We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable foam ECG electrode with offset snap connection and liquid gel – Ø 50 mm round for adult (Ref. 33309 / FIAB F2017) – Box of 1,000 units

108,00 €

Disposable ECG electrode made of foam (PE-foam) in round format, Ø 50 mm for adult patient, with offset snap-type press stud connector and highly conductive liquid gel. It incorporates a silver/silver chloride (Ag/AgCl) sensor for stable, low-impedance signal acquisition, and is indicated for short- to medium-term monitoring, stress ECG recording (ergometry) and Holter studies. References: Ref. 33309 / FIAB F2017. Presentation: box of 1,000 units (20 bags of 50 units). Class I medical device, single-use, high turnover in cardiology departments, ICUs, ergometry rooms and diagnostic units.

In stock (can be backordered)

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F2017

Description

1. Commercial Introduction

The disposable foam ECG electrode with offset snap connection (reference 33309, code FIAB F2017) is a high-turnover consumable designed for cardiac monitoring in adult patients. Its round format of Ø 50 mm, conductive liquid gel and silver chloride sensor ensure a stable signal from the first seconds of recording, while the offset snap press stud facilitates a firm fit with the patient cable and better anatomical adaptation. It is supplied in a box of 1,000 units (20 bags of 50 units), making it the ideal solution for cardiology departments, ergometry units, sports medicine, ICUs and purchasing centres that need a reliable electrode that is comfortable for the patient and offers excellent cost per procedure.

2. Technical Explanation

A surface ECG electrode acts as an interface between the patient’s skin and the monitor or recorder: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion, conductivity (low skin-electrode contact impedance) and stability against movement.

The polyethylene foam (PE foam) backing is lightweight, flexible and moisture-resistant: it protects the gel and sensor, adapts to the contour of the chest and maintains its integrity during short-term monitoring recordings, stress tests and Holter studies. The conductive liquid gel ensures rapid signal acquisition with low initial impedance, reducing motion artefacts typical of ergometry. All electrodes incorporate a silver chloride (Ag/AgCl) sensor and an offset snap press stud connection, which provides a secure fit with standard patient cables. This is a single-use product for clinical and hospital use, which must be disposed of after each patient and stored in its closed packaging in a cool, dry place.

3. Technical Specifications

Main features of the disposable foam ECG electrode with offset snap connection (reference 33309 / FIAB F2017):

Parameter Specification
Reference (SKU) 33309
FIAB code F2017
Type Disposable surface ECG electrode
Material PE-Foam (polyethylene foam)
Size 50 mm (round format)
Gel Liquid
Connection Off-centre snap press stud
Sensor Silver chloride (Ag/AgCl)
Patient Adult
Application Short- and medium-term monitoring, stress ECG (ergometry) and Holter study
Presentation Box of 1,000 units (20 bags of 50 units)
Sales unit Box of 1,000 units
Use Single-use, disposable

Product data

Manufacturer GIMA
Sales unit Box of 1,000 units
Device type Medical device
Device class I
CND C020501
GMDN 35035
EAN 8054953341224

4. Equivalences and Cross-References

Reference 33309 corresponds to the Cahnos distribution code (SKU GM33309) for this foam electrode with liquid gel and offset snap connector; code F2017 is the manufacturer’s reference from FIAB. There is no equivalence table validated by the manufacturer that authorises a 1:1 cross-reference with third-party brands: substitution must be verified field by field (diameter, gel type, connector position and adhesive) before any change.

By category, the following are identified as comparable (not interchangeable 1:1): foam electrodes with wet gel and offset snap connector such as the Ambu BlueSensor™ R (R-00-S / R-00-S/25), the FS-50 foam electrode with Aqua-Wet™ liquid gel from Leonhard Lang (Skintact®) and the foam electrodes with adhesive gel Red Dot™ from 3M/Solventum (2560, V2560-5). All share application in monitoring and stress testing in adults, but differ in geometry, connector position or gel formulation, so the fit of the patient cable to the monitor fleet must be validated before substituting.

5. Selection tips and variants of interest

Check the connector: this electrode features an offset snap press stud. Confirm that the patient cable of your monitor, ergometer or Holter recorder is compatible with snap connection before placing the order; if your fleet uses crocodile clips or banana connectors, consult the range of tab electrodes and connection adapters from Cahnos.

Variants within the Cahnos catalogue: for liquid gel and Ø 50 mm with centred snap, you have the FS 50 L electrode (ref. 11312, box of 1,200 units) or the high-adhesion ST 50 RLI (ref. 0590024, box of 600 units); for monitoring and resting ECG, the F 50 L (ref. 15492); and for a larger adhesive surface, the F 55 L with Ø 55 mm (ref. 11310). If your department performs prolonged monitoring or recordings with heavy sweating, consider the solid gel versions from the same family, such as the ST 50 RFI (ref. 0590028). All share clinical indication but differ in gel, diameter or connector position: adapt the choice to your department’s protocol and the connection type of your cables.

Preparation and storage: clean and dry the skin before placement and avoid creams or oily residues to optimise contact impedance. Keep the bags closed in a cool, dry place, rotate stock on a FIFO basis and respect the expiry date: the liquid gel may lose conductivity if the packaging is opened or damaged. For volume orders, full allocations or tenders, contact the technical-commercial department of Cahnos, indicating the model of your monitor fleet and the connection type.

Additional information

fiab code

F2017

Product type

Disposable surface ECG electrode

Material

PE-Foam (polyethylene foam)

Measurements

Ø 50 mm (round format)

Gel

Liquid

Connection

Off-centre snap press stud

Sensor

Silver chloride (Ag/AgCl)

Patient

Adult

Application

Short- and medium-term monitoring, stress ECG and Holter

Presentation

Box of 1,000 units (20 bags of 50 units)

Unit of sale

Box of 1,000 units

CND code

C020501

GMDN code

35035

EAN

8054953341224

Use

Single-use, disposable

Presentacion

Box of 1000

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Disposable foam ECG electrode with offset snap connection and liquid gel – Ø 50 mm round for adult (Ref. 33309 / FIAB F2017) – Box of 1,000 units”

Your email address will not be published. Required fields are marked *