Standard adult defibrillator electrodes with internal cable (pair) – Multi-brand replacement compatible with Nihon Kohden Cardiolife TEC, Welch Allyn AED/PIC, Artema CardioAid, Dräger Cardiolog 2000 and MRL – Ref. F7955

27,25 €

Standard adult defibrillator electrode pair with internal cable (Ref. F7955), multi-brand replacement that covers with a single reference the installed bases of Nihon Kohden Cardiolife TEC (cables JC-755V and K342A/JC-855V), Welch Allyn (AED-10, AED-20 and PIC-30/40/50), Artema Innomed and Artema S&W (CardioAid), Dräger (Cardiolog 2000) and MRL (LITE and Life Quest). Disposable single-use multifunction electrodes with low-impedance conductive adhesive gel, metal foil and 1 mm medical foam backing: active surface area of 95 cm² per electrode, up to 50 discharges at 360 J and ECG monitoring for up to 24 h. The anti-shock connector with integrated internal cable protects the connection until the moment of use. Latex and phthalate-free; Class IIb medical device. Sold per pair with immediate shipping and technical support to verify compatibility by model and connector.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7955

Description

1. Introduction

Keep your defibrillator always operational with this pair of standard adult defibrillator electrodes with internal cable (Ref. Cahnos F7955), a multi-compatibility replacement consumable designed for equipment from the Nihon Kohden Cardiolife TEC, Welch Allyn AED/PIC, Artema Innomed and Artema S&W CardioAid, Dräger Cardiolog 2000 and MRL families. With a single reference you can cover the main defibrillator fleets on the market, simplifying the stock of consumables for emergency departments, ICUs, ambulances, health centres and heart-safe spaces. Its configuration with integrated internal cable protects the connector and cable inside the heat-sealed bag until the moment of use, guaranteeing the integrity and functional sterility of the gel. Available with immediate dispatch from Cahnos and specialised technical assistance for compatibility verification by model and connector.

2. Technical Explanation

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the biphasic transthoracic shock and enables emergency ECG monitoring. This pair is indicated for external defibrillation, synchronised cardioversion and ECG monitoring (up to 24 h) in adult patients, considered as those over 8 years of age or weighing more than 25 kg. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns. The internal cable configuration leaves the pad ready for direct and stable connection to the device’s electrode socket after opening the packaging, without loose cables during resuscitation. They are strictly for single-patient use: after resuscitation they must be disposed of and replaced, always respecting the expiry date printed on the packaging.

3. Technical specifications and compatibility

3.1 Technical specifications

Parameter Specification
Reference Cahnos (SKU) F7955
Patient type Adult (older than 8 years / more than 25 kg)
Product type Pair of adult multifunction defibrillator electrodes, standard, with internal cable
Cable configuration Integrated internal cable (direct connection to the equipment electrode socket)
Total surface (per electrode) 148 cm²
Active surface (per electrode) 95 cm²
Adhesive ring width 1 cm
Supported shocks Up to 50 shocks (50 to 360 J)
Functions Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material 1 mm thick medical foam
Connection type Safety anti-shock connector with internal cable
Use Single-use, disposable, non-sterile; latex-free and phthalate-free
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10
Shelf life Approx. 30 months from the date of manufacture; expiry date indicated on the packaging
Storage Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C
Presentation Price per pair of electrodes (2 units); 1 pair in heat-sealed polyethylene and aluminium bag (10 pairs per box in adult series)

Note: the values for active surface (95 cm²), total area (148 cm²), discharges (50 to 360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable of this product family; confirm with the technical data sheet of the supplied batch and the equipment manual before use in tenders.

3.2 Compatibility with defibrillators

Equipment brand Compatible models Cable / required accessories
Nihon Kohden Cardiolife TEC-5500 Series, TEC-5600 Series, TEC-7600 Series, TEC-7700 Series, TEC-2202, TEC-2203, TEC-7531, TEC-8251 and TEC-8300 Series Cable JC-755V (TEC-5500, TEC-7600, TEC-7700, TEC-2202, TEC-2203, TEC-7531, TEC-8251) · Cable K342A / JC-855V (TEC-5600, TEC-8300)
Welch Allyn AED-10, AED-20, PIC-30, PIC-40 and PIC-50 Paediatric adapter Welch Allyn 002173-U (AED-10) · Paediatric adapter Welch Allyn 002174-U (AED-20)
Artema Innomed CardioAid 360B, CardioAid 200B, CardioAid 200, CardioAid 100, CardioAid XL+ and CardioAid XL Safety anti-shock connector
Artema S&W CardioAid LS, CardioAid MC and CardioAid MC+ Safety anti-shock connector
Dräger Cardiolog 2000 Safety anti-shock connector
MRL LITE and Life Quest Safety anti-shock connector

Note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your device before clinical use.

4. Equivalences and Cross-References

Reference F7955 is a consumable compatible with the cited defibrillators, and not an original spare part certified by each equipment manufacturer: the connector and energy management of each defibrillator are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID/FDA, EUDAMED), the following cross-references with confirmed codes in public sources are identified. In no case is there an official equivalence table validated by the manufacturer for this reference.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nihon Kohden Disposable adult/child/infant pad (original equipment) P-740K Comparable by category (not interchangeable 1:1) Code confirmed in official Nihon Kohden documentation and authorised distribution: factory original with 1.5 m cable; covers AED-2100 series, AED-3100 and TEC-5500/5600/7600/7700/8300 series. Own connector, gel and labelling; the cable is inside the packaging. Verify connector fit before replacement.
Nihon Kohden Disposable AED adult/child pad (original TEC-8300K / TEC-8342) P-711 (order code H329) Comparable by category (not interchangeable 1:1) Code confirmed on the official Nihon Kohden Europe website and authorised distribution: original with 1.5 m cable, aimed at the Cardiolife AED and TEC-8300 families (including TEC-8342). Proprietary connector; verify compatibility before replacement.
Welch Allyn (AED line) Original adult pad for AED-10 and AED-20 001855-U (1855-U) Comparable by category (not interchangeable 1:1) Original reference confirmed in authorised technical distribution: adult pair with cable inside the packaging for AED-10 and AED-20. Shares AED-10/20 platform but is not 1:1 interchangeable due to cable and connector configuration.
Nissha Medical Technologies (HeartSync) Defibrillation pads compatible with Nihon Kohden TEC-5500/5600/7600/7700/8300 T100AC-NIHONKOHDEN (ref. 6600265H) Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: radiolucent adult pair with a total surface area of 371 cm², integrated 2 m cable inside the packaging and connector comparable to the original Nihon Kohden; for TEC-5500/7700 requires adapter cable JC-765V. Presentation, areas and cable configuration differ from this reference; verify connector and cable (JC-755V / K342A-JC-855V depending on series) before replacement.

For Dräger Cardiolog 2000, MRL LITE / Life Quest and Artema CardioAid equipment, no verifiable original electrode code has been found in public sources, so the equivalences for those families remain pending confirmation with the manufacturer. The original paediatric adapters Welch Allyn 002173-U (AED-10) and 002174-U (AED-20) consistently appear in the manufacturer’s documentation and are the required accessories for paediatric use on those devices.

There is no equivalence table validated by the manufacturer that authorises the replacement of original electrodes with third-party pads: the connector and energy management of each defibrillator are proprietary. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator; consult the technical department of Cahnos before using in a tender.

5. Selection tips and variants of interest

  • Identify the model and cable of your equipment: in Nihon Kohden, the TEC-5600 and TEC-8300 series use the K342A / JC-855V cable, while the remaining series in the table use the JC-755V. Always check the connector fit before clinical use; in case of doubt, contact the technical department of Cahnos indicating the model and serial number.
  • Do not confuse the adult version with the paediatric version: this pair is for patients over 8 years old or over 25 kg. For paediatric patients on the same devices, the standard paediatric version of the same family is available (F7955P with internal cable and F7955PW with external cable), always with the energy reduction adapter required on Welch Allyn AED-10/AED-20 devices (002173-U or 002174-U).
  • Internal cable versus external cable: the internal cable configuration protects the connection inside the sealed pouch until the moment of opening; if you prefer to leave the device pre-connected and save seconds in an emergency, consider the standard external cable version of the same platform (F7955W).
  • If imaging tests are anticipated: for X-ray, fluoroscopy or CT during care, consider the radiolucent versions of the same family (F7755 with internal cable or F7755W with external cable), which avoid artefacts without removing the electrode.
  • Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the expiry date printed on the packaging; the conductive gel may dry out and lose conductivity after the expiry date. Do not use expired electrodes or those with damaged packaging.
  • Plan your replenishment: as it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to expiry (FIFO method). For volume orders or tenders, contact the technical department of Cahnos indicating the exact model and serial number of your defibrillator.

Additional information

Patient type

Adult (older than 8 years / more than 25 kg)

Product type

Pair of adult multifunction defibrillator electrodes, standard, with internal cable

Cable configuration

Integrated internal cable (direct connection to the equipment electrode socket)

Radiolucent

No (standard version)

Total surface per electrode

148 cm²

Active surface per electrode

95 cm²

Adhesive ring width

1 cm

Supported shocks

Up to 50 shocks (50 to 360 J)

Functions

Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam

Connection type

Safety anti-shock connector with internal cable

Compatibility

Nihon Kohden Cardiolife TEC (cables JC-755V and K342A/JC-855V), Welch Allyn AED-10/20 and PIC-30/40/50, Artema Innomed and Artema S&W CardioAid, Dräger Cardiolog 2000 and MRL (LITE, Life Quest)

Required accessories

Paediatric adapters Welch Allyn 002173-U (AED-10) and 002174-U (AED-20)

Use

Single-use, disposable, non-sterile; latex-free and phthalate-free

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Shelf life

Approx. 30 months from the date of manufacture; expiry date indicated on the packaging

Storage

Dry place, +5 °C to +35 °C; operation from 0 °C to +50 °C

Presentation

Price per pair (2 units); 1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series)