Keep your Philips defibrillator always operational with this pair of standard adult defibrillator electrodes with internal cable (reference Cahnos F7950), a highly reliable replacement consumable compatible with the most widespread Philips AED and defibrillator-monitor families in Spain: Heartstream ForeRunner AED (models E, S and EM), HeartStart FR AED, FR2 and FR2+, FR3, OnSite, the CodeMaster family and the HeartStart 4000, XL/XLT and MRx equipment.
It is the indicated solution for emergency services, ICUs, ambulances, health centres, companies and any heart-protected space with Philips equipment. Its configuration with integrated internal cable connects the pair directly to the device’s electrode socket, without loose cables during resuscitation: at the critical moment you only need to remove the protector and place the patches following the anatomical diagrams on the packaging. Available with immediate shipping from Cahnos and specialised technical support to verify compatibility by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and, depending on the model, allows synchronized cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency electrocardiogram monitoring. This adult model is indicated for patients over 8 years of age or weighing more than 25 kg.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin and optimal energy transmission; the internal metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), so that both patches do not come into contact with each other. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical specifications and compatibility
3.1 Technical specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7950 |
| Product type | Pair of standard multifunction adult defibrillator electrodes with internal cable (leads-in) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | Integrated internal cable, 120 cm |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1.3 cm |
| Backing material | Medical foam (1 mm thick) |
| Conductive material | Metal foil |
| Conductive gel | Low-impedance adhesive hydrogel |
| Maximum energy | 360 J |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Functions | External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring |
| ECG monitoring | Up to 24 hours |
| Connection type | Standard safety anti-shock connector (Philips / Agilent platform) |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium bag · 10 pairs per box |
| Composition | Latex-free and phthalate-free · Single-use |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | IEC/EN 60601-1; IEC/EN 60601-2-4; ANSI/AAMI DF-80; ISO 10993-1 |
| Shelf life | 24 months from date of manufacture (expiry indicated on packaging) |
| Storage | Cool, dry place, between +10 °C and +25 °C; operating from 0 °C to +50 °C |
3.2 Compatibility with defibrillators
| Equipment family / model | Factory reference | Observations |
|---|---|---|
| Heartstream ForeRunner AED (E, S, EM) | — | Direct connection |
| HeartStart FR1 AED | 940010XX, 940020XX, 940030XX | Direct connection |
| HeartStart FR2 AED | M3840A, M3841A | Direct connection |
| HeartStart FR2 with ECG module | M3860A, M3861A | Direct connection |
| HeartStart FR3 / HeartStart OnSite | — | Direct connection; on FR3 do not leave the electrodes connected in standby or off |
| Philips CodeMaster 100 | M2475B | With Philips M3507A cable and 05-200 adapter |
| Philips CodeMaster XE | M1724A | Direct connection |
| Philips CodeMaster XL / XL+ | M1723A/B · M1722A/B | Direct connection |
| HeartStart 4000 | M5500B | With Philips M3508A cable; energy in manual setting |
| Agilent-Philips HeartStart XL | M4735A | With Philips M3508A cable |
| Agilent-Philips HeartStart XLT | M3500B | With Philips M3508A cable |
| HeartStart MRx | M3535A / M3536A | With Philips M3508A cable; do not use in fully automatic mode |
| Philips Efficia DFM100 | — | Direct connection |
| Laerdal AED Trainer 2 | — | Direct connection (training) |
Technical note: always verify the correct fit of the connector and cable of your device before clinical use. Compatibility refers to the connector platform of each family.
4. Equivalences and Cross-References
Reference F7950 is the Cahnos distribution code for this compatible electrode: it is not an original reference certified by Philips. The equivalence with the official nomenclature of the device manufacturer corresponds to the Philips multifunction electrode family with barrel connector (M3501A / M3502A and alternative codes 989803106921 / 989803106931), documented in Philips technical documentation and regulatory databases. Any comparison between brands should be understood as comparable at category level, not 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips Healthcare | Adult/Child Pads with barrel connector (original multifunction electrodes for the CodeMaster / HeartStream / HeartStart family) | M3501A (also 989803106921) | Comparable by category (not interchangeable 1:1) | Factory original from the same connector platform Philips; covers adult and adult/child population (≥10 kg) and requires the M3507A/M3508A cables depending on the model. Code confirmed in Philips technical documentation and authorised distribution. |
| Philips Healthcare | Adult Multifunction Pads, IEC barrel connector | M3502A (also 989803106931) | Comparable by category (not interchangeable 1:1) | Factory original for the CodeMaster 100 (M2475B), XE (M1724A), XL/XL+ (M1723A/B, M1722A/B), HeartStart 4000 (M5500B), XL (M4735A), XLT (M3500B) and MRx (M3535A/M3536A) families. Code confirmed in authorised technical distribution; verify connector, surface and cable before replacement. |
| Philips Healthcare | HeartStart Adult Defibrillator Pads (AED FR2/FR2+ / ForeRunner) | 989803158211 (1 pair) / 989803158221 (5 pairs) | Comparable by category (not interchangeable 1:1) | Original for the AEDs of the HeartStart FR2/FR2+ and ForeRunner family, for patients ≥8 years or ≥25 kg; code confirmed on the official Philips website and in GUDID (DI 00884838023710 / 00884838126299). Proprietary connector and algorithm from the same AED platform. |
| Cardinal Health (Medi-Trace™ Cadence) | Adult Multi-Function Defibrillation Electrodes, radiolucent, Philips barrel connector | 22661R (preconnected: 22661PC) | Comparable by category (not interchangeable 1:1) | Radiolucent adult pair with barrel connector compatible with the Philips/Agilent-HP family; silver/silver chloride gradient technology and 10 pairs per box. Code confirmed in GUDID (DI 20884527022370) and the manufacturer’s catalogue. Verify connector and surfaces before replacement. |
| Nissha Medical Technologies (HeartSync) | 97-DEFIB F/G C100AC-PHILIPS | 6600015H | Comparable by category (not interchangeable 1:1) | Radiolucent adult pair with internal cable and connector comparable to the original Philips; 1.5 m cable and 36-month service life. Code confirmed in the manufacturer’s official catalogue. Verify connector and compatibility with the exact model of the equipment. |
There is no equivalence table validated by the manufacturer that authorises the replacement of original Philips electrodes with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the equipment connector, the energy range, the target population and the expiry date of the packaging. Consult the technical department of Cahnos before using in tenders.
5. Selection tips and variants of interest
- Confirm the equipment model: verify on the defibrillator plate the exact model (ForeRunner AED, FR AED/FR2/FR2+/FR3, CodeMaster 100/XE/XL/XL+ or HeartStart 4000/XL/XLT/MRx) and the required therapy cable (M3507A or M3508A on models that require it) before storing the spare part.
- Do not confuse internal and external cable: this reference connects via integrated internal cable. If your workflow requires leaving the pair preconnected with the connector accessible, you have the external cable variant of the same platform (F7950W).
- Paediatric version: for patients under 8 years or under 25 kg use the paediatric reference with internal cable F7950P (or the radiolucent F7750P), and for the paediatric provision of the HeartStart FR2/FR2+ AEDs the limited-energy references F7950PL / F7950WPL.
- Standard vs. radiolucent electrode: if the patient may require X-ray, fluoroscopy or CT during care, consider the radiolucent series of the same family (F7750), which avoids image artefacts without removing the electrode.
- Storage and expiry: store in a cool, dry place between +10 °C and +25 °C and respect the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. Do not use expired electrodes or those with damaged pouch.
- Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to expiry date (FIFO). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your equipment.