We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable ECG electrode for stress testing FS 50 L – Foam with liquid gel Ø 50 mm – Bag of 30 units and box of 120 units (Ref. Cahnos 11312)

3,06 €

FS 50 L electrode for stress testing and cardiac monitoring: disposable ECG electrode in foam (medical foam) with conductive liquid gel, circular format of Ø 50 mm. Firm adhesion, low impedance and stable signal even with intense sweating during ergometry. Presentation in a bag of 30 units with a minimum box of 120 units: high-turnover consumable for cardiology departments, ergometry units, sports medicine and centralised purchasing, with excellent cost per procedure. Latex-free; confirm the batch connector (press stud) according to the monitor’s patient cable.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
11312

Description

1. Commercial Introduction

The FS 50 L electrode (reference Cahnos 11312) is a disposable surface ECG consumable, manufactured in medical foam (foam) with conductive liquid gel, in a circular format of Ø 50 mm. It is specifically designed for exercise stress testing or ergometry and cardiac monitoring in adult patients, where the demand for adhesion and signal stability is maximum during physical exercise. Its excellent value for money and its high-turnover format (bag of 30 units with a minimum box of 120) make it the reference solution for cardiology departments, ergometry rooms, sports medicine, hospitals and purchasing centres that need a reliable electrode, comfortable for the patient and with a very competitive cost per procedure.

2. Technical Explanation

A surface ECG electrode acts as an interface between the patient’s skin and the monitor or recorder of the exercise stress test: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study, even with sweating), conductivity (low skin-electrode contact impedance) and stability against movement.

The foam support is flexible, lightweight and moisture-resistant: it protects the gel and the sensor, adapts to the contour of the thorax and withstands the demanding conditions of an exercise stress test. The conductive liquid gel, formulated with salts (potassium chloride), ensures very rapid signal acquisition and low impedance from the first seconds of the recording, reducing the movement artefacts typical of ergometry. It is a single-use product, for clinical and hospital use, of hypoallergenic composition and latex-free, which meets the performance requirements of the ANSI/AAMI EC 12 standard for disposable ECG electrodes.

3. Technical Specifications

Main characteristics of the FS 50 L electrode (reference Cahnos 11312), according to technical documentation of the Medi Sensor Monitoring line:

Parameter Specification
Reference Cahnos (SKU) 11312
Model / family FS 50 L (Medi Sensor Monitoring line)
Type Conventional disposable electrode for exercise stress testing
Backing material Foam (medical foam)
Gel Conductive liquid gel (rapid signal acquisition, low impedance)
Diameter Ø 50 mm (circular format)
Presentation Bag of 30 units
Minimum sales unit Box of 120 units
Application Exercise stress testing (ergometry) and cardiac monitoring in adults
Advantages High adhesion, precise signal, comfortable for the patient
Composition Hypoallergenic, latex-free
Use Single-use, disposable; for clinical and hospital use
Reference standards ANSI/AAMI EC 12 (performance requirements); medical device with CE marking
Storage Store in a cool, dry place in sealed packaging until use

Note: confirm with the supplied batch sheet the exact type of connector (snap-type press stud or clip) for its fitting with the patient cable of the monitor fleet.

4. Equivalences and Cross-References

Reference 11312 (model FS 50 L) is the Cahnos distribution code for this adult circular foam electrode with liquid gel; there is no equivalence table validated by the manufacturer that authorises a 1:1 cross-reference with third-party brands. The following references share the same category (disposable foam ECG electrode with wet/liquid gel and button connection for exercise stress testing and adult monitoring) and have a confirmed code in the GUDID regulatory database, official manufacturer catalogue or authorised technical distribution. They are classified as comparable by category, not interchangeable 1:1: each field must be verified (diameter, gel type, connector position and adhesive) before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Leonhard Lang (Skintact®) FS-50 – exercise stress test electrode with foam and Aqua-Wet™ liquid gel FS-50 (official catalogue; 30 units/bag, 1,200 units/box) Comparable by category (not interchangeable 1:1) Code confirmed in the official Leonhard Lang catalogue: PE foam, Aqua-Wet™ liquid gel, snap connector, Ø 50 mm, reinforced adhesive and indicated for exercise stress testing, emergency care and echocardiogram. It is the closest homologous reference as it matches in support, gel type, diameter and indication; verify connector position and adhesive of the specific batch before substituting.
Ambu (Denmark) BlueSensor R – foam electrode with wet gel (adult) R-00-S / R-00-S/25 (GUDID 05707480022205) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official Ambu catalogue: foam, highly conductive wet gel, Ag/AgCl sensor and offset snap connector; suitable for exercise stress testing. Dimensions 57 × 48 mm (48 mm effective): smaller diameter and offset connector compared to the Ø 50 mm of this reference; validate cable fitting before substituting.
3M / Solventum Red Dot™ Monitoring Electrode – foam with adhesive gel (sticky gel) 2560 (also V2560-5; GUDID 00707387789305) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official catalogue: foam with solid adhesive gel, snap connection and prolonged use validated for up to 5 days. Differences: solid gel versus the liquid gel of this reference and rectangular geometry of 4 × 3.5 cm versus the circular 50 mm format; verify contact surface and adhesion before substitution.
Cardinal Health (Kendall™) Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) 31013926 (series 530) Comparable by category (not interchangeable 1:1) Code confirmed in Cardinal Health’s official catalogue and authorised distribution: foam with conductive adhesive hydrogel (solid gel), snap connection, indicated for stress testing, Holter and diaphoretic monitoring (suggested use under 72 h), compliant with ANSI/AAMI EC 12. Differences: solid gel and teardrop shape of approx. 44 mm versus the circular 50 mm liquid gel.
Vermed (Nissha Medical) Performance Plus™ Foam Wet Gel Electrode – stress testing and Holter A10005-60 (60 units/bag) Comparable by category (not interchangeable 1:1) Code confirmed in authorised technical distribution: teardrop-shaped foam of 38 mm (1.5 in.), wet gel with high chloride content, Ag/AgCl sensor, aggressive hypoallergenic adhesive and snap connection; indicated for stress testing and Holter. Differences: geometry and diameter versus the circular 50 mm format.

There is no equivalence table validated by the manufacturer authorising 1:1 substitution between brands of stress testing electrodes: the type of backing, the type of gel (liquid or solid), the diameter and the connector position condition adhesion and signal quality. Any substitution must be validated against the technical data sheet and instructions for use from the manufacturer of the electrode and of the monitoring system, checking one by one diameter, backing, gel and connector; consult the technical department at Cahnos before using in tenders.

5. Selection tips and variants of interest

Liquid gel versus solid gel: the liquid gel of this reference provides very fast signal acquisition and low initial impedance, ideal for stress testing. If your department performs prolonged monitoring (Holter) or recordings with extreme sweating, consider the versions of the same family with solid gel, such as the ST 50 RFI electrode of Ø 50 mm (ref. 0590028) or the radiotransparent RT 50 RFI (ref. 0590022).

Diameter and format: this Ø 50 mm electrode offers an excellent balance between adhesive surface and comfort. If you prefer a larger adhesive surface, the F 55 L of Ø 55 mm with liquid gel (ref. 11310) or the NM 55 RLI from the Top Trace line (ref. 14709) are natural alternatives using the same technology. For stress testing with liquid gel and high adhesiveness, the ST 50 RLI of Ø 50 mm (ref. 0590024) is available and, for monitoring and resting ECG, the F 50 L (ref. 15492), both with identical backing and gel.

Check the connector: verify that the patient cable of your ergometer or monitor is compatible with button connection (snap-type press stud) before placing the order; if your installed base uses crocodile clips or banana connectors, consult the range of electrodes with tab and the connection adapters from Cahnos.

Preparation and storage: clean and dry the skin before application and avoid creams or oily residues to optimise contact impedance. Keep the bags closed in a cool, dry place, rotate stock on a FIFO basis and respect the expiry date: the liquid gel can lose conductivity if the packaging is opened or deteriorates. For volume orders, complete supplies or tenders, contact the technical-commercial department at Cahnos, indicating the model of your monitor installed base and the type of connection.

Additional information

Model / family

FS 50 L (Medi Sensor Monitoring line)

Product type

Disposable ECG electrode for exercise stress testing (ergometry)

Material

Foam (medical foam) with conductive liquid gel

Diameter

Ø 50 mm (circular format)

Connection

Snap connector (verify exact type with batch sheet)

Application

Exercise stress testing and cardiac monitoring in adults

Presentation

Bag of 30 units

Minimum sales unit

Box of 120 units

Use

Single-use, disposable; for clinical and hospital use

Regulatory standard

ANSI/AAMI EC 12; medical device with CE marking

Advantages

High adhesion, precise signal, comfortable for the patient

Backing material

Foam (medical foam)

Gel

Conductive liquid gel (rapid signal acquisition, low impedance)

Storage

Cool, dry place; keep sealed until use

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Disposable ECG electrode for stress testing FS 50 L – Foam with liquid gel Ø 50 mm – Bag of 30 units and box of 120 units (Ref. Cahnos 11312)”

Your email address will not be published. Required fields are marked *