Standard adult defibrillator electrode with internal cable (pair) – Compatible replacement Philips Heartstream ForeRunner AED, HeartStart FR AED/FR2/FR3 and CodeMaster family · Ref. F7950

27,25 €

Standard adult defibrillator electrode pair with internal cable (ref. F7950), compatible replacement for Philips Heartstream ForeRunner AED, HeartStart FR AED/FR2/FR2+/FR3 and the CodeMaster family. Single-use multifunction electrodes for patients over 8 years or over 25 kg: low-impedance adhesive gel, metal foil and 1 mm medical foam backing; 148 cm² total surface and 95 cm² active area, up to 50 shocks at 360 J and ECG monitoring for up to 24 h. 120 cm internal cable, latex-free and phthalate-free, CE Class IIb medical device. Sold per pair (2 units) with immediate dispatch.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7950

Description

1. Commercial Introduction

Keep your Philips defibrillator always operational with this pair of standard adult defibrillator electrodes with internal cable (reference Cahnos F7950), a highly reliable replacement consumable compatible with the most widespread Philips AED and defibrillator-monitor families in Spain: Heartstream ForeRunner AED (models E, S and EM), HeartStart FR AED, FR2 and FR2+, FR3, OnSite, the CodeMaster family and the HeartStart 4000, XL/XLT and MRx equipment.

It is the indicated solution for emergency services, ICUs, ambulances, health centres, companies and any heart-protected space with Philips equipment. Its configuration with integrated internal cable connects the pair directly to the device’s electrode socket, without loose cables during resuscitation: at the critical moment you only need to remove the protector and place the patches following the anatomical diagrams on the packaging. Available with immediate shipping from Cahnos and specialised technical support to verify compatibility by model and connector.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and, depending on the model, allows synchronized cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency electrocardiogram monitoring. This adult model is indicated for patients over 8 years of age or weighing more than 25 kg.

The low-impedance conductive adhesive gel ensures homogeneous contact with the skin and optimal energy transmission; the internal metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), so that both patches do not come into contact with each other. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical specifications and compatibility

3.1 Technical specifications

Parameter Specification
Reference Cahnos (SKU) F7950
Product type Pair of standard multifunction adult defibrillator electrodes with internal cable (leads-in)
Patient type Adult (older than 8 years / more than 25 kg)
Cable configuration Integrated internal cable, 120 cm
Total surface (per electrode) 148 cm²
Active surface (per electrode) 95 cm²
Adhesive ring width 1.3 cm
Backing material Medical foam (1 mm thick)
Conductive material Metal foil
Conductive gel Low-impedance adhesive hydrogel
Maximum energy 360 J
Supported shocks Up to 50 shocks (50 to 360 J)
Functions External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring
ECG monitoring Up to 24 hours
Connection type Standard safety anti-shock connector (Philips / Agilent platform)
Presentation 1 pair in heat-sealed polyethylene and aluminium bag · 10 pairs per box
Composition Latex-free and phthalate-free · Single-use
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards IEC/EN 60601-1; IEC/EN 60601-2-4; ANSI/AAMI DF-80; ISO 10993-1
Shelf life 24 months from date of manufacture (expiry indicated on packaging)
Storage Cool, dry place, between +10 °C and +25 °C; operating from 0 °C to +50 °C

3.2 Compatibility with defibrillators

Equipment family / model Factory reference Observations
Heartstream ForeRunner AED (E, S, EM) — Direct connection
HeartStart FR1 AED 940010XX, 940020XX, 940030XX Direct connection
HeartStart FR2 AED M3840A, M3841A Direct connection
HeartStart FR2 with ECG module M3860A, M3861A Direct connection
HeartStart FR3 / HeartStart OnSite — Direct connection; on FR3 do not leave the electrodes connected in standby or off
Philips CodeMaster 100 M2475B With Philips M3507A cable and 05-200 adapter
Philips CodeMaster XE M1724A Direct connection
Philips CodeMaster XL / XL+ M1723A/B · M1722A/B Direct connection
HeartStart 4000 M5500B With Philips M3508A cable; energy in manual setting
Agilent-Philips HeartStart XL M4735A With Philips M3508A cable
Agilent-Philips HeartStart XLT M3500B With Philips M3508A cable
HeartStart MRx M3535A / M3536A With Philips M3508A cable; do not use in fully automatic mode
Philips Efficia DFM100 — Direct connection
Laerdal AED Trainer 2 — Direct connection (training)

Technical note: always verify the correct fit of the connector and cable of your device before clinical use. Compatibility refers to the connector platform of each family.

4. Equivalences and Cross-References

Reference F7950 is the Cahnos distribution code for this compatible electrode: it is not an original reference certified by Philips. The equivalence with the official nomenclature of the device manufacturer corresponds to the Philips multifunction electrode family with barrel connector (M3501A / M3502A and alternative codes 989803106921 / 989803106931), documented in Philips technical documentation and regulatory databases. Any comparison between brands should be understood as comparable at category level, not 1:1 interchangeable.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Philips Healthcare Adult/Child Pads with barrel connector (original multifunction electrodes for the CodeMaster / HeartStream / HeartStart family) M3501A (also 989803106921) Comparable by category (not interchangeable 1:1) Factory original from the same connector platform Philips; covers adult and adult/child population (≥10 kg) and requires the M3507A/M3508A cables depending on the model. Code confirmed in Philips technical documentation and authorised distribution.
Philips Healthcare Adult Multifunction Pads, IEC barrel connector M3502A (also 989803106931) Comparable by category (not interchangeable 1:1) Factory original for the CodeMaster 100 (M2475B), XE (M1724A), XL/XL+ (M1723A/B, M1722A/B), HeartStart 4000 (M5500B), XL (M4735A), XLT (M3500B) and MRx (M3535A/M3536A) families. Code confirmed in authorised technical distribution; verify connector, surface and cable before replacement.
Philips Healthcare HeartStart Adult Defibrillator Pads (AED FR2/FR2+ / ForeRunner) 989803158211 (1 pair) / 989803158221 (5 pairs) Comparable by category (not interchangeable 1:1) Original for the AEDs of the HeartStart FR2/FR2+ and ForeRunner family, for patients ≥8 years or ≥25 kg; code confirmed on the official Philips website and in GUDID (DI 00884838023710 / 00884838126299). Proprietary connector and algorithm from the same AED platform.
Cardinal Health (Medi-Trace™ Cadence) Adult Multi-Function Defibrillation Electrodes, radiolucent, Philips barrel connector 22661R (preconnected: 22661PC) Comparable by category (not interchangeable 1:1) Radiolucent adult pair with barrel connector compatible with the Philips/Agilent-HP family; silver/silver chloride gradient technology and 10 pairs per box. Code confirmed in GUDID (DI 20884527022370) and the manufacturer’s catalogue. Verify connector and surfaces before replacement.
Nissha Medical Technologies (HeartSync) 97-DEFIB F/G C100AC-PHILIPS 6600015H Comparable by category (not interchangeable 1:1) Radiolucent adult pair with internal cable and connector comparable to the original Philips; 1.5 m cable and 36-month service life. Code confirmed in the manufacturer’s official catalogue. Verify connector and compatibility with the exact model of the equipment.

There is no equivalence table validated by the manufacturer that authorises the replacement of original Philips electrodes with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the equipment connector, the energy range, the target population and the expiry date of the packaging. Consult the technical department of Cahnos before using in tenders.

5. Selection tips and variants of interest

  • Confirm the equipment model: verify on the defibrillator plate the exact model (ForeRunner AED, FR AED/FR2/FR2+/FR3, CodeMaster 100/XE/XL/XL+ or HeartStart 4000/XL/XLT/MRx) and the required therapy cable (M3507A or M3508A on models that require it) before storing the spare part.
  • Do not confuse internal and external cable: this reference connects via integrated internal cable. If your workflow requires leaving the pair preconnected with the connector accessible, you have the external cable variant of the same platform (F7950W).
  • Paediatric version: for patients under 8 years or under 25 kg use the paediatric reference with internal cable F7950P (or the radiolucent F7750P), and for the paediatric provision of the HeartStart FR2/FR2+ AEDs the limited-energy references F7950PL / F7950WPL.
  • Standard vs. radiolucent electrode: if the patient may require X-ray, fluoroscopy or CT during care, consider the radiolucent series of the same family (F7750), which avoids image artefacts without removing the electrode.
  • Storage and expiry: store in a cool, dry place between +10 °C and +25 °C and respect the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. Do not use expired electrodes or those with damaged pouch.
  • Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to expiry date (FIFO). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your equipment.

Additional information

Product type

Pair of standard multifunction adult defibrillator electrodes with internal cable (leads-in)

Compatibility

Philips / Agilent-Philips (Heartstream, HeartStart and CodeMaster family)

Patient type

Adult (older than 8 years / more than 25 kg)

Cable configuration

Integrated internal cable, 120 cm

Total surface

148 cm² per electrode

Active surface

95 cm² per electrode

Adhesive ring width

1.3 cm

Supported shocks

Up to 50 shocks (50 to 360 J)

Functions

External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring

ECG monitoring

Up to 24 hours

Conductive gel

Low-impedance adhesive hydrogel

Conductive material

Metal foil

Backing material

Medical foam (1 mm thick)

Connection type

Standard safety anti-shock connector (Philips / Agilent platform)

Use

Single-use, disposable; latex-free and phthalate-free

Presentation

10 pairs per box (1 pair in heat-sealed bag)

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

IEC/EN 60601-1; IEC/EN 60601-2-4; ANSI/AAMI DF-80; ISO 10993-1

Shelf life

24 months from date of manufacture (expiry on packaging)

Storage

Cool, dry place, +10 °C to +25 °C; operating 0 °C to +50 °C