Disposable ECG electrode for Holter and stress test ST 50 RFI – Foam with solid gel Ø 50 mm – Top Trace line – Bag of 30 units and box of 600 units (SKU 0590028)

2,68 €

Electrode ST 50 RFI from the Top Trace line for Holter monitoring and stress test: foam (medical foam) with high-adhesion solid gel, in circular format Ø 50 mm and snap-type press stud compatible with standard patient cables of monitors and ergometers. Offers stable signal, low contact impedance and firm attachment even with intense sweating, making it ideal for prolonged recordings and demanding physical tests. Presentation in bag of 30 units; minimum sales unit: box of 600 units. Single-use consumable, latex-free and compliant with ANSI/AAMI EC 12 performance requirements, designed for cardiology departments, ICUs and high-turnover diagnostic units.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0590028

Description

1. Commercial Introduction

The ST 50 RFI electrode (reference Cahnos 0590028) is a disposable ECG electrode from the Top Trace line, made of medical foam with solid conductive gel, in a circular format of Ø 50 mm. It is specifically designed for ambulatory Holter monitoring and stress testing or ergometry in adult patients, where the demand for adhesion and signal stability is highest. Its high adhesion, highly conductive solid gel and high-turnover format (bag of 30 units, with a minimum box of 600) make it the reference solution for cardiology departments, ergometry units, sports medicine, hospitals and purchasing centres that need a reliable consumable that is comfortable for the patient and offers excellent cost per procedure.

2. Technical Explanation

A surface ECG electrode acts as an interface between the patient’s skin and the monitor or recorder: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study, even with sweating), conductivity (low skin-electrode contact impedance) and stability against movement.

The foam backing (medical foam) is flexible, lightweight and moisture-resistant: it protects the gel and sensor, adapts to the contour of the chest and maintains its integrity during prolonged Holter recordings and intensive stress tests. The solid gel, formulated as a polymerised hydrogel in a central column, does not drip or shift with sweat, maintains its water content and ensures rapid signal acquisition with low impedance, reducing motion artefacts. The assembly is hypoallergenic, non-irritating, non-sensitising and latex-free, meeting and exceeding the performance requirements of the voluntary standard ANSI/AAMI EC 12 for disposable ECG electrodes. It is a single-use product for clinical and hospital use, which must be discarded after each patient.

3. Technical Specifications

Main features of the ST 50 RFI electrode (reference Cahnos 0590028), according to the technical documentation of the Top Trace line:

Parameter Specification
Reference Cahnos (SKU) 0590028
Model / family ST 50 RFI (Top Trace line)
Type Disposable ECG electrode for Holter and stress testing
Backing material Medical foam with medical-grade adhesive
Gel High-adhesion solid conductive gel (polymerised hydrogel)
Diameter Ø 50 mm (circular format)
Connection type Snap-type press stud (check fit with the patient cable of the monitor)
Application Holter monitoring, stress testing and ergometry in adults
Advantages High adhesion, highly conductive gel, stable signal in difficult conditions
Presentation Bag of 30 units
Minimum sales unit Box of 600 units
Use Clinical and hospital; single-use, disposable, non-sterile
Composition Latex-free; non-irritating, non-sensitising
Reference standards ANSI/AAMI EC 12 (performance requirements for disposable ECG electrodes); medical device with CE marking
Storage Store in a cool, dry place in sealed packaging until use

Note: sensor data (Ag/AgCl) and electrical values of the batch are provided with the supplied batch certificate; confirm with the manufacturer’s documentation before use in tendering.

4. Equivalences and Cross-References

Reference 0590028 is the Cahnos distribution code for this adult foam electrode with solid gel; it is a standard consumable with snap connector, not an official reference of the monitoring system manufacturer. There is no equivalence table validated by the manufacturer that authorises 1:1 cross-referencing with third-party brands. The following references share the category (disposable foam ECG electrode with snap connection for Holter, monitoring and stress testing in adults) and have a confirmed code based on GUDID regulatory database, official manufacturer catalogue or authorised technical distribution. They are classified as comparable by category, not interchangeable 1:1: each field (diameter, gel type, geometry and connector position) must be verified before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
3M / Solventum Red Dot™ Monitoring Electrode – foam with solid adhesive gel (sticky gel), diaphoretic 2560 (also V2560-5; GUDID 00707387789305) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official catalogue: foam with solid adhesive gel, snap connection and prolonged use validated up to 5 days. Differs in geometry: rectangular format 4 × 3.5 cm vs. circular Ø 50 mm. Verify contact surface and cable fit before replacing.
Cardinal Health Kendall™ Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) 31013926 (series 530) Comparable by category (not interchangeable 1:1) Code confirmed in official catalogue of Cardinal Health and authorised technical distribution: foam with conductive adhesive hydrogel (solid gel), snap connection, indicated for stress, Holter and diaphoretic monitoring with suggested use less than 72 h, compliant with ANSI/AAMI EC 12. Differs: drop shape approx. 44 mm vs. circular format of 50 mm.
Leonhard Lang (Skintact®) F-601 C – monitoring electrode with foam and solid gel F-601C Comparable by category (not interchangeable 1:1) Code confirmed in official catalogue of Leonhard Lang: PE foam, solid gel, Ø 50 mm and snap connector. It is the closest homologous reference as it matches dimensions and gel type (version suitable for imaging); verify batch adhesive, radiolucency and box format before replacement.
Ambu BlueSensor™ R – foam electrode with wet gel (adult) R-00-S / R-00-S/5 (GUDID 05707480022205) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official catalogue of Ambu: foam, Ag/AgCl sensor and offset snap connector, approx. 57 × 48 mm. Key difference: wet gel (highly conductive) vs. solid gel of this reference, and offset connector vs. centred snap. Validate cable fit before replacing.

There is no equivalence table validated by the manufacturer that authorises 1:1 substitution between brands of Holter and stress test electrodes: the type of backing, type of gel (liquid or solid), diameter and connector position affect adhesion and signal quality. Any substitution must be validated against the technical data sheet and instructions for use of the electrode manufacturer and the monitoring system, checking one by one diameter, backing, gel and connector; consult the technical department of Cahnos before using in a tender.

5. Selection tips and variants of interest

Solid gel, the choice for demanding conditions: the solid gel of this reference avoids liquid residues and maintains conductivity even with intense sweating, making it ideal for prolonged Holter and stress tests. If your service prefers even faster signal pickup, the same family offers the version with liquid gel ST 50 RLI Ø 50 mm (ref. 0590024).

Variants within the Cahnos catalogue: if imaging tests (X-ray or MRI) are expected during monitoring, consider the radiolucent solid gel versions RT 50 RFI (ref. 0590022) or F 50 S BLUE (ref. 15843); for stress test in rectangular format, the FS 501 S 45 × 35 mm with solid gel (ref. 11322); for larger adhesive surface, the F 55 L Ø 55 mm with liquid gel (ref. 11310). All share foam and gel technology, but differ in size, geometry and connection type.

Check the connector: ensure that the patient cable of your Holter monitor or ergometer is compatible with snap-type connection before placing the order; if your equipment uses alligator clips or banana connectors, consult the range of tab electrodes and connection adapters from Cahnos.

Preparation and storage: clean and dry the skin before application and avoid creams or oily residues to optimise contact impedance. Keep bags sealed in a cool, dry place, rotate stock on a FIFO basis and respect the expiration date: solid gel can lose conductivity if the packaging is opened or damaged. For volume orders, complete sets or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection.

Additional information

Model / family

ST 50 RFI (Top Trace line)

Product type

Disposable ECG electrode for Holter and stress testing

Backing material

Foam (medical foam) with medical-grade adhesive

Gel

High-adhesion solid conductive gel (polymerised hydrogel)

Diameter

Ø 50 mm

Connection

Centred press stud (snap)

Application

Holter monitoring, stress testing and ergometry in adults

Presentation

Bag of 30 units

Minimum sales unit

Box of 600 units

Main packaging

7,200 units / main carton

Use

Single-use, disposable, non-sterile; clinical and hospital use

Shelf life

36 months in sealed packaging

Regulatory standard

ANSI/AAMI EC 12 (performance requirements); medical device with CE marking

Connector

Snap-type press stud (check fit with monitor cable)

Storage

Store in a cool, dry place in sealed packaging until use

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Disposable ECG electrode for Holter and stress test ST 50 RFI – Foam with solid gel Ø 50 mm – Top Trace line – Bag of 30 units and box of 600 units (SKU 0590028)”

Your email address will not be published. Required fields are marked *