-free imaging
Functions Defibrillation, synchronised cardioversion, non-invasive external pacing and ECG monitoring (max. 24 h)
Supported shocks From 50 to 100 J (paediatric series)
Total / active area (per electrode) 75 cm² total / 40 cm² active
Conductive gel Low-impedance conductive adhesive gel
Backing material Medical foam (1 mm) with conductive metal foil
Connection type Specific connector for ZOLL equipment (verify correct fit in the device socket)
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series)
Use Single-use, disposable; latex-free and phthalate-free
Shelf life Approx. 30 months from date of manufacture (check printed expiry date)
Conditions of use and storage Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C
Classification Class IIb medical device (EU Regulation 2017/745)
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

Compatibility (equipment models)

Equipment manufacturer Compatible models
ZOLL Medical PD 1200, PD 1400, PD 1600, PD 1700, PD 2000
ZOLL Medical E Series, M Series, R Series

Technical note: according to the manufacturer’s documentation for the original ZOLL electrodes, with M Series, E Series and R Series equipment the manual mode must be used: energy levels are not adjusted automatically and the device does not recognise them as intelligent paediatric electrodes. Always verify the correct insertion of the connector before clinical use.

4. Equivalences and Cross-References

This electrode (SKU F7751P) is a consumable compatible with the cited ZOLL equipment, not an original factory spare part. The correspondence with the equipment manufacturers’ references is as follows; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
ZOLL Medical Pedi·Padz II — multifunction paediatric electrodes (original equipment) 8900-0810-01 Comparable by category (not interchangeable 1:1) Factory original for ZOLL equipment (AED Plus and AED Pro with intelligent paediatric capability; M/E/R Series in manual mode). Hydrogel with tin conductive element, pre-connected, paediatric range 0–8 years / less than 25 kg with energy levels of 50/70/85 J. Code confirmed in the official ZOLL store, authorised distributors and GUDID (UDI 00847946001438).
Stryker / Physio-Control Infant/Child Reduced Energy Defibrillation Electrodes (for LIFEPAK with pink connector) 11101-000016 Comparable by category (not interchangeable 1:1) Paediatric electrode with energy reduction (200 J → ≈50 J) for the LIFEPAK 500, 1000, EXPRESS and CR Plus AEDs; proprietary QUIK-COMBO connector and algorithm, not suitable for ZOLL equipment. Code confirmed in the official Stryker store and in GUDID (UDI 00721902629013).

There is no equivalence table validated by ZOLL Medical that authorises the replacement of the original Pedi·Padz II electrodes with third-party pads: the connector, the analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator. Consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

Confirm the model and connector of the device: this pair corresponds to the ZOLL defibrillators and monitors PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series and R Series. Verify the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention.

Choose the variant according to your workflow: the internal cable of this model provides a clean and robust connection during resuscitation; if you prefer to leave the device pre-connected and ready in seconds, you have reference F7751PW (same paediatric radiotransparent series with external cable). For standard use without radiotransparency requirement, consider F7951P (standard paediatric with internal cable) or F7951PW (standard paediatric with external cable). The adult version of this same radiotransparent series is F7751 (internal cable) and F7751W (external cable).

Maintenance and provisioning: manage stock rotation by expiry date (approx. 30 months from manufacture) and always keep a spare pair with the device in centres with paediatric populations. For volume orders or tenders, contact the technical department at Cahnos stating the exact model and serial number of the defibrillator.

Additional information

Reference

F7751P

Product type

Pair of paediatric multifunction radiotransparent defibrillator electrodes with internal cable

Compatibility

PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series and R Series

Population

Paediatric: under 8 years or less than 25 kg

Cable

Internal (integrated), 100 cm

Radiolucent

Yes (electrode and cable)

Total area

75 cm² per electrode

Active area

40 cm² per electrode

Supported shocks

50 to 100 J

Functions

Defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring (max. 24 h)

Conductive gel

Low-impedance conductive adhesive gel

Material

Medical foam (1 mm) with conductive metal foil

Connection type

Specific connector for ZOLL equipment (check fit in the device socket)

Presentation

1 pair (2 electrodes) in heat-sealed bag; 5 pairs per box

Use

Single-use, disposable; latex-free and phthalate-free

Shelf life

Approx. 30 months from date of manufacture

Storage

Dry place between +5 °C and +35 °C; operating range 0 °C to +50 °C

Classification

Class IIb medical device (EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

Reviews

There are no reviews yet.

Be the first to review “Radiotransparent paediatric defibrillator electrode with internal cable — Compatible replacement for ZOLL PD 1200 to PD 2000, E Series, M Series and R Series — Ref. F7751P”

Your email address will not be published. Required fields are marked *