We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable paediatric ECG electrode of circular foam Ø 30 mm with solid Ag/AgCl gel – Ref. NM 30 RFI – Box of 900 units (SKU 590016)

2,91 €

Disposable paediatric ECG electrode of circular foam Ø 30 mm with high-conductivity solid gel and Ag/AgCl sensor, reference NM 30 RFI (SKU 590016). Its central press stud (snap) makes it compatible with standard patient cables for cardiac monitoring and electrocardiogram in paediatrics, critical patients and difficult adhesion conditions. Foam coated with medical-grade acrylic copolymer, hypoallergenic, latex-free and single-use; compliant with ANSI/AAMI EC 12:2000/(R)2005 and Directive 93/42/EEC (Class I, CE marking). Presentation in aluminium bag of 30 units; minimum sales unit in box of 900 units (5,400 units/master carton).

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
590016

Description

1. Commercial Introduction

The NM 30 RFI ECG electrode (SKU 590016) is the reference disposable consumable for cardiac monitoring and electrocardiographic recording in paediatric patients and in critically ill patients who require a secure and stable contact even under difficult adhesion conditions. Its circular foam format of Ø 30 mm, its highly conductive solid gel and its silver/silver chloride (Ag/AgCl) sensor guarantee a clean trace, low impedance and without the drawbacks of liquid gels: no residue, no mess and firm adhesion from the very first moment. It is the cost-optimised solution for paediatrics departments, ICUs, emergency departments, cardiology consultations, medical transport and any high-turnover monitoring point. Supplied in an aluminium pouch of 30 units, with a minimum sales unit of a box of 900 units.

2. Technical explanation of the electrode

The electrode acts as an electrical interface between the patient’s skin and the monitor or electrocardiograph. The foam support coated with an aggressive medical-grade acrylic copolymer adhesive firmly fixes the patch to the chest, while the central column of solid conductive gel —a polymerised hydrogel with aqueous content— maintains moisture and conductivity throughout the recording, without irritating the skin: it is non-irritating, non-sensitising and non-cytotoxic. The Ag/AgCl sensor offers a stable contact potential and very low polarisation, reducing motion artefacts and ensuring a reliable electrocardiographic signal. Its central snap connection (snap/pressure type) allows direct coupling to patient cables with button terminal, the most common standard in ECG cables with forceps or alligator clips for limbs. It is a single-use, hypoallergenic, latex-free and non-sterile product, indicated for standard monitoring and short-duration electrocardiograms.

3. Technical Specifications

Characteristic Specification
Type Conventional disposable electrode for paediatric ECG monitoring
Reference / model NM 30 RFI · SKU Cahnos 590016 (0590016)
Support material Foam (medical foam) coated with aggressive acrylic copolymer, non-sensitising
Shape Circular
Diameter Ø 30 mm
Gel Conductive solid gel (polymerised hydrogel, non-irritant, non-sensitising, non-cytotoxic)
Sensor Ag/AgCl (silver/silver chloride)
Connection Central pressure snap (snap type), centred gel column
Application Paediatric ECG, standard monitoring and critical patients
Composition Hypoallergenic, latex-free
Electrical performance Meets and exceeds ANSI/AAMI EC 12:2000/(R)2005; low contact impedance
Use Single-use (disposable), non-sterile
Presentation Aluminium sachets of 30 units
Minimum sales unit Box of 900 units (5,400 units/master carton)
Expiry 36 months with sealed packaging
Regulatory classification Class I medical device with CE marking (Directive 93/42/EEC, D.L. 46/97)

Verified electrical performance (according to the family technical data sheet):

Parameter (ANSI/AAMI EC 12) Value
DC offset voltage 0.12 mV
AC impedance at 10 Hz 60 Ω
DC offset 5 s after capacitor discharge 6.5 mV
AC impedance after defibrillation 46 Ω
Recovery slope (30 s interval) 0.0 mV/s

4. Equivalences and Cross-References

The NM 30 RFI reference is the line code of the electrode marketed by Cahnos; there is no official equivalence table published by the manufacturer that cross-references this code with third-party codes. After verifying official catalogues and manufacturer websites, the following homologous references with confirmed codes have been identified. All of them are classified as comparable by category (not 1:1 interchangeable): before any substitution, the diameter, support material, gel type, sensor, connector and commercial presentation must be checked one by one.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Lessa (AB Medica Group, Spain) Snap electrode Ø 30 mm, foam, solid conductive adhesive gel 9983012 (official cat.) Comparable by category (not interchangeable 1:1) They match Ø 30 mm, foam support, solid conductive gel, snap connector (clasp) and paediatric use for short-duration resting ECG. The presentation differs: box of 600 units (20 sachets of 30) versus 900 units. Verified on the manufacturer’s official website.
Dormo® (Telic Group, Spain) DORMO® SX-30 ECG Electrode Ø 30 mm, solid gel, Ag/AgCl sensor SX-30 (SKU TEM01) Comparable by category (not interchangeable 1:1) They match Ø 30 mm, foam support (flexible PE), solid gel of water-soluble acrylic polymer, Ag/AgCl sensor, latex-free, class I (EU Regulation 2017/745) and ANSI/AAMI EC12 requirements. Differences: allows wear time of up to 24 h, pouch of 100 units and box of 2,500 units, with adult/paediatric/neonatal application. Verified on the manufacturer’s website.
Medke Disposable Infant Foam Electrode, Solid Gel, White BA-103 Comparable by category (not interchangeable 1:1) They match Ø 30 mm, foam support, solid gel, paediatric/infant use, latex-free and snap or forceps connection. The commercial presentation differs (pouches of 100 units). Code verified on the manufacturer’s official website and in its public CE/ISO 13485 data sheet.
Leonhard Lang (Skintact®) F-301 Monitoring ECG Electrode, 30 mm, Paediatric, Solid Gel F-301 Comparable by category (not interchangeable 1:1) They match Ø 30 mm, foam backing, solid gel (Aqua-Tac) and paediatric use. The presentation differs (30 units/sachet, box of 1,500 units) and the backing (foam/microporous depending on version). Verified on the manufacturer’s website and authorized technical distribution.

There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. Any substitution between brands must be validated against the technical data sheet of the manufacturer issuing the code, checking one by one diameter, backing material, gel type (solid or liquid), sensor, connector type (snap versus 4 mm banana) and regulatory classification.

5. Selection tips and variants of interest

Check the connector on your patient cable: this electrode has a central press stud (snap type). If your cable ends in a 4 mm banana, consider the rectangular foam electrode of 28 x 44 mm with banana connector (NM 2844 FBI, SKU 590025) or use a snap-to-banana adapter; if you use crocodile clips, the range of tab electrodes is the appropriate alternative. Choose the diameter according to the patient: the circular format of Ø 30 mm is the reference size for paediatrics and critical patients; for very low birth weight neonates, the pre-wired radiolucent family of Ø 22 mm is available (RT 22 LWF, SKU 15079) and for adults or stress testing, the circular electrode of Ø 50 mm with high-adhesion solid gel (ST 50 RFI, SKU 0590028) or its version with liquid gel (ST 50 RLI, SKU 0590024). For recordings with possible imaging control, consider the radiolucent electrodes from the same family (SKU 0590022). Keep the bags sealed in a dry place, rotate stock on a FIFO basis and respect the 36-month expiry: the solid gel may lose conductivity if exposed to air. As it is a single-use consumable, maintain a minimum stock per monitoring station. For supplies, tenders or bids, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connector on the patient cable.

Additional information

Product type

Conventional disposable electrode for monitoring and paediatric ECG

Model reference

NM 30 RFI

Backing material

Foam (medical foam) with aggressive non-sensitising acrylic copolymer adhesive

Shape

Circular

Diameter

Ø 30 mm

Gel

Solid gel (polymerised hydrogel, non-irritant, non-sensitising, non-cytotoxic)

Sensor

Ag/AgCl (silver/silver chloride)

Connection

Central pressure snap (snap type)

Application

Paediatric ECG, standard monitoring and critical patients

Use

Single-use, disposable, hypoallergenic, latex-free

Presentation

Aluminium sachets of 30 units

Minimum sales unit

Box of 900 units (5,400 units/master carton)

Shelf life

36 months with sealed packaging

Electrical performance

ANSI/AAMI EC 12:2000/(R)2005: AC impedance 10 Hz ≤60 Ω; DC offset after discharge ≤6.5 mV; AC impedance after defibrillation ≤46 Ω

Regulatory standard

Directive 93/42/EEC (D.L. 46/97); class I medical device with CE marking

Model / family

NM 30 RFI

Type

Conventional disposable electrode for monitoring and ECG

Material

Foam (medical foam)

Sensor material

Ag/AgCl (silver/silver chloride)

Adhesive

Medical-grade acrylic copolymer, aggressive and non-sensitising

Main packaging

5,400 units per master carton

Regulatory classification

Class I medical device with CE marking (Directive 93/42/EEC, D.L. 46/97)

Storage

Dry place, between 5 °C and 32 °C

Registration

C.N.D. C020501

Latex

Latex-free