Description
1. Commercial Introduction
Keep your Instramed CardioMax defibrillator-monitor always ready to act with this pair of standard adult defibrillator electrodes with internal cable (reference Cahnos F7985). It is the replacement consumable indicated for the care of adult patients in emergency departments, ambulances, intensive care units, hospital wards and any clinical setting equipped with this platform: a single pair of disposable pads keeps the equipment operational and ready to respond quickly to a cardiorespiratory arrest.
Its configuration with integrated internal cable provides a direct and stable connection to the equipment’s electrode socket, without loose cables during resuscitation: at the critical moment you only need to remove the packaging protector and place the pads following the anatomical diagrams on the sachet. They are sold as a pair (2 units), individually packed in a heat-sealed polyethylene and aluminium bag and ready to be integrated into your centre’s defibrillation protocols.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and allows emergency electrocardiogram monitoring. This pair is indicated for adult patients (over 8 years old or over 25 kg) and is designed for the biphasic cardioversion defibrillator-monitor Instramed CardioMax with internal cable connection.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal foil distributes the current uniformly and the 1 mm medical foam (FOAM) support adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), according to the anatomical diagrams on the packaging. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
3.1 Product identification
| Reference Cahnos (SKU) | F7985 |
| Instramed factory code (original adult replacement, contrast reference) | 79047 (also CMAX8-79047 / AC00000100 in authorised distribution) |
| Product type | Pair of adult multifunction defibrillator electrodes, standard, with internal cable |
| Brand / compatible equipment | Instramed – CardioMax defibrillator-monitor (direct connection to the electrode socket, side of the unit) |
| Presentation | Price per pair (2 units); 1 pair in heat-sealed bag; 10 pairs per box (adult series) |
3.2 Technical features
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | Integrated internal cable (direct connection to the equipment electrode socket) |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (power from 50 to 360 J in adult configuration) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector with internal cable |
| ECG monitoring | Up to 24 h |
| Use | Single-use, disposable, non-sterile |
| Latex / phthalates | Latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Shelf life | Approx. 30 months from the date of manufacture; expiry date indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
3.3 Clinical applications
| Application | Description |
| External defibrillation | Treatment of severe arrhythmias via transthoracic electrical shock |
| Synchronized cardioversion | Correction of atrial or ventricular arrhythmias with ECG-synchronised shock |
| Non-invasive transcutaneous pacing | External pacemaker for symptomatic bradycardias or AV blocks (depending on equipment configuration) |
| ECG monitoring | Continuous recording of cardiac electrical activity without shock (max. 24 h) |
Note: the values for active surface area (95 cm²), total area (148 cm²), shocks (up to 360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable of this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
4. Equivalences and Cross-References
The reference F7985 is the Cahnos distribution code for this compatible electrode for the Instramed CardioMax platform. The code 79047 corresponds to the factory disposable adult multifunction electrode of the Instramed family (adult adhesive pad for CardioMax, DualMax, Apolus and the brand’s AEDs, documented in Instramed’s official store in Brazil and in authorised distribution) and is cited as a contrast reference for this compatible pad. The connector, analysis algorithm and energy management of each defibrillator are proprietary, so equivalences with other brands are comparable only at category level and are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Instramed (original equipment replacement) | Disposable adhesive adult pad – disposable multifunction electrode for CardioMax / DualMax / Apolus / AED | 79047 (CMAX8-79047 / AC00000100) | Comparable by category (not interchangeable 1:1) | Original factory replacement confirmed in Instramed’s official store and in authorised distribution; same compatibility declared in this data sheet. It is cited as a contrast reference for the compatible pad Cahnos F7985. Do not confuse with the paediatric electrode (79048). |
| ZOLL Medical | Stat-Padz® II – original adult electrodes (AED Plus / AED Pro) | 8900-0801-01 | Comparable by category (not interchangeable 1:1) | Factory original pre-connected with conductive hydrogel for the brand’s AEDs; code confirmed on the manufacturer’s website and GUDID. Proprietary connector, not suitable for Instramed equipment. |
| Defibtech | DDP-100 – original adult electrodes (Lifeline DDU-100 / DDU-120) | DDP-100 | Comparable by category (not interchangeable 1:1) | Original replacement from the Lifeline family for defibrillation and ECG monitoring; code cited as a contrast reference for the same clinical segment. Not interchangeable with the Instramed connector. |
| Philips | Adult/Child Pads with barrel connector (adult/child ≥ 10 kg) | M3501A / 989803106921 | Comparable by category (not interchangeable 1:1) | Original with barrel connector for the HeartStart MRx / XL / XL+ and CodeMaster family; requires M3507A/M3508A cables depending on equipment. Code confirmed in Philips technical documentation and GUDID; not suitable for Instramed equipment. |
There is no equivalence table validated by the manufacturer (Instramed) that authorises the substitution of the original electrodes with third-party pads for this reference: the connector, the analysis algorithm and the energy management of each defibrillator are proprietary. Any substitution must be validated against the technical data sheet and instructions for use of the defibrillator; consult the technical department of Cahnos before use in tenders. Within the Cahnos catalogue, the paediatric variant with internal cable for the CardioMax is the F7985P, the adult version with external cable for the same Instramed platform is the F7984W and its paediatric variant is the F7984PW.
5. Selection tips and variants of interest
- Confirm the equipment model: verify that your defibrillator is an Instramed CardioMax and that the internal cable connector fits correctly into the electrode socket of the equipment before clinical use; if in doubt, contact the technical department of Cahnos stating the model and serial number.
- Do not confuse adult and paediatric versions: this pair is for adult patients (over 8 years / more than 25 kg); for children with the same CardioMax use reference F7985P (paediatric with internal cable).
- If you prefer to leave the pair pre-connected: consider the adult variant with external cable F7984W for the same Instramed equipment family, which allows the connector to remain accessible and minimises preparation time.
- Check the expiry date: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity.
- Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO). For volume orders or tenders, contact the technical department of Cahnos stating the exact model and serial number of your defibrillator.







Reviews
There are no reviews yet.