Description
1. Commercial Introduction
Keep your Philips defibrillator always ready to act with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7950W), a replacement consumable compatible with equipment from the HeartStream ForeRunner, HeartStart FR2 and CodeMaster families. It is the recommended solution for emergency services, ambulances, health centres, companies and any heart-safe space equipped with Philips.
Thanks to its configuration with an external cable, the connector remains accessible without opening the sealed pouch: the pair can be left pre-connected to the device and, at the critical moment, you only need to remove the protective cover and place the pads following the anatomical diagrams on the packaging, minimising preparation time. It is sold as a pair (2 units) with immediate dispatch and specialised technical support from Cahnos.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the biphasic transthoracic shock and enables emergency electrocardiogram monitoring. This pair is indicated for adult patients (over 8 years old or weighing more than 25 kg) for defibrillation, synchronised cardioversion and ECG monitoring.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), according to the diagrams on the packaging. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Features of the series of standard adult electrodes with external cable to which this reference belongs:
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7950W |
| Product type | Pair of standard multifunction adult defibrillator electrodes with external cable (lead-out) |
| Brand / compatible equipment | Philips – HeartStream ForeRunner, HeartStart FR2 and CodeMaster family; check the connector fits into the device socket |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | External cable (pre-connected connection), approximate length 120–130 cm in the series |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Functions | Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (1 mm thick) |
| Connection type | Anti-shock safety connector, external cable |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Shelf life | Approx. 30 months from the date of manufacture; expiry date indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
| Presentation | Price per pair of electrodes (2 units); 1 pair in a heat-sealed polyethylene and aluminium bag (10 pairs per box in the adult series) |
Compatible equipment (compatibility declared by the distributor):
| Brand | Compatible models |
|---|---|
| Philips | HeartStream ForeRunner |
| Philips | HeartStart FR2 |
| Philips | CodeMaster family (100, XE, XL, XL+) |
Technical note: the values for active surface (95 cm²), total area (148 cm²), discharges (50 to 360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with external cable in this product family; confirm them with the technical data sheet of the supplied batch and the device manual before use in tendering. Always check the connector fit and the hands-free cable of your device before clinical use.
4. Equivalences and Cross-References
The reference F7950W is a consumable compatible with the aforementioned Philips defibrillators, not a certified original spare part: the connector, the analysis algorithm and energy management are proprietary to each defibrillator. The equivalence with the manufacturer’s official nomenclature corresponds to the Philips multifunction electrode family with barrel connector (M3501A and alternative code 989803106921), documented in the Philips technical specification sheet and at authorised distributors of original spare parts. The references from other brands listed below share the same type (adult multifunction defibrillator electrode) and are classified as comparable by category, not 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips | Adult/Child Pads with barrel connector – original multifunction electrodes from the CodeMaster / HeartStream / HeartStart family | M3501A (also 989803106921) | Comparable by category (not interchangeable 1:1) | Factory original from the same Philips connector platform; covers adult and adult/child populations (≥10 kg) and requires the M3507A/M3508A cables depending on the model. Code documented in the Philips technical specification sheet and authorised distributors; there is no Philips validation authorising the replacement of the original with the compatible spare part F7950W. |
| ZOLL Medical | Stat-Padz® II (adult multifunction electrodes) | 8900-0801-01 | Comparable by category (not interchangeable 1:1) | Factory original pre-connected for AED Plus and AED Pro (without external cable); proprietary ZOLL connector and own energy levels. Not suitable for Philips equipment due to proprietary connector. |
| Cardiac Science (ZOLL) | Powerheart® Adult Defibrillation Pads | 9131-001 | Comparable by category (not interchangeable 1:1) | Factory original for the Powerheart 9200/9300 families (G3, G3 Plus, G3 Pro) and GE Responder AED; proprietary connector. Code verified in GUDID/FDA and in the official ZOLL store. |
| Defibtech | Lifeline DDU-100 / DDU-120 Adult Rescue Pads | DDP-100 | Comparable by category (not interchangeable 1:1) | Adult electrodes for Lifeline AEDs (preconnected); proprietary Defibtech connector, algorithm and electronics; not interchangeable with Philips equipment. |
There is no equivalence table validated by Philips that authorises the replacement of the original electrodes with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department of Cahnos before use in a tender. Within the Cahnos catalogue there are other references in the same family (standard adult with external cable) intended for equipment from other manufacturers, not interchangeable with each other as the connector and algorithm differ: F7951W (ZOLL Medical), F7957W (Cardiac Science / GE Responder), F7959W (CU Medical i-PAD), F7967W (Schiller) and F7987W (ZOLL AED).
5. Selection tips and variants of interest
Confirm the equipment model: this pair corresponds to the Philips HeartStream ForeRunner, HeartStart FR2 and CodeMaster family defibrillators. Verify that the external cable connector fits correctly into the electrode socket and into the hands-free cable of your equipment before clinical use; it is not valid for equipment with a different connector without prior validation.
Do not confuse versions: this pair is for adult patients. For the paediatric population with the same family of Philips connectors, references F7950PW (external cable, original function M3504A) and F7950P (internal cable) are available; for the paediatric kit of the HeartStart FR2/FR2+ AEDs, use the limited-energy references F7950WPL and F7950PL (150 J → 50 J reduction of the original M3870A). The adult variant with internal cable in this same family is supplied under reference F7950.
Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or those with a damaged pouch, as the gel may lose conductivity.
Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO). For volume orders or tenders, contact the technical-commercial department of Cahnos stating the exact model and serial number of your defibrillator.