Description
1. Commercial Introduction
Keep your Physio-Control defibrillator or monitor always ready for cardiac pacing with this pair of external pacing electrodes for adults (reference FIAB F7973). It is the specific consumable for the Physio-Control platform for the pacemaker function, designed together with cable and connector for a fast, stable and safe connection at the critical moment.
Manufactured by FIAB SpA (Vicchio, Florence, Italy), European leader in electrodes for defibrillation and pacing, this pair is intended for emergency services, intensive care units, ambulances and healthcare centres that treat adult patients with symptomatic bradyarrhythmias or cardiac arrest.
2. Technical explanation of the procedure
External cardiac pacing electrodes are the interface between the defibrillator’s external pacemaker and the patient: through them, low-energy electrical impulses are delivered that stimulate myocardial contraction transcutaneously and non-invasively, without the need for an intracavitary route. This technique, called transcutaneous pacing or external pacemaker, is an essential bridge manoeuvre in the management of severe bradycardias with haemodynamic instability while a permanent pacemaker is being prepared.
The F7973 pair is indicated for adult patients and connects to the Physio-Control device via its specific cable and connector. The conductive adhesive gel ensures a homogeneous, low-impedance contact with the skin, essential for the pacing impulses to be transmitted correctly and with the least possible discomfort. They are single-use: they must be removed after each procedure and replaced according to the expiry date on the packaging.
3. Technical Specifications
Product features according to the FIAB manufacturer’s catalogue (fiab.it, Defibrillation > Stimulation Pads section):
| Available references | |
|---|---|
| Characteristic | Value |
| Reference FIAB | F7973 |
| Packaging | 10 pairs per box |
| Units per box (web) | 10 |
| Compatible with | Physio-Control |
| Additional data | |
|---|---|
| Characteristic | Value |
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Pair of adult external cardiac stimulation electrodes, with cable and connector |
| Population | Adult |
| Function | Non-invasive transcutaneous pacing (external pacemaker / pacing) in Physio-Control equipment |
| Cable and connector | Included |
| Use | Single-use, disposable |
| Commercialisation | Sold in complete boxes; product on quotation |
4. Equivalences and Cross-References
This product corresponds to reference F7973 in the FIAB catalogue for the Physio-Control connector platform, also identified as FIAB-F7973 in the Cahnos catalogue. Within the same FIAB family of pacing electrodes, the following related references are available:
| Reference FIAB | Description | Related items |
|---|---|---|
| F7973 | Adult pair, with cable and connector, for Physio-Control | Main reference (this product) |
| F7951/STIM | Adult pair, with cable and connector, for Zoll (M Series, pacer version) | Another platform (different connector) |
| F7951P/STIM | Paediatric pair, with cable and connector, for Zoll (M Series, pacer version) | Another platform (different connector) |
| F7955/STIM | Adult pair for Nihon Kohden and Innomed equipment | Another platform (different connector) |
No equivalences with original Physio-Control codes are included as they have not been verified in reliable available sources. Remember that the connector, algorithm and energy management are proprietary to each manufacturer: before replacing an original electrode, always validate compatibility with the technical data sheet and instructions for use of your defibrillator. Do not assume interchangeability between platforms: each FIAB pacing reference is designed for a specific connector system.
5. Selection tips and variants of interest
Confirm that your device has a pacemaker function: this electrode is specific for external pacing in Physio-Control equipment. Check the model and serial number on the device plate, as well as the correct fit of the connector, before clinical use.
Do not confuse pacing and defibrillation: for delivering defibrillation shocks in Physio-Control equipment, other references from the multifunction and defibrillation electrode family are available. This pair is designed exclusively for external pacing.
Population: it is indicated for adult patients. If you treat paediatric patients, consult our technical department for the paediatric variants of the FIAB pacing family.
Stock management: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method). Store in a dry place, in its original packaging and away from direct light.
For volume orders, tenders or compatibility queries, contact the technical-commercial department of Cahnos, stating the exact model and serial number of your device.