Adult radiolucent defibrillator electrode with internal cable (pair) – Compatible replacement for Nihon Kohden Cardiolife TEC, Welch Allyn AED/PIC, Artema CardioAid, Dräger Cardiolog 2000 and MRL – Ref. F7755

34,75 €

Pair of adult radiolucent defibrillator electrodes with internal cable (Ref. F7755), multi-brand replacement that covers with a single reference the installed bases of Nihon Kohden Cardiolife TEC (cables JC-755V and K342A/JC-855V), Welch Allyn (AED-10, AED-20 and PIC-30/40/50), Artema Innomed and Artema S&W (CardioAid), Dräger (Cardiolog 2000) and MRL (LITE and Life Quest). Disposable multifunction electrodes for defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring, with low-impedance adhesive gel, metal foil and a safety anti-shock connector. Their radiolucent construction allows artefact-free imaging on X-ray and CT. Immediate dispatch and specialised technical support from Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7755

Description

1. Introduction

Keep your defibrillator always operational with this pair of adult radiotransparent defibrillator electrodes with internal cable (Ref. Cahnos F7755). Designed as a multi-brand replacement for equipment from the Nihon Kohden Cardiolife TEC, Welch Allyn AED/PIC, Artema Innomed and Artema S&W CardioAid, Dräger Cardiolog 2000 and MRL families, it allows the consumables stock of emergency departments, ICUs, ambulances, health centres and cardioprotected spaces to be simplified with a single reference.

Its internal cable configuration (connector and cable integrated inside the bag) protects the connection system until the moment of use and leaves the patient’s thorax visible for radiological imaging without interference. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical Explanation

These pads are single-use disposable multifunction electrodes: they perform external defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the discharge energy; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the thorax.

Being radiotransparent, the electrode and its cable do not generate artefacts in fluoroscopy, tomography or intraoperative monitoring, allowing the healthcare team to assess the rib cage, pacemaker or vascular access without removing the pads. The safety anti-shock connector allows direct connection to compatible equipment. Its use is strictly single-patient: after resuscitation they must be disposed of and replaced, always respecting the expiry date of the packaging.

3. Technical specifications and compatibility

3.1 Technical specifications

Parameter Specification
Reference Cahnos (SKU) F7755
Patient type Adult (older than 8 years / more than 25 kg)
Electrode type Disposable multifunction: defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring
Radiotransparency Yes (electrode and cable), suitable for imaging procedures
Cable configuration Internal cable integrated into the package; direct connection after opening
Total surface per electrode 136 cm²
Active surface per electrode 94 cm²
Adhesive ring width 0.7 cm
Supported shocks Up to 50 shocks at 360 J
ECG monitoring Max. 24 h
Composition Medical foam (1 mm), low-impedance conductive adhesive gel, metal foil and safety anti-shock connector
Use Single patient only, do not reuse
Latex / phthalates Free from latex and phthalates
Regulatory classification Medical device Class IIb (Directive 93/42/EEC)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10
Operating temperature 0 °C to +50 °C
Storage temperature +5 °C to +35 °C (dry place, not in direct sunlight)
Shelf life 30 months from the date of manufacture
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box

3.2 Compatibility with defibrillators

Equipment brand Compatible models Cable / required accessories
Nihon Kohden Cardiolife TEC-5500 Series, TEC-5600 Series, TEC-7600 Series, TEC-7700 Series, TEC-2202, TEC-2203, TEC-7531, TEC-8251 and TEC-8300 Series Cable JC-755V (TEC-5500, TEC-7600, TEC-7700, TEC-2202, TEC-2203, TEC-7531, TEC-8251) · Cable K342A / JC-855V (TEC-5600, TEC-8300)
Welch Allyn AED-10, AED-20, PIC-30, PIC-40 and PIC-50 Paediatric adapter Welch Allyn 002173-U (AED-10) · Paediatric adapter Welch Allyn 002174-U (AED-20)
Artema Innomed CardioAid 360B, CardioAid 200B, CardioAid 200, CardioAid 100, CardioAid XL+ and CardioAid XL Safety anti-shock connector
Artema S&W CardioAid LS, CardioAid MC and CardioAid MC+ Safety anti-shock connector
Dräger Cardiolog 2000 Safety anti-shock connector
MRL LITE and Life Quest Safety anti-shock connector

Note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your equipment before clinical use.

4. Equivalences and Cross-References

Reference F7755 corresponds to a pair of adult radiotransparent multifunction electrodes with internal cable for the Nihon Kohden, Welch Allyn, Artema Innomed, Artema S&W, Dräger and MRL families. This is a consumable compatible with the cited defibrillators, not an original spare part certified by each equipment manufacturer: the connector and energy management of each defibrillator are proprietary. After verifying official manufacturer catalogues and regulatory databases, the following cross-references with code confirmed in public sources are identified.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nihon Kohden Disposable adult/child/infant pad (original equipment) P-740K Comparable by category (not interchangeable 1:1) Code confirmed in official documentation of Nihon Kohden and authorised distribution: factory original with 1.5 m cable; covers AED-2100, AED-3100 and TEC-5500/5600/7600/7700/8300 series. Proprietary connector, gel and labelling; radiotransparent nature has not been verified and the cable is inside the packaging. Verify connector fit before replacement.
Nihon Kohden Disposable AED adult/child pad (original TEC-8300K / TEC-8342) P-711 (order code H329) Comparable by category (not interchangeable 1:1) Code confirmed on the official website of Nihon Kohden Europe and authorised distribution: original with 1.5 m cable, aimed at the Cardiolife AED and TEC-8300 families (including TEC-8342). Proprietary connector; radiotransparency not verified. Verify compatibility before replacement.
Welch Allyn (AED line) Original adult pad for AED-10 and AED-20 001855-U Comparable by category (not interchangeable 1:1) Original reference confirmed in authorised technical distribution: adult pair with cable inside the packaging for AED-10 and AED-20, without verified radiotransparent nature. It shares the AED-10/20 platform but is not interchangeable 1:1 due to cable and connector configuration.
HeartSync (Nissha Medical Technologies) Defibrillation pads compatible with Nihon Kohden TEC-5500/5600/7600/7700/8300 T100AC-NIHONKOHDEN (ref. 6600265H) Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: radiolucent (radiotransparent) adult pair, total surface area 371 cm², connector comparable to the original Nihon Kohden and cable integrated inside the packaging (2 m). Presentation and areas different from this reference; verify connector and cable (JC-755V / JC-855V depending on series).

For the Dräger Cardiolog 2000, MRL LITE / Life Quest and Artema CardioAid equipment, no verifiable original electrode code has been found in public sources, so the equivalences for those families remain pending confirmation with the manufacturer. The original Welch Allyn paediatric adapters 002173-U (AED-10) and 002174-U (AED-20) appear consistently in the manufacturer’s documentation and are the accessories required for paediatric use on those devices.

There is no manufacturer-validated equivalence table authorising the replacement of original electrodes with third-party pads: the connector and energy management of each defibrillator are proprietary. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator; consult the technical department of Cahnos before using in tenders.

5. Selection tips and variants of interest

  • Identify the model and cable of your equipment: in Nihon Kohden, the TEC-5600 and TEC-8300 series use the K342A / JC-855V cable, while the rest of the series in the table use the JC-755V. Always check the connector fit before clinical use.
  • Paediatric use on Welch Allyn AED-10 / AED-20: requires the original energy-reducing adapter 002173-U or 002174-U (2 units); without this accessory, therapy must not be applied to paediatric patients. For patients under 8 years of age or weighing less than 25 kg, the paediatric version of the same family is available (F7755P).
  • Choose radiotransparent when imaging tests are anticipated: if the patient may require X-ray, fluoroscopy or CT during care, this version avoids artefacts without removing the electrode. If imaging is not required, the standard version with internal cable (F7955), at lower cost, may be considered.
  • Variants in the same Cahnos family: radiolucent version with external cable (F7755W) if you prefer to leave the pair pre-connected and ready for emergency use; paediatric radiolucent version with internal cable (F7755P); standard non-radiolucent versions (F7955 internal cable and F7955W external cable). Other platforms in the radiolucent internal-cable category (F7750 Philips, F7751 Zoll, F7752 Physio-Control, F7753 Agilent HP, F7754 Schiller, F7756 Schiller) are not interchangeable with one another due to their proprietary connector.
  • Storage and expiry: store in a dry place between +5 °C and +35 °C and observe the expiry date stated on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO). For volume orders or tenders, contact the Cahnos technical department, stating the exact model and serial number of your equipment.

Additional information

Patient type

Adult (>8 years / >25 kg)

Electrode type

Disposable multifunction: defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring

Radiolucent

Yes (electrode and cable)

Cable type

Internal cable integrated into the package

Total surface per electrode

136 cm²

Active surface per electrode

94 cm²

Adhesive ring width

0.7 cm

Supported shocks

Up to 50 shocks at 360 J

ECG monitoring

Up to 24 hours

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector

Compatibility

Nihon Kohden Cardiolife TEC (JC-755V / K342A-JC-855V), Welch Allyn AED-10/20 and PIC-30/40/50, Artema Innomed and Artema S&W CardioAid, Dräger Cardiolog 2000, MRL LITE and Life Quest

Required accessories

Paediatric adapters Welch Allyn 002173-U (AED-10) and 002174-U (AED-20)

Presentation

Pair of electrodes in individual heat-sealed packaging

Sales format

10 pairs per box

Regulatory classification

Medical device class IIb (Directive 93/42/EEC)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Use

Single-use, disposable

Latex-free and phthalate-free

Yes

Operating temperature

0 °C to +50 °C

Storage

Dry place, +5 °C to +35 °C

Shelf life

30 months from the date of manufacture