Description
1. Introduction
Complete the paediatric configuration of your defibrillator with these compatible paediatric electrodes, specifically designed for Cardiac Science Powerheart AED and GE Responder AED / AED Pro defibrillators. Intended for schools, nurseries, paediatric practices, emergency services, ambulances and any heart-safe location with children, they ensure rapid and safe care for the smallest patients while keeping your equipment always operational.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency ECG monitoring. For paediatric care, the corresponding paediatric electrodes must always be used, as applying adult energy to a child’s myocardium can be harmful.
According to international cardiopulmonary resuscitation (CPR) guidelines, paediatric treatment is indicated up to 8 years of age, which corresponds to approximately 25 kg of body weight according to standard growth curves. The pads are placed following the anatomical diagrams on the packaging and are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the wrapper.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Product type | Compatible disposable paediatric electrodes (single-use) |
| Indicated population | Up to 8 years or approximately 25 kg according to standard growth curves (CPR guidelines) |
| Manufacturer | GIMA |
| Device type | Medical device (Medical device) |
| Device class | II B |
| Composition | Latex-free |
| Origin | Made in Italy |
| Packaging | Multilingual packaging: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU |
| Regulatory compliance | Compliant with applicable international regulations (same conformity as compatible adult electrodes) |
Compatible equipment
| Brand | Models |
|---|---|
| Cardiac Science | Powerheart AED 9200 series; Powerheart G3 AED 9300 series (G3, G3 Plus, G3 Pro) |
| GE | Responder AED; AED Pro |
Available references
| Reference | Model | Sales unit |
|---|---|---|
| GM33604 | see also 55002 | kit of 2 units |
| GM55002 | COMPATIBLE PAEDIATRIC PADS for defibrillator Cardiac Science, GE | 5 pairs |
4. Equivalences and Cross-References
These paediatric electrodes (GM33604 / GM55002) are consumables compatible with Cardiac Science Powerheart and GE Responder AED / AED Pro defibrillators, not original factory spare parts. The documented original references for these same devices in regulatory databases and operator manuals are Cardiac Science 9730-002 (Powerheart Pediatric Pads, with energy attenuator at ~50 J, verified in GUDID/FDA) and, under GE numbering, 2019199-003 (Pediatric Attenuated Defibrillation Electrode Pads for the GE Responder AED Pro, also verified in GUDID).
There is no equivalence table validated by the device manufacturer that authorises the interchange of pads between brands: the connector, energy management and analysis algorithm are proprietary. Any comparison should be understood as comparable by category and not interchangeable 1:1. Always verify the connector fit with your device before clinical use and consult the technical-commercial department at Cahnos for volume orders or tenders.
5. Selection tips and variants of interest
- Confirm the device model: this pair of electrodes corresponds to the Cardiac Science Powerheart AED 9200, Powerheart G3 9300 (G3, G3 Plus, G3 Pro) and GE Responder AED / AED Pro families. It is not valid for devices with a different connector.
- Paediatric configuration: in centres with children, always keep a pair of paediatric electrodes next to the defibrillator and periodically verify that the device is operational with the pads within their expiry date.
- Compare the sales unit: reference GM33604 is supplied as a kit of 2 units (1 pair) and GM55002 as a box of 5 pairs, ideal for defibrillator fleets or centralised replacement.
- Adult version: for adult patients with the same devices, the compatible version from the same family is available (refs. GM33580 / GM55026).
- Limited-energy variants: as a comparable reference by category (not interchangeable 1:1), the Cahnos catalogue includes limited-energy paediatric electrodes 200 J → 50 J for these same devices (refs. F7957PL and F7957WPL).
- Storage: do not use expired electrodes or those with damaged packaging; check the printed expiry date and rotate stock by expiry (FIFO).