Keep your Nihon Kohden Cardiolife defibrillator always operational with these compatible electrodes (ref. GM33575): a kit of 2 disposable pads for adult patients (>8 years / 25 kg) BSI certified, with excellent skin adhesion and adequate gel thickness for optimal shock transmission. The set includes a pair of electrodes, cable and connector, is latex-free and offers a maximum shelf life of 30 months from production. Compatible with the TEC 2202, 2203, 5500, 7531, 7600, 7700 and JC-765V series, as well as TEC 5600 and 8300 with cable JC855V. Class IIb medical device manufactured in Italy. For large orders you can request a quote.

Sales unit: kit de 2
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33575

Description

1. Commercial Introduction

Keep your Nihon Kohden Cardiolife defibrillator always ready for emergencies with these compatible, disposable adult defibrillation electrodes (ref. GM33575), the ideal replacement consumable for emergency services, critical care units, ambulances and cardio-protected spaces equipped with equipment from the Cardiolife TEC family. With a single reference it covers the main defibrillators of this platform, simplifying the stock of resuscitation consumables. BSI certified for adult patients, they are supplied in a kit of 2 units: contact our technical-commercial team. For large orders you can request a quote.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and allows emergency electrocardiographic monitoring. This adult pair is indicated for patients over 8 years of age or weighing more than 25 kg and is manufactured with a conductive adhesive gel that ensures excellent adhesion to the skin and adequate thickness, guaranteeing low interface impedance and optimal energy transmission during assistance. The set includes a pair of electrodes, the connection cable and the specific connector for the Nihon Kohden platform. They are single-use and disposable: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging. The recommended placement is anterolateral (sternum-apex), following the anatomical diagrams on the multilingual envelope.

3. Technical specifications and tables

3.1 Product data

Manufacturer GIMA
Sales unit Kit of 2 units (kit of 2 pcs)
Device type Medical device (Medical device)
Device class II B
CND C020401
GMDN 45806

3.2 Available references

Reference Model Sales unit
GM33575 Compatible electrodes for Nihon Kohden defibrillator (see also 55037) Kit of 2 units
GM55037 Manufacturer’s associated multi-pair presentation (see 55037) Multipair

3.3 Main features

Parameter Specification
Indicated population Adults: patients >8 years (25 kg)
Use Disposable, single-use
Kit contents Pair of electrodes, cable and connector
Adhesion and gel Excellent adhesion and adequate gel thickness
Material Latex-free
Maximum shelf life 30 months from the date of production
Certifications BSI; ANSI/AAMI: DF-80; IEC/EN: 60601-1, 60601-2-4; ISO: 10993-1
Conformity Directive 93/42/EEC and amendments (Class IIb)
Packaging Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU
Manufacture Made in Italy

3.4 Compatibility with defibrillators

Equipment brand Compatible models Cable / connection
Nihon Kohden Cardiolife TEC 2202, 2203, 5500, 7531, 7600, 7700 and JC-765V —
Nihon Kohden Cardiolife TEC 5600 and 8300 Cable JC855V

4. Equivalences and Cross-References

This kit is a compatible consumable with the aforementioned Nihon Kohden defibrillators, not an original replacement certified by the equipment manufacturer: the connector, the analysis algorithm and the energy management are proprietary to each platform. Within the catalogue, reference GM33575 (kit of 2 units) is associated with the multi-pair presentation 55037 of the same electrode. At category level, the original factory electrodes Nihon Kohden for the TEC families are references P-740K and P-711 (order code H329), comparable by category but not interchangeable 1:1.

Manufacturer / Brand Family / Model Code / SKU Equivalence level
(associated catalogue) Same electrode in multi-pair presentation 55037 Associated presentation of the same product
Nihon Kohden (original equipment) Disposable adult/child/infant pad for AED and TEC series P-740K Comparable by category (not interchangeable 1:1)
Nihon Kohden (original equipment) Disposable adult/child/infant AED electrodes P-711 (code H329) Comparable by category (not interchangeable 1:1)

There is no equivalence table validated by the manufacturer that authorises the replacement of original electrodes with third-party pads: always verify the exact model of the equipment and the fit of the connector before clinical use. Consult the technical department of Cahnos before considering any substitution in tenders.

5. Selection tips and variants of interest

Confirm the equipment model: check on the defibrillator plate that your model is among the compatible ones (Cardiolife TEC 2202, 2203, 5500, 7531, 7600, 7700, JC-765V, and TEC 5600 / 8300 with cable JC855V) and that the connector fits correctly into the electrode socket before clinical use.

Presentation and volume: reference GM33575 is supplied in a kit of 2 units for individual replacement; if your centre manages several devices or high turnover, consult the associated multi-pair presentation (reference 55037).

Range of compatible electrodes: each platform requires its specific reference due to proprietary connector: Nihon Kohden (GM33575), Agilent-Philips (GM33576), Agilent/Hewlett-Packard/Laerdal (GM33577), Defibtech Lifeline (GM33578) and Drager/Innomed/S&W/Welch Allyn (GM33579). They are not interchangeable with each other.

Expiry and storage: the maximum shelf life is 30 months from the production date. Store in a dry place, at moderate temperature, and respect the expiry date printed on the packaging; the conductive gel may lose conductivity if exceeded. As it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock by expiry date (FIFO method). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact models of your equipment.

Additional information

Sales unit

Kit of 2 units (kit of 2 pcs)

Device type

Medical device (Medical device)

CND code

C020401

GMDN code

45806

Indicated population

Adults: patients >8 years (25 kg)

Use

Disposable, single-use

Contents

Pair of electrodes, cable and connector

Material

Latex-free

Shelf life

30 months from the date of production

Certifications

BSI; ANSI/AAMI: DF-80; IEC/EN: 60601-1, 60601-2-4; ISO: 10993-1

Regulatory standard

Directive 93/42/EEC and amendments (Class IIb)

Packaging

Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU

Compatibility

Nihon Kohden Cardiolife TEC 2202, 2203, 5500, 7531, 7600, 7700, JC-765V; TEC 5600 and 8300 with cable JC855V

Manufacture

Made in Italy

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Compatible and Disposable Adult Defibrillator Electrodes for Nihon Kohden Cardiolife TEC – Kit of 2 units with Cable and Connector (Ref. GM33575)”

Your email address will not be published. Required fields are marked *