Description
1. Commercial Introduction
Keep your Schiller defibrillator always operational with this pair of adult radiotransparent defibrillator electrodes with internal cable (Ref. F7756), a replacement consumable designed for the FRED Easy, FRED Easy 2G, FRED Easy Life and Defigard DG 4000, DG 5000 and DG 6002 equipment. It is the ideal replacement solution for emergency services, intensive care units, ambulances, operating theatres, haemodynamics rooms and any cardio-protected space equipped with Schiller. Its integrated internal cable configuration protects the connector until the moment of use and its radiotransparent nature keeps the patient’s chest visible for imaging control without removing the patches. Available with immediate dispatch from Cahnos and specialised technical support to verify compatibility by model and connector.
2. Technical Explanation
These patches are disposable single-use multifunction electrodes: through them the defibrillator analyses the cardiac rhythm, delivers the transthoracic shock and monitors the electrocardiographic response during cardiopulmonary resuscitation. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal sheet distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the adult chest.
Being radiotransparent, the electrode and its cable do not generate artefacts in radioscopy, tomography or intraoperative control, allowing assessment of the rib cage, an implanted pacemaker or vascular access without interrupting monitoring. The recommended placement is anterolateral (sternal and apical position), without the two patches coming into contact with each other. After resuscitation, the pair must be discarded and replaced, respecting the expiry date printed on the packaging. Indicated for adult patients (over 8 years old or weighing more than 25 kg).
3. Technical Specifications
Main features of the series of adult radiotransparent electrodes with internal cable to which this reference belongs (Ref. Cahnos F7756):
| Parameter | Specification |
| Reference Cahnos (SKU) | F7756 |
| Product type | Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable |
| Brand / compatible equipment | Schiller – FRED Easy, FRED Easy 2G, FRED Easy Life, Defigard DG 4000, DG 5000 and DG 6002 |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | Integrated internal cable (direct connection to the equipment’s electrode socket), 100 cm |
| Radiotransparency | Yes (electrode and cable), suitable for imaging procedures |
| Total surface per electrode | 136 cm² (adult series) |
| Active surface per electrode | 94 cm² (adult series) |
| Adhesive ring width | 0.7 cm |
| Supported shocks | Up to 50 shocks at 360 J |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector, with internal cable |
| ECG monitoring | Up to 24 hours |
| Use | Single-use, disposable, non-sterile |
| Composition | Latex-free and phthalate-free |
| Primary packaging | 1 pair in heat-sealed polyethylene and aluminium bag |
| Sales format | Price per pair (2 units); 10 pairs per box (adult series) |
| Operating temperature | Between 0 °C and +50 °C |
| Storage | Dry place, between +5 °C and +35 °C |
| Shelf life | 30 months from production date (expiry on packaging) |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
Compatibility with Schiller defibrillators
| Equipment brand | Compatible models |
| Schiller | FRED Easy, FRED Easy 2G, FRED Easy Life, Defigard DG 4000, Defigard DG 5000, Defigard DG 6002 |
| Not compatible | FRED easyport / easyport plus (different connector; verify before purchase), FRED classic and Defigard DG 1002/3002 (require the connector generation of the F7754 family) |
Note: the surface values (136/94 cm²), adhesive ring (0.7 cm) and shocks (50 x 360 J) correspond to the adult radiotransparent series with internal cable of this electrode family; confirm with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
4. Equivalences and Cross-References
Reference F7756 is the Cahnos distribution code for this adult radiotransparent electrode compatible with Schiller; it is not an official reference of the equipment manufacturer. The connector and energy management of each defibrillator are proprietary, so equivalences with other references are considered comparable at category level and not interchangeable 1:1. The following cross-references have a consistently confirmed code in authorised distribution catalogues of original Schiller spare parts:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Schiller | Original pre-connected adult electrodes for FRED Easy and Defigard (internal cable) | 0-21-0020 (also 2.230344) | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised distribution (defibshop, veromedical, euroenergy, hayes): adult pair for FRED Easy / FRED Easy Ethernet / Defigard DG 4000, DG 5000 and DG 6002, with pre-connected cable. The radiotransparent nature of the original has not been confirmed in public sources. Verify connector, dimensions and technical data sheet before replacement. |
| Schiller | Original paediatric electrodes for FRED Easy and Defigard | 0-21-0037 (also 2.230347) | Comparable by category (not interchangeable 1:1) | Paediatric reference of the same equipment family; for contrast reference only, not suitable for adult patients. Code confirmed in authorised distribution; radiotransparency not verified. |
There is no equivalence table validated by the manufacturer that authorises the replacement of original Schiller electrodes with third-party patches: the connector, analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator; consult the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
Confirm the equipment model: this electrode is indicated for FRED Easy, FRED Easy 2G, FRED Easy Life and Defigard DG 4000, DG 5000 and DG 6002. Always check the fit of the internal cable connector into the electrode socket of the defibrillator before clinical use. The FRED easyport/easyport plus models and the classic FRED / Defigard DG 1002-3002 generation use a different connector and require other electrode families (F7967 or F7754).
Select according to the patient: this reference is for adults (over 8 years old or more than 25 kg). For paediatric patients of the same connector family, reference F7756P is available (radiotransparent paediatric with internal cable, with smaller active surface and reduced energy).
Choose radiotransparent when imaging tests are anticipated: if the patient may require X-ray, fluoroscopy or CT during care, this version avoids artefacts without removing the electrode. If imaging is not required, the standard version with internal cable (F7956) or with external cable (F7956W) may be considered, at lower cost, with the same equipment compatibility.
Check the expiry date and store correctly: store in a dry place between +5 °C and +35 °C and respect the date printed on the packaging; the conductive gel may dry out and lose conductivity after the expiry date. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock by expiry date (FIFO). For volume orders or tenders, contact the technical department of Cahnos stating the exact model and serial number of your equipment.