Description
1. Commercial Introduction
Keep the electrocardiographic monitoring of your defibrillator always operational with this 10-lead ECG patient cable, an original replacement (factory reference 33594) designed for the defibrillators with monitor in the RESCUE LIFE 5.7″ and 7″ series. It is the indicated solution for emergency services, hospitalisation, medical transport, consulting rooms and any cardioprotected area equipped with these devices: it extends patient monitoring compared with the 5-lead cable supplied as standard with the device, providing a stable, high-quality signal during care. With specialised technical support from Cahnos to confirm compatibility with your unit before placing the order. For large orders you can request a quote.
2. Technical Explanation
The ECG patient cable is the component that transmits the cardiac electrical signal from the electrodes placed on the patient’s chest to the ECG module of the defibrillator with monitor. On the RESCUE LIFE platform, the ECG module is designed for monitoring (not for diagnostics) and allows up to 12 leads: the device includes as standard a 5-lead patient cable (for I, II, III, aVL, aVR and aVF), while this optional 10-lead cable enables monitoring of up to 12 leads and simultaneous display of up to 12 ECG channels on the high-resolution screen. When the cable is connected to the device, automatic signal switching takes place, so monitoring is completed in any operating mode of the device (manual, AED or advisory), within basic life support (BLS) and advanced life support (ALS) protocols. This reusable accessory must be purchased together with the device (references 33590 or 33591); it is recommended to periodically check the condition of the connectors and the cable insulation.
3. Technical Specifications
Main features of this accessory:
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 33594 |
| Product type | 10-lead ECG patient cable |
| Compatible equipment | Defibrillator with monitor RESCUE LIFE 5.7″ and 7″ |
| Acquisition | Must be purchased together with the device (refs. 33590 or 33591) |
| Monitoring | Up to 12 ECG leads (monitoring module, not diagnostics) |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
Product data
| Sales unit | 1 pc |
|---|---|
| Device type | Medical device |
| Device class | I |
| CND | Z12050380 |
| EAN | 8023279335941 |
4. Equivalences and Cross-References
This cable corresponds to factory reference 33594 and is intended exclusively for the Rescue Life platform. According to the manufacturer’s catalogue, it must be purchased together with the device, in its RESCUE LIFE 5.7″ (ref. 33590) or RESCUE LIFE 7″ (ref. 33591) versions. The device includes a 5-lead patient cable as standard; this 10-lead reference is the manufacturer’s own option for extending monitoring to 12 leads, so it does not replace the standard cable but complements it within the same ecosystem. No verified equivalents of this cable with references from other manufacturers have been identified in reliable sources, since the connector and signal management are proprietary to the Rescue Life platform; any comparison must be previously validated with the technical department of Cahnos. As a similar reference within the Cahnos catalogue, the universal 10-lead ECG patient cable (GM33328) and the GM54001 family of 10-lead ECG patient cables can be consulted, although they are not interchangeable with this model because the connector and target device differ.
5. Selection tips and variants of interest
Confirm the exact model of your device (RESCUE LIFE 5.7″ or RESCUE LIFE 7″) and check the ECG socket on the device before placing the order; our technical team can confirm the connector fit and compatibility with your unit and serial number. Remember that, according to the manufacturer, this cable must be purchased together with the device (refs. 33590 or 33591). If your facility usually works with the included 5-lead cable, this 10-lead reference is the way to extend the patient monitoring possibilities on the same device, without modifying the software configuration. As this is a reusable accessory, it is recommended to have a spare unit per device, periodically check connectors and insulation, and follow the manufacturer’s instructions for use and maintenance. For hospital facilities, mixed fleets or tenders, contact the technical-commercial department of Cahnos to obtain a formalised quote adapted to your needs.