Description
1. Commercial Introduction
The Y-type auricle pulse oximeter SpO₂ sensor for adults is the spare and replacement solution for services that monitor oxygen saturation with Philips multiparameter equipment. Compatible with a wide range of monitors from the M and VM series, this sensor restores SpO2 measurement with the quality of the original product, at a cost optimised for B2B supply contracts.
Its placement on the auricle is especially practical in adult patients with damaged nail beds, delicate peripheral perfusion, or in procedures where the finger forceps is not viable. As it is supplied with a multilingual manual (ES, FR, IT and GB), it is a replacement ready to integrate into any hospitalisation, emergency, ICU, resuscitation or medical transport service.
2. Technical explanation
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed of the auricle, and a photodetector quantifies the differential absorption of light according to the degree of blood oxygenation, transmitting the signal to the monitor via the cable connector.
The Y-type design of this sensor adapts to the contour of the earlobe, with a soft clip that ensures optimal contact of the emitters and the photodetector, stability against patient movement and a reliable signal during continuous monitoring. With a cable length of 3.0 m, it offers a comfortable working radius from the bed or chair to the monitor module, and its connection system is prepared for Philips monitors from the M and VM series indicated by the manufacturer.
3. Technical Specifications
Sensor features
| Sensor type | Y-type auricle (ear) pulse oximeter SpO₂ sensor for adults |
|---|---|
| Compatibility | Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8 |
| Cable length | 3.0 m |
| Patient population | Adults (auricle) |
| Reference | 35281 |
| Documentation included | Multilingual manual (GB, FR, IT, ES) |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6900234100603 |
4. Equivalences and Cross-References
Reference 35281 is the management code of Cahnos for this Y-type auricle sensor, indicated as a replacement compatible with Philips monitors M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6 and VM8. We do not have a manufacturer-validated equivalence table that cross-references this reference with a specific original part number from Philips; for any tender or bid, it is recommended to confirm with the technical department the exact OEM code of the installed monitor before placing the order.
The replacement of the SpO2 sensor must always be validated against the specific monitor of the centre, verifying the connector type and the supported pulse oximetry protocol, since functional compatibility does not imply 1:1 interchangeability with sensors of other technologies or from the same manufacturer for other equipment.
5. Selection tips and variants of interest
Always check the exact series and model of the Philips monitor (M3, M4, MP20–MP80 or VM4/VM6/VM8) to confirm connector and SpO2 protocol compatibility before ordering the replacement. The auricle sensor is the recommended option when the finger forceps is not viable or when a comfortable fit is sought during prolonged monitoring in adult patients.
Within the family of sensors for pulse oximeters distributed by Cahnos, you will also find sensors compatible with Nellcor protocol equipment (refs. 18631, 18632, 18633 and 18634, in disposable format per box of 25 units) for those monitor fleets that use that standard. For special B2B conditions by volume, replenishment contracts or tenders, please consult our technical-commercial team.





Reviews