Adult defibrillator radiolucent electrode with internal cable (pair) — Compatible replacement for CU Medical Systems i-PAD NF 1200 and CMOS Drake Life 400 Futura — Ref. F7759

34,75 €

Pair of adult defibrillator radiolucent electrodes with internal cable (Ref. F7759), compatible replacement for CU Medical Systems i-PAD NF 1200 and CMOS Drake Life 400 Futura defibrillators, as well as equipment from the Saver One line. Disposable multifunction electrodes for defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring, with low-impedance conductive adhesive gel, active surface area of 94 cm² per electrode and support for up to 50 shocks at 360 J. Their radiolucent construction (electrode and cable) allows the pads to remain in place during X-ray or CT scan without image artefacts. Latex and phthalate free, class IIb medical device; immediate dispatch from Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7759

Description

1. Commercial Introduction

Keep your defibrillator always operational with this pair of radiotransparent adult defibrillator electrodes with internal cable (Ref. F7759), a highly reliable consumable compatible with the equipment CU Medical Systems i-PAD NF 1200 and CMOS Drake Life 400 Futura, as well as with the defibrillators of the Saver One line. Designed for emergency services, ICU, ambulances, health centres, operating theatres and cardioprotected points, it simplifies stock management with a single reference per platform. Its integrated internal cable configuration maintains a clean and stable connection throughout resuscitation, and its radiotransparent construction allows imaging control without removing the patches. Available with immediate dispatch from Cahnos and specialised technical assistance for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock, enables synchronised cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency ECG monitoring. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the internal metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest.

Being radiotransparent —electrode and cable—, they do not generate artefacts in radioscopy, tomography or intraoperative control, allowing the healthcare team to assess the rib cage, pacemaker or vascular accesses without removing the patches. The recommended placement in adults is anterolateral (sternum-apex), according to the anatomical diagrams on the packaging. They are single-use: after resuscitation they must be discarded and replaced, always respecting the expiry date printed on the pouch.

3. Technical specifications and compatibility

3.1 Technical specifications

Main characteristics of the series of radiotransparent adult electrodes (internal/external cable) to which this reference belongs:

Parameter Specification
Reference Cahnos (SKU) F7759
Product type Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable
Patient type Adult (older than 8 years / more than 25 kg)
Radiotransparency Yes (electrode and cable), suitable for imaging procedures
Cable configuration Integrated internal cable (leads-in)
Functions External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring
Total surface per electrode 136 cm²
Active surface per electrode 94 cm²
Adhesive ring width 0.7 cm
Supported shocks 50 to 360 J
ECG monitoring Max. 24 h
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (1 mm thick)
Connection type Anti-shock safety connector or clip (depending on the equipment model)
Use Single-use, disposable; latex-free and phthalate-free
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box
Shelf life Approx. 30 months from production date (expiry on packaging)
Operating temperature 0 °C to +50 °C
Storage Dry place, between +5 °C and +35 °C
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Technical note: the values for active surface (94 cm²), total area (136 cm²), shocks (50–360 J) and adhesive ring (0.7 cm) correspond to the series of radiotransparent adult electrodes of this product family; confirm with the technical data sheet of the supplied batch and the device manual before use in tendering.

3.2 Compatibility with defibrillators

Equipment brand Compatible models Observations
CU Medical Systems i-PAD NF 1200 (semi-automatic) · i-PAD NF 1201 (automatic, verify) Proprietary connector for the NF 1200 platform
CMOS Drake AED Life 400 Futura (Futura model) Proprietary connector; the device detects authenticity and validity of the pads
Saver One line (Cahnos) Models of the Saver One platform Verify model and connector fit before ordering

Note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your device before clinical use.

4. Equivalences and Cross-References

Reference F7759 is a consumable compatible with the cited defibrillators, not an original spare part certified by each equipment manufacturer: the connector, authenticity/validity detection and energy management are proprietary. After verifying official manufacturer catalogues and equipment manuals, the following cross-references with code confirmed in public sources are identified. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
CU Medical Systems (equipment manufacturer) i-PAD SAVER NF1200 / NF1201 Adult Electrode Pads (original equipment) CUA0903PF Comparable by category (not interchangeable 1:1) Code confirmed in the official CU Medical Systems catalogue and in authorised distribution: original adult pair for the i-PAD NF 1200 and NF 1201 devices, with proprietary connector; the radiotransparent nature of the original has not been verified. Verify expiry and connector fit before replacement.
CMOS Drake (equipment manufacturer) Disposable adhesive adult shock pads – Life 400 Futura (original equipment) LT49131 · LT72471 Comparable by category (not interchangeable 1:1) Original references documented in Appendix A (accessories list) of the official user manual of the AED Life 400 Futura; proprietary connector and authenticity/validity detection system of the pads in the device. Verify expiry and connector fit before replacement.

There is no equivalence table validated by CU Medical Systems or CMOS Drake that authorises the replacement of original electrodes with third-party pads: the connector, originality/validity detection and energy management of each defibrillator are proprietary. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator; consult the technical department of Cahnos before using in a tender.

5. Selection tips and variants of interest

Confirm the model and connector of your equipment: this pair corresponds to the CU Medical Systems i-PAD NF 1200 (and NF 1201, verify) and CMOS Drake Life 400 Futura defibrillators, as well as the Saver One line. Check the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention.

Choose the variant according to your workflow: the internal cable of this model provides a clean and robust connection during resuscitation; if radiolucency is not required, consider the standard version of the same platform (F7959), at a lower cost. If you attend to paediatric patients, paediatric references F7959P (CMOS Drake Futura) and F7958P (CU Medical Systems) are available, with automatic energy reduction when connecting the paediatric pair.

Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. As it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO). For volume orders or tenders, contact the technical department of Cahnos indicating the exact model and serial number of your equipment.

Additional information

Reference

F7759

Product type

Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable

Patient type

Adult (>8 years / >25 kg)

Radiotransparency

Yes (electrode and cable), for artefact-free imaging

Cable configuration

Internal cable (connector and cable integrated in the sealed packaging)

Compatibility

CU Medical Systems i-PAD NF 1200 / NF 1201 · CMOS Drake Futura (Life 400 Futura) · Amoul Ambulanc (Shenzhen) TECH.

Functions

Defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring

Total surface

136 cm² per electrode

Active surface

94 cm² per electrode

Adhesive ring width

0.7 cm

Supported shocks

50 to 360 J

ECG monitoring

Max. 24 h

Material

Medical foam (1 mm), low-impedance conductive adhesive gel, metal foil and safety anti-shock connector

Use

Single-use, disposable; latex-free and phthalate-free

Latex, phthalates

Free from latex and phthalates

Regulatory classification

Medical device Class IIb (Directive 93/42/EEC; MDR 2017/745)

Reference standards

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Operating temperature

0 °C to +50 °C

Storage temperature

+5 °C to +35 °C

Shelf life

Approx. 30 months from production date (expiry on packaging)

Presentation

1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box

Compatible brand

CU Medical Systems (i-PAD NF 1200), CMOS Drake (Life 400 Futura) and Saver One line

Compatible models

i-PAD NF 1200 (semi-automatic); i-PAD NF 1201 (verify); AED Life 400 Futura; Saver One platform

Population

Adults over 8 years or weighing more than 25 kg

Cable type

Integrated internal (leads-in)

Connector

Anti-shock safety connector or clip (depending on the equipment model)

Total surface per electrode

136 cm²

Active surface per electrode

94 cm²

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

Medical foam (1 mm thick)

Classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

Storage

Dry place, +5 °C to +35 °C; operation 0 °C to +50 °C