Disposable ECG electrode for stress testing (ergometry) from the Top Trace line, model ST 50 RLI (SKU 0590024): white foam with highly conductive liquid gel, medical-grade acrylic adhesive, Ag/AgCl sensor and centred snap-type press stud. Circular format of Ø 50 mm, latex-free and compliant with the performance requirements of ANSI/AAMI EC 12, designed to maintain a stable signal even with intense sweating and movement during exercise. Presentation in a bag of 30 units; minimum sales unit: box of 600 units (main packaging of 7,200 units). Single-use, non-sterile product, ideal for cardiology departments, ergometry units, sports medicine and high-turnover diagnostic centres.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0590024

Description

1. Product Presentation

The ST 50 RLI electrode (reference Cahnos 0590024) is the reference consumable for stress testing or ergometry in adult patients: a disposable ECG electrode made of foam with conductive liquid gel, in a circular format of Ø 50 mm and a centred snap connector. Its foam backing coated with medical-grade acrylic adhesive ensures firm fixation during intense exercise, while the liquid gel ensures rapid signal acquisition with low impedance from the first seconds of recording. Presented in a bag of 30 units with a minimum box of 600 units, it is the high-turnover solution for cardiology departments, ergometry units, sports medicine, hospitals and purchasing centres that need a reliable electrode, comfortable for the patient and with excellent cost per procedure.

2. Technical explanation

A surface ECG electrode acts as an interface between the patient’s skin and the stress test recorder: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study, even with sweating), conductivity (low skin-electrode contact impedance) and stability against movement.

The foam support (medical foam) is flexible, adapts to the contour of the chest and protects the gel and the sensor under demanding conditions. The liquid gel, formulated with potassium chloride, provides a rapid signal response and low initial impedance, reducing the movement artefacts typical of ergometry. The Ag/AgCl sensor and the centred snap connector (compatible with most snap-type patient cables on the market) complete a hypoallergenic, non-irritating, non-sensitising and latex-free set that meets and exceeds the performance requirements of the voluntary standard ANSI/AAMI EC 12.

3. Technical Specifications

Main characteristics of the ST 50 RLI electrode (reference Cahnos 0590024), according to the manufacturer’s technical data sheet:

Parameter Specification
Reference Cahnos (SKU) 0590024
Model / family ST 50 RLI (Top Trace line)
Type Disposable ECG electrode for stress testing
Backing material White foam with aggressive medical-grade acrylic adhesive
Gel Conductive liquid gel (high conductivity, low impedance)
Sensor material Ag/AgCl
Diameter Ø 50 mm (circular format)
Connection type Centred press stud (snap)
Application Stress testing, ergometry and monitoring under difficult adhesion conditions
Presentation Bag of 30 units
Minimum sales unit Box of 600 units
Main packaging 7,200 units / main carton
Use Single-use, disposable, non-sterile
Composition Latex-free; hypoallergenic, non-irritating, non-sensitising
Storage Dry and cool place (5-32 ºC), closed container
Regulatory standard ANSI/AAMI EC 12 (performance requirements); medical device with CE marking

Note: the electrical values (offset voltage, AC impedance at 10 Hz, etc.) are provided with the supplied batch certificate; confirm them with the batch documentation before use in tendering.

4. Equivalences and Cross-References

Reference 0590024 is the Cahnos distribution code for this adult foam electrode with liquid gel; there is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with third-party brands. The following references share the same category (disposable foam ECG electrode with wet/liquid gel and button connection for stress testing and monitoring in adults) and have a code confirmed in the GUDID regulatory database, official manufacturer catalogue or authorised technical distribution. They are classified as comparable by category, not interchangeable 1:1: a field-by-field check (diameter, gel type, connector position and adhesive) must be performed before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Leonhard Lang (Skintact®) FS-50 – exercise stress test electrode with foam and Aqua-Wet™ liquid gel FS-50 (official catalogue; 30 units/bag, 1,200 units/box) Comparable by category (not interchangeable 1:1) Code confirmed in the official Leonhard Lang catalogue: PE foam, Aqua-Wet™ liquid gel, snap connector, Ø 50 mm, reinforced adhesive and indicated for stress testing, emergency care and echocardiography. It is the closest homologous reference as it matches in backing, gel type, diameter and indication; verify the connector position and adhesive of the specific batch before substituting.
Ambu (Denmark) BlueSensor R – foam electrode with wet gel (adult) R-00-S / R-00-S/25 (GUDID 05707480022205) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and the official Ambu catalogue: foam, highly conductive wet gel, Ag/AgCl sensor and offset snap connector; suitable for stress testing and monitoring. Dimensions 57 × 48 mm (48 mm effective): smaller diameter and offset connector compared to the centred snap of this reference; validate the cable fit before substituting.
3M / Solventum Red Dot™ Monitoring Electrode – foam with adhesive gel (sticky gel) 2560 (also V2560-5; GUDID DI 00707387789305) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official catalogue: foam with solid adhesive gel, snap connection and prolonged use validated up to 5 days. Differences: solid gel compared to the liquid gel of this reference and rectangular geometry of 4 × 3.5 cm compared to the circular format of 50 mm; verify contact surface and adhesion before substitution.
Cardinal Health (Kendall™) Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) 31013926 (series 530) Comparable by category (not interchangeable 1:1) Code confirmed in the official Cardinal Health catalogue and authorised distribution: foam with conductive adhesive hydrogel (solid gel), snap connection, indicated for stress, Holter and diaphoretic monitoring (suggested use less than 72 h), compliant with ANSI/AAMI EC 12. Differences: solid gel and drop shape of approx. 44 mm compared to the circular liquid gel of 50 mm.
Vermed (Nissha Medical) Performance Plus™ Foam Wet Gel Electrode – stress testing and Holter A10005-60 (60 units/bag) Comparable by category (not interchangeable 1:1) Code confirmed in authorised technical distribution: teardrop-shaped foam of 38 mm (1.5 in.), wet gel with high chloride content, Ag/AgCl sensor, aggressive hypoallergenic adhesive and snap connection; intended for stress testing and Holter. Differs: geometry and diameter compared with the 50 mm circular format.

There is no equivalence table validated by the manufacturer that authorises 1:1 substitution between brands of stress test electrodes: the type of backing, the type of gel (liquid or solid), the diameter and the position of the connector condition adhesion and signal quality. Any substitution must be validated against the technical data sheet and instructions for use of the electrode manufacturer and the monitoring system, checking one by one diameter, backing, gel and connector; consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

Liquid gel vs. solid gel: the liquid gel of this reference provides very fast signal acquisition and low initial impedance, ideal for stress testing. If your department performs prolonged monitoring (Holter) or recordings with extreme sweating, consider the versions of the same family with solid gel, such as the ST 50 RFI electrode of Ø 50 mm (ref. 0590028) or the radiotransparent RT 50 RFI (ref. 0590022).

Diameter and format: this Ø 50 mm electrode offers an excellent balance between adhesive surface and comfort. If you prefer the same backing and gel in a box of 120 units, you have the FS 50 L electrode of Ø 50 mm (ref. 11312); for a larger adhesive surface, the F 55 L of Ø 55 mm with liquid gel (ref. 11310) is an alternative from the same line.

Check the connector: this electrode features a centred snap-type press stud. Check that the patient cable of your ergometer or monitor is compatible with snap connection before placing the order; if your fleet uses crocodile clips or banana connectors, consult the range of electrodes with tab and the connection adapters from Cahnos.

Preparation and storage: clean and dry the skin before application and avoid creams or oily residues to optimise contact impedance. Keep the bags closed in a dry, cool place (5-32 ºC), rotate stock on a FIFO basis and respect the expiry date: the liquid gel may lose conductivity if the packaging is opened or deteriorates. As this is a high-turnover single-use consumable, maintain a minimum stock per monitoring station. For volume orders, complete supplies or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection.

Additional information

Model / family

ST 50 RLI (Top Trace line)

Product type

Disposable ECG electrode for stress testing

Backing material

White foam with aggressive medical-grade acrylic adhesive

Gel

Conductive liquid gel with high conductivity and low impedance

Sensor material

Ag/AgCl

Diameter

Ø 50 mm (circular format)

Connector

Centred press stud (snap)

Application

Stress testing, ergometry and monitoring under difficult adhesion conditions

Presentation

Bag of 30 units

Minimum sales unit

Box of 600 units

Main packaging

7,200 units / main carton

Use

Single-use, disposable, non-sterile

Latex-free

Yes (hypoallergenic, non-irritating, non-sensitising)

Regulatory standard

ANSI/AAMI EC 12 (performance requirements); medical device with CE marking

Intended use

Stress testing, ergometry and monitoring under difficult adhesion conditions

Storage

Dry and cool place (5-32 ºC), closed container

Reviews

There are no reviews yet.

Be the first to review “Disposable ECG electrode for stress testing ST 50 RLI – Foam with liquid gel Ø 50 mm with centred snap Ag/AgCl – Bag of 30 units, box of 600 (SKU 0590024)”

Your email address will not be published. Required fields are marked *