We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Standard adult defibrillator electrode pair with internal cable (pre-connected) – Replacement compatible with Schiller FRED EasyPort, FRED PA-1, Argus Pro LifeCare 1 and 2, Cardiovit AT-101 Easy and Defigard Touch 7 · Ref. F7967

27,25 €

Standard adult defibrillator electrode pair with internal cable (Ref. F7967), single-use replacement consumable compatible with Schiller defibrillators and monitors FRED EasyPort, FRED PA-1, Argus Pro LifeCare 1 and 2, Cardiovit AT-101 Easy and Defigard Touch 7. Self-adhesive multifunction pads for adult patients (over 8 years or over 25 kg) with low-impedance conductive gel, metal foil and 1 mm medical foam backing; they withstand up to 50 shocks at 360 J and allow ECG monitoring for up to 24 h. Their pre-connected configuration plugs directly into the equipment socket, with no loose cables during resuscitation. Class IIb medical device, latex- and phthalate-free, with an approximate shelf life of 30 months. Sold as a pair (2 units) with immediate dispatch; always check the connector fit and packaging expiry before clinical use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7967

Description

1. Commercial Introduction

Keep your Schiller defibrillator or defibrillator monitor from the family always operational with this pair of standard adult defibrillator electrodes with internal cable (Cahnos reference F7967). It is the replacement consumable indicated for the resuscitation of adult patients with the FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy and Defigard Touch 7 equipment.

Its configuration with integrated internal cable (pre-connected) provides a direct and stable connection to the equipment’s electrode socket: no loose cables during the procedure and with the connector protected until the moment of assistance. It is sold as a pair (2 units) in individual heat-sealed packaging and is ready to be integrated into the cardiopulmonary resuscitation protocols of emergency services, ambulances, hospitals, health centres, companies and any heart-safe space equipped with Schiller. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency electrocardiogram monitoring. This pair is indicated for adult patients (over 8 years of age or weighing more than 25 kg) and connects via its integrated internal cable to the safety anti-shock connector of the aforementioned Schiller equipment.

The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal foil distributes the current uniformly and the 1 mm thick medical foam backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), following the anatomical diagrams printed on the packaging and without the two pads coming into contact with each other. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the sachet.

3. Technical Specifications

3.1 Product identification

Reference Cahnos (SKU) F7967
Product type Pair of standard adult defibrillator electrodes, multifunction, with internal cable (pre-connected)
Compatible equipment brand Schiller – FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy, Defigard Touch 7
Presentation Price per pair (2 units); 1 pair in heat-sealed packaging; 10 pairs per box in the adult series

3.2 Technical features

Target population Adult (older than 8 years / more than 25 kg)
Cable configuration Integrated internal cable (pre-connected, direct connection to the equipment’s electrode socket)
Total surface (per electrode) 148 cm² (standard adult series)
Active surface (per electrode) 95 cm² (standard adult series)
Adhesive ring width 1 cm
Supported shocks Up to 50 shocks (50 to 360 J)
Functions Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Connection type Safety anti-shock connector, with internal cable
Use Single-use, disposable, non-sterile; latex-free and phthalate-free
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10
Shelf life Approx. 30 months from the date of production; expiry indicated on the packaging
Storage Dry place, between +5 °C and +35 °C; operation between 0 °C and +50 °C

3.3 Compatible equipment

Equipment brand Compatible models
Schiller FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy, Defigard Touch 7

Technical note: the values for active surface (95 cm²), total area (148 cm²), shocks (50–360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable in this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.

4. Equivalences and Cross-References

Reference F7967 is the Cahnos distribution code for this standard adult electrode with internal cable for the Schiller FRED EasyPort / FRED PA-1 / Argus Pro / Cardiovit AT-101 Easy / Defigard Touch 7 platform; it is not an official reference of the equipment manufacturer. The connector, analysis algorithm and energy management are proprietary to each defibrillator, so equivalences with other references are considered comparable at category level and not interchangeable 1:1. The original factory replacement from Schiller in its pre-connected version is identified by codes 2.155065 and 0-21-00-40, consistently verified at authorised distributors of original Schiller spare parts.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Schiller (original equipment replacement) Pre-connected adult electrodes FRED EasyPort / FRED PA-1 / Argus Pro LifeCare / Defigard Touch 7 2.155065 (also 0-21-00-40) Comparable by category (not interchangeable 1:1) Original factory replacement in pre-connected version (integrated cable) for the same equipment family, documented in authorised distribution of original Schiller spare parts; it comes with an RFID label in the variant for FRED PA-1. Verify connector and batch technical data sheet before replacement.
Schiller (original equipment replacement) Non-pre-connected adult electrodes (version with external cable, equivalent to the F7967W variant) 2.155061 Comparable by category (not interchangeable 1:1) Same equipment family but with cable and connector inside the sachet (not pre-connected); it does not match the internal cable configuration of this reference. Code confirmed in authorised distribution; for contrast reference only.
ZOLL Medical Stat-Padz® II – adult multifunction electrodes (AED Plus / AED Pro) 8900-0801-01 Comparable by category (not interchangeable 1:1) Factory original pre-connected for ZOLL AEDs; polymer conductive gel and proprietary ZOLL connector. Code confirmed in ZOLL technical documentation and GUDID/FDA. Not suitable for Schiller equipment due to proprietary connector and algorithm.

There is no equivalence table validated by the manufacturer that authorises the replacement of original Schiller electrodes with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and IFU; consult the Cahnos technical department before use in tendering.

5. Selection tips and variants of interest

Confirm the equipment model: verify that your defibrillator is a Schiller FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy or Defigard Touch 7 and that the internal cable connector fits correctly into the electrode socket before clinical use; if in doubt, contact the Cahnos technical department stating the model and serial number of your equipment.

Do not confuse versions: this pair is for adult patients (over 8 years or over 25 kg). For the paediatric population of the same family use reference F7967P (internal cable) or F7967PW (external cable); if your workflow requires leaving the connector accessible without opening the pouch, the adult variant with external cable is F7967W, with the original Schiller replacement 2.155061.

Internal cable versus other configurations: the configuration with integrated internal cable provides a direct connection with no loose cables during resuscitation; if you prefer the radiotransparent version for imaging procedures or the external cable series, consult our technical department for references from the same connector family (F7756 for Schiller radiotransparent platforms).

Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or those with a damaged pouch, as the gel may lose conductivity.

Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method). For volume orders or tenders, contact the technical-commercial department of Cahnos stating the exact model and serial number of your defibrillator.

Additional information

Manufacturer reference

2.155065 / 0-21-00-40 (original Schiller replacement, pre-connected; confirm with batch data sheet)

Compatible equipment brand

Schiller

Compatibility

FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy, Defigard Touch 7

Product type

Pair of standard adult defibrillator electrodes, multifunction, with internal cable (pre-connected)

Patient type

Adult (older than 8 years / more than 25 kg)

Cable configuration

Integrated internal cable (pre-connected)

Total surface per electrode

148 cm²

Active surface per electrode

95 cm²

Adhesive ring width

1 cm

Supported shocks

Up to 50 shocks (50–360 J)

Functions

Defibrillation, synchronized cardioversion and ECG monitoring

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector, with internal cable

Use

Single-use, disposable, non-sterile

Latex-free and phthalate-free

Yes

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Shelf life

Approx. 30 months from production; expiry date on the packaging

Storage

Dry place, between +5 °C and +35 °C

Presentation

Pair (2 units); 1 pair in heat-sealed packaging; 10 pairs per box (adult series)

Target population

Adult (>8 years / >25 kg)

ECG monitoring

Up to 24 h

Operating temperature

Between 0 °C and +50 °C

Reviews

There are no reviews yet.

Be the first to review “Standard adult defibrillator electrode pair with internal cable (pre-connected) – Replacement compatible with Schiller FRED EasyPort, FRED PA-1, Argus Pro LifeCare 1 and 2, Cardiovit AT-101 Easy and Defigard Touch 7 · Ref. F7967”

Your email address will not be published. Required fields are marked *