Description
1. Commercial Introduction
Keep your defibrillator-monitor always ready to act with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7953W). It is the ideal replacement and replenishment consumable for emergency services, critical care units (ICU), ambulances, hospitals and cardioprotected spaces equipped with the Philips / Agilent Hewlett-Packard and Laerdal Medical families: with a single reference it covers the most widespread defibrillator fleets of these brands (CodeMaster 100, XE, XL, XL+ and HeartStart 4000, as well as XL/XLT and MRx), simplifying the resuscitation stock.
Its configuration with external cable (lead-out) leaves the connector accessible without opening the sealed pouch: at the critical moment you only need to remove the protector and place the pads according to the anatomical diagrams on the packaging, minimising preparation time. Price per pair (2 units), individual heat-sealed packaging, immediate dispatch from Cahnos and specialised technical support to verify compatibility by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock, enables synchronised cardioversion and monitors the emergency electrocardiogram. This pair is indicated for adult patients (over 8 years old or weighing more than 25 kg) and connects to the electrode socket of compatible devices via a safety anti-shock connector.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm thick medical foam (FOAM) backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), following the diagrams on the packaging. They are single-use: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the pouch.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7953W |
| Product type | Pair of standard multifunction adult defibrillator electrodes with external cable (lead-out) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | External cable (preconnectable / lead-out), approximate length of 120 cm in the series |
| Radiotransparency | No (standard version; for artefact-free imaging there is the radiotransparent series of the family) |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Functions | External defibrillation, synchronised cardioversion and ECG monitoring |
| ECG monitoring | Up to 24 hours |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector or clip (depending on model), with external cable |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Presentation | Price per pair (2 units); 1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series) |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
3.1 Compatibility with defibrillators
| Equipment model | Factory reference | Observations |
|---|---|---|
| CodeMaster 100 | M2475B | Direct connection |
| CodeMaster XE | M1724A | Direct connection |
| CodeMaster XL | M1723A / M1723B | Direct connection |
| CodeMaster XL+ | M1722A / M1722B | Direct connection |
| HeartStart 4000 | M5500B | Energy in manual adjustment |
| HeartStream / HeartStart XL | M4735A | Requires hands-free electrode cable M3508A |
| HeartStream / HeartStart XLT | M3500B | Requires hands-free electrode cable M3508A |
| HeartStart MRx | M3535A / M3536A | Requires cable M3508A; do not use in fully automatic mode |
| Laerdal AED Trainer 2 | — | Direct connection (training) |
Note: with HeartStart 4000, XL/XLT and MRx do not use in fully automatic defibrillators; the energy is adjusted manually. Always verify the correct insertion of the connector into the device socket before clinical use.
4. Equivalences and Cross-References
The reference F7953W is the Cahnos distribution code for this standard adult electrode with external cable (EuroDefiPads series) for the cited Philips / Agilent Hewlett-Packard and Laerdal Medical defibrillator families; it is not an original certified reference from the device manufacturer: the connector, analysis algorithm and energy management are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID/FDA), the following cross-references with confirmed codes in public sources are identified. In no case does an official equivalence table validated by the manufacturer exist; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips Healthcare | Adult Multifunction Pads, IEC barrel connector (platform original) | M3502A (alternative code 989803106931) | Comparable by category (not interchangeable 1:1) | Factory original for the CodeMaster 100 (M2475B), XE (M1724A), XL/XL+ (M1723A/B, M1722A/B) and HeartStart 4000 (M5500B) families via M3507A cable. Code confirmed in authorised technical distribution and device regulatory database (FDA authorisation K991871). Not radiotransparent; verify connector, surface and cable before replacement. |
| Leonhard Lang | Skintact® Easibeat – adult multifunction electrodes Philips CodeMaster | DF26N | Comparable by category (not interchangeable 1:1) | Adult electrode with connector compatible with CodeMaster XE, XL, XL+ and 100; 1 pair per pouch and 10 pairs per box; overlapping gel technology. Code confirmed in Leonhard Lang’s technical catalogue and in authorised distribution; with M3507A adapter cable it also covers HeartStart MRx, XL, XL+ and Efficia DFM100. Verify connector fit before replacement. |
| Cardinal Health (Covidien) | Medi-Trace Cadence adult RTS (radiotransparent) | 22661R (preconnected: 22661PC) | Comparable by category (not interchangeable 1:1) | Radiotransparent adult pair with barrel connector compatible with the Philips / Agilent-HP family (CodeMaster, HeartStream/HeartStart XL, XL+, MRx and HeartStart 4000); silver/silver chloride gradient technology and 10 pairs per box. Code confirmed in GUDID (DI 20884527022370) and manufacturer’s catalogue. Differs in radiotransparency, cable and geometry; verify connector and surfaces. |
| Nissha Medical Technologies (HeartSync) | T100AC-PHILIPS – radiolucent adult pair compatible with Philips | 6600091H | Comparable by category (not interchangeable 1:1) | Radiolucent (radiotransparent) adult pair for HeartStart MRx, HeartStart XL, Intrepid, FR2+ and ForeRunner; 36-month service life and long conductors. Code confirmed in the manufacturer’s official catalogue. Requires verifying connector and compatibility with the exact device model. |
There is no equivalence table validated by the manufacturer (Philips / Agilent-HP) that authorises the replacement of the original electrodes with third-party pads: the connector, the analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the equipment connector, the energy range, the target population and the expiry date of the packaging. Consult the technical department at Cahnos before use in tenders.
5. Selection tips and variants of interest
- Confirm the model and the equipment connector: check the exact model on the defibrillator nameplate (CodeMaster 100/XE/XL/XL+, HeartStart 4000, XL/XLT, MRx) and the required therapy cable (M3507A / M3508A on models that require it) before storing the replacement.
- Do not confuse versions: this pair is for adult patients (over 8 years / more than 25 kg). For the paediatric population with the same equipment, use the paediatric reference with external cable (F7953PW) or with internal cable (F7953P).
- External cable vs. internal cable: this variant leaves the connector accessible so the equipment can be pre-connected and ready in seconds (ideal in ambulances and heart-safe spaces); if you prefer a placement without loose cables, the internal-cable version of the same platform is available (F7953).
- Standard vs. radiolucent electrode: this reference is not radiolucent. If the patient may require X-ray, fluoroscopy or CT during care, consider the radiolucent series of the same family (F7753 with internal cable or F7753W with external cable), which avoids image artefacts without removing the electrode.
- Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. As a single-use consumable, maintain a minimum stock per defibrillator unit and rotate stock according to expiry (FIFO method).
For volume orders or tenders, contact the technical-commercial department at Cahnos, quoting the exact model and serial number of your defibrillator.