Description
1. Commercial Introduction
The FS 501 S electrode (reference Cahnos 11322) is a disposable surface ECG consumable, made of foam (medical foam) with solid conductive gel in a 45 x 35 mm format. It is specifically designed for stress testing and ergometry, where the demands on adhesion and signal stability are at their highest during physical exercise. Its central snap button and aggressive medical-grade adhesive ensure firm fixation even with intense sweating, with precise signal transmission from the first seconds of recording. It is supplied in a bag of 50 units, with a minimum sales unit of a box of 2,000 units: it is the high-turnover solution for cardiology departments, ergometry rooms, sports medicine units and purchasing centres that need a reliable electrode, comfortable for the patient and with excellent cost per procedure.
2. Technical Explanation
A surface ECG electrode acts as an interface between the patient’s skin and the monitor or recorder of the stress test: it captures the heart’s electrical activity and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study, even with sweating), conductivity (low skin-electrode contact impedance) and stability against movement.
The foam backing is impermeable to liquids and very flexible: it protects the gel and the sensor, adapts to the contour of the chest and withstands the demanding conditions of a stress test. The solid conductive gel, in a central column, offers a fast signal response with low impedance and eliminates the mess of liquid gels, maintaining its aqueous content in a polymerised hydrogel formulation: non-irritating, non-sensitising and non-cytotoxic to the skin. The aggressive medical-grade acrylic copolymer adhesive maximises adhesion under diaphoretic (sweating) and stress conditions. All electrodes are latex-free and exceed the performance specifications of the ANSI/AAMI EC 12 standard (DC offset voltage ≤ 0.5 mV versus the AAMI limit of ≤ 100 mV).
3. Technical Specifications
Main features of the FS 501 S electrode (reference Cahnos 11322):
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 11322 |
| Model / family | FS 501 S (Medi Sensor Monitoring line) |
| Type | Conventional disposable electrode for exercise stress testing |
| Backing material | Foam (medical foam) |
| Gel | Solid conductive gel (polymerised hydrogel) |
| Measurements | 45 x 35 mm |
| Connection | Central press stud (snap) |
| Adhesive | Medical-grade aggressive (non-sensitising acrylic copolymer) |
| Composition | Latex-free; non-irritating, non-sensitising gel |
| Presentation | Bag of 50 units |
| Minimum sales unit | Box of 2,000 units |
| Application | Stress testing and cardiovascular monitoring |
| Use | Single-use, for clinical and hospital use |
| Electrical performance | DC offset voltage ≤ 0.5 mV (ANSI/AAMI EC 12 limit: ≤ 100 mV) |
Note: the data on dimensions, material, gel and presentation come from the manufacturer’s technical documentation; confirm with the supplied batch data sheet the exact type of connector (snap-type press stud or forceps) for its fit with the patient cable of the monitor fleet.
4. Equivalences and Cross-References
Reference 11322 (model FS 501 S) is the Cahnos distribution code for this adult foam electrode with solid gel; there is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with third-party brands. The following references share the same category (disposable foam ECG electrode with snap connection for stress testing and adult monitoring) and have a code confirmed in the GUDID regulatory database, the manufacturer’s official catalogue or authorised technical distribution. They are classified as comparable by category, not interchangeable 1:1: each field must be verified (dimensions, gel type, geometry and connector position) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| 3M / Solventum | Red Dot™ Monitoring Electrode – foam with sticky gel (solid adhesive gel), diaphoretic | 2560 (GUDID 00707387789305 / 10707387789302) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID and official catalogue: foam with solid adhesive gel, snap connection, dimensions 4 x 3.5 cm in rectangular format and indicated for diaphoretic and stress monitoring. Differs: rectangular geometry versus the 45 x 35 mm format; verify contact surface and cable fit before substituting. |
| Cardinal Health | Kendall™ Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) | 31013926 (series 530) | Comparable by category (not interchangeable 1:1) | Code confirmed in Cardinal Health’s official catalogue and authorised distribution: foam with conductive adhesive hydrogel (solid gel), snap connection, drop shape of approx. 44 mm, indicated for stress, Holter and diaphoretic monitoring, in accordance with ANSI/AAMI EC 12. Differs: drop geometry versus the rectangular 45 x 35 mm format. |
| Ambu (Denmark) | BlueSensor™ R – foam electrode with wet gel (adult) | R-00-S / R-00-S/25 (GUDID 05707480022205) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID and Ambu’s official catalogue: foam, highly conductive wet gel, Ag/AgCl sensor and offset snap connector, approx. 57 x 48 mm (48 mm effective). Differs: gel type (wet versus solid) and offset connector versus the central snap of this reference; validate cable fit before substituting. |
| Leonhard Lang (Skintact®) | FS-50 – exercise stress test electrode with foam and Aqua-Wet™ liquid gel | FS-50 | Comparable by category (not interchangeable 1:1) | Code confirmed in Leonhard Lang’s official catalogue: PE foam, Aqua-Wet™ liquid gel, snap connector, Ø 50 mm, reinforced adhesive, indicated for stress testing, emergency care and echocardiography. Differs: gel type (liquid versus solid) and 50 mm diameter versus the 45 x 35 mm format. |
There is no manufacturer-validated equivalence table authorising 1:1 substitution between brands of stress test electrodes: the type of backing, the type of gel (liquid or solid), the dimensions and the connector position condition adhesion and signal quality. Any substitution must be validated against the technical data sheet and instructions for use of the electrode manufacturer and the monitoring system, checking one by one dimensions, backing, gel and connector; consult the Cahnos technical department before use in tendering.
5. Selection tips and variants of interest
Solid gel, the choice for demanding conditions: this FS 501 S electrode offers the advantages of solid gel (no liquid residue, fast signal response and low impedance) with the impermeable backing of foam, ideal for stress tests with intense sweating. Its 45 x 35 mm format with central snap is the most common standard in ergometer and monitor cables.
Variants within the Cahnos catalogue: if you prefer the same foam and solid gel backing in a circular format, you have the ST 50 RFI electrode of Ø 50 mm for ECG and stress testing (ref. 0590028, box of 600 units) and the NM 3642 OFI electrode of 45 x 42 mm with solid gel (ref. 0590027). For stress testing with liquid gel, the family includes the FS 50 L of Ø 50 mm (ref. 11312), the F 55 L of Ø 55 mm (ref. 11310) and the ST 50 RLI of Ø 50 mm with high adhesion (ref. 0590024); for monitoring and stress testing in the Top Trace line, the NM 55 RLI of Ø 55 mm (ref. 14709). If imaging control is anticipated, consider the radiotransparent versions RT 50 RFI (ref. 0590022) or F 50 S BLUE (ref. 15843). All share the same clinical indication but differ in backing, gel, diameter or connection: adapt the choice to your monitor fleet and the connector type of your patient cables.
Preparation and storage: clean and dry the skin before application and avoid creams or oily residues to optimise contact impedance. Keep the bags sealed in a dry, cool place, rotate stock on a FIFO basis and respect the expiry date: solid gel may lose conductivity if the packaging is opened or damaged. For volume orders, complete supplies or tenders, contact the technical-commercial department of Cahnos, indicating the model of your monitor fleet and the type of connection.





Reviews