ECG electrode for Holter and long-term monitoring TNT Ø 55 mm – Solid gel, Ag/AgCl sensor and central snap fastener – Box of 600 units (Ref. 0590014)

2,41 €

Disposable ECG electrode of non-woven fabric (TNT) with conductive solid gel, Ag/AgCl sensor and central snap-type press stud, in circular format of Ø 55 mm. Designed for long-term monitoring and Holter studies of 24-72 h in adult patients: medical-grade adhesive, low impedance and maximum breathability for a stable signal and firm fixation throughout the recording. Compliant with ANSI/AAMI EC 12, latex-free, hypoallergenic and single-use. Presentation in a bag of 30 units; minimum sale unit: box of 600 units.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0590014

Description

1. Introduction

The TNT electrode for prolonged monitoring, Ø 55 mm (reference Cahnos 0590014, model NM 55 TNI from the Top Trace Monitoring line) is the reference consumable for Holter studies and prolonged cardiac monitoring in adult patients. Its highly breathable non-woven fabric backing, combined with a low-impedance solid conductive gel, ensures a stable electrocardiographic signal during 24 to 72-hour recordings, with excellent adhesion and a comfort that patients appreciate on a daily basis. Supplied in bags of 30 units with a minimum box of 600 units, it is the high-turnover solution for cardiology departments, intensive care units, primary care practices and purchasing groups that need a reliable, hypoallergenic electrode with excellent cost per procedure.

2. Technical Explanation

The surface ECG electrode acts as an interface between the patient’s skin and the monitor or Holter recorder: it captures the heart’s electrical activity and transmits it with the least possible distortion. Recording quality depends on three key factors: adhesion (the electrode must remain fixed throughout the test), conductivity (low skin-electrode contact impedance) and breathability, which is essential in prolonged use.

The NM 55 TNI electrode uses a non-woven fabric (TNT) backing of fibres coated with non-sensitising acrylic copolymer, which allows the skin to breathe and adapts to body movements, reducing the risk of detachment and irritation during long-term recordings. The solid conductive gel is presented in a polymerised hydrogel formulation: it maintains its aqueous content without dripping or shifting with sweat, offering low impedance and stable signal capture throughout the recording. The Ag/AgCl sensor and central snap-type press stud facilitate connection to patient cables on most Holter systems and bedside monitors on the market. It is a single-use, latex-free, hypoallergenic, non-irritating and non-sensitising product that meets and exceeds the performance requirements of the ANSI/AAMI EC 12 standard.

3. Technical Specifications

Main features of the NM 55 TNI electrode (reference Cahnos 0590014), according to the Top Trace line technical documentation:

Parameter Specification
Reference Cahnos (SKU) 0590014
Model / family NM 55 TNI (Top Trace Monitoring line)
Type Conventional disposable electrode for Holter and long-term monitoring
Backing material Breathable non-woven fabric (TNT) with medical-grade adhesive (non-sensitising acrylic copolymer)
Gel Solid conductive gel (polymerised hydrogel, non-irritating and non-sensitising)
Diameter Ø 55 mm (circular format)
Sensor material Ag/AgCl
Connection type Central snap-type press stud
Application Holter and prolonged monitoring (24-72 h); resting ECG
Presentation Bag of 30 units
Minimum sales unit Box of 600 units
Use Single-use, disposable, non-sterile; latex-free

Electrical data and standards (typical values from the Top Trace line technical documentation):

Parameter Value
DC offset voltage ≤ 0.12 mV (ANSI/AAMI EC 12 limit: ≤ 100 mV)
AC impedance at 10 Hz ≤ 60 Ω (ANSI/AAMI EC 12 limit: ≤ 2,000 Ω)
Biocompatibility ISO 10993-1 (cytotoxicity, irritation and sensitisation passed)
Regulatory compliance ANSI/AAMI EC 12:2000/(R)2005; Class I medical device with CE marking (Directive 93/42/EEC)
Expiry 36 months in sealed packaging
Storage Dry, cool place (5-32 °C), in the sealed packaging until use

Note: the electrical values are taken from the Top Trace line technical documentation; confirm the exact values with the supplied batch sheet for use in tenders.

4. Equivalences and Cross-References

Reference 0590014 is the Cahnos distribution code for this adult Holter and prolonged monitoring electrode; there is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with third-party brands. The following references share the same category (disposable ECG electrode with solid gel and snap-type connection for prolonged monitoring in adults) and have a confirmed code in the manufacturer’s official catalogue, GUDID regulatory database or authorised technical distribution. They are classified as comparable by category, not interchangeable 1:1: each field (backing, gel, diameter and connector) must be verified before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
FIAB (Italy) F2080 – disposable non-woven electrode with solid gel, Ø 55 mm, snap connection F2080 (technical distribution Gima ref. 33327) Comparable by category (not interchangeable 1:1) Code confirmed in the official FIAB catalogue and authorised technical distribution (Gima, Almamedical, Securlab): non-woven fabric (TNT) with solid gel, Ø 55 mm, round shape, Ag/AgCl sensor, snap connection and indicated for rest, long-term monitoring, stress and Holter ECG. It is the closest equivalent as it matches in backing, gel type, diameter, shape and connection; the presentation differs (bags of 50 units and box of 1,200 units). Check the snap fit with the patient cable before replacing.
Ambu (Denmark) WhiteSensor CMM/1 – breathable fabric backing electrode with solid gel for long-term monitoring CMM-00-S (CMM/1-00-S/30; GUDID 05707480036158) Comparable by category (not interchangeable 1:1) Code confirmed on the official Ambu website, GUDID and authorised distribution: breathable non-woven fabric backing, highly conductive solid gel, central snap-type connector, presentation of 30 units/bag and 1,500 units/box, indicated for Holter, event recording and long-term monitoring. Difference: diameter of 50 mm (according to Ambu’s official data sheet) versus the Ø 55 mm of this reference. Validate contact surface and cable fit before replacing.
3M / Solventum Red Dot Monitoring Electrode – foam with solid adhesive gel (sticky gel) 2560 (also V2560-5; GUDID 00707387789305) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and the official Solventum/3M catalogue: foam electrode with solid adhesive gel, snap connection, Ag/AgCl sensor and validated prolonged use (up to 5 days). Difference: foam backing versus TNT and rectangular geometry of 4 × 3.5 cm versus the circular Ø 55 mm format; check contact surface and adhesion before replacement.
Cardinal Health Kendall Medi-Trace 530 Series – foam for Holter and diaphoretic monitoring 31013926 (series 530) Comparable by category (not interchangeable 1:1) Code confirmed in the official Cardinal Health catalogue and authorised distribution: foam electrode with conductive adhesive hydrogel (solid gel), snap connection, ANSI/AAMI EC 12 compliance and indicated for Holter and monitoring with a suggested use time of less than 72 h. Difference: foam backing and drop-shaped geometry of approx. 44 mm versus the circular TNT of Ø 55 mm.

There is no equivalence table validated by the manufacturer that authorises 1:1 substitution between brands of monitoring electrodes: the type of backing (TNT, paper or foam), the type of gel (solid or liquid), the diameter and the position of the connector condition adhesion and signal quality. Any substitution must be validated against the technical data sheet and instructions for use of the electrode manufacturer and the monitoring system, checking one by one diameter, backing, gel and connector; consult the technical department of Cahnos before use in tenders. As homologous reference families on the market, solid gel electrodes on fabric backing from Skintact (Leonhard Lang) or other long-term monitoring series from technical suppliers may also be cited, always pending code confirmation against an official source.

5. Selection tips and variants of interest

Choose according to the duration of the recording: this TNT electrode with solid gel of Ø 55 mm is the optimal option for Holter studies and prolonged monitoring of 24-72 h thanks to its breathability, firm fixation and stable signal even with moderate sweating. If your department needs greater resistance to sweat in stress tests, consider the foam alternatives with solid gel from the same family, such as the ECG and stress test electrode ST 50 RFI (ref. 0590028); if you prefer the same solid gel on medical paper backing of Ø 55 mm, you have the T 601 S model (ref. 16003), and for a microporous TNT format of Ø 50 mm, ref. 15778.

Check the connector of your patient cable: this electrode features a central snap-type press stud, the most common standard in Holter cables and bedside monitors. If your fleet uses crocodile clips or banana connectors, consult the range of electrodes with tab and the connection adapters from Cahnos before selecting. Variants of the same diameter in the catalogue: non-woven fabric electrode with liquid gel of Ø 55 mm (ref. 15552, model W 601 L) and foam electrode with liquid gel of Ø 55 mm for monitoring and stress (ref. 11310 or 14709); they share clinical indication but differ in backing and gel type, so they must be adapted to the department’s protocol.

Skin preparation: to optimise contact impedance and avoid repeats due to poor signal, proper prior skin cleaning with the preparation gels from the Cahnos catalogue is recommended, especially in patients with oily skin or cream residues. Storage and replenishment: store sealed bags in a dry, cool place (5-32 °C), rotate stock on a FIFO basis and respect the expiry date indicated on the packaging (36 months); the solid gel may lose conductivity if the packaging is opened or deteriorates. For volume orders, complete supplies or tenders, contact the technical-commercial department of Cahnos indicating the model of your Holter fleet and the type of connector.

Additional information

Model / family

NM 55 TNI (Top Trace Monitoring line)

Product type

Disposable ECG electrode for Holter and long-term monitoring

Backing material

Breathable non-woven fabric (TNT) with medical-grade adhesive (non-sensitising acrylic copolymer)

Gel

Solid conductive gel (polymerised hydrogel, non-irritating and non-sensitising)

Sensor material

Ag/AgCl

Diameter

Ø 55 mm (circular format)

Connection

Central snap-type press stud

Application

Holter and prolonged monitoring (24-72 h); resting ECG

Presentation

Bag of 30 units

Minimum sales unit

Box of 600 units

Use

Single-use, disposable, non-sterile; latex-free

Latex-free

Yes (hypoallergenic, non-irritating, non-sensitising)

Electrical performance

DC offset voltage ≤ 0.12 mV; AC impedance at 10 Hz ≤ 60 Ω (typical values)

Regulatory standard

ANSI/AAMI EC 12:2000/(R)2005; biocompatibility ISO 10993-1; Class I medical device with CE marking (Directive 93/42/EEC)

Shelf life

36 months in sealed packaging

Storage

Dry, cool place (5-32 °C), in the sealed packaging until use