Description
1. Introduction
The reusable neonatal SpO₂ sensor (ref. 35216) is the reference consumable for non-invasive monitoring of oxygen saturation (SpO₂) and pulse rate in newborns, specifically designed to work with the pulse oximeter models 35152 and 35213. It is intended for low-weight patients (3-10 kg), the most delicate range of clinical monitoring, and its reusable nature makes it an economical and sustainable solution for neonatology, paediatrics, delivery room and critical care units.
2. Technical explanation
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin. The sensor emits light at two wavelengths (red and infrared) through the patient’s vascular bed, and a photodetector quantifies the differential absorption according to the degree of blood oxygenation, thus calculating the SpO₂ value and pulse rate displayed on the monitor.
This reusable neonatal sensor features a design specific to the newborn’s anatomy: a soft, ergonomic surface that gently adapts to the baby’s foot or hand, minimising the risk of pressure injuries and ensuring optimal contact for a stable signal. Being reusable, it can be cleaned and disinfected between patients following the centre’s protocol, which reduces the cost per use compared to disposable sensors in medium-turnover units.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Sensor type | Reusable neonatal SpO₂ pulse oximetry sensor |
| Manufacturer reference | 35216 |
| Manufacturer | GIMA |
| Patient population | Neonates 3 to 10 kg |
| Compatibility | Pulse oximeters Ref. 35152 and 35213 |
| Use | Reusable |
| Application | Monitoring of SpO₂ and pulse rate in neonates |
| Sales unit | 1 pc |
Product data
| Field | Value |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040110149 |
4. Equivalences and Cross-References
Reference 35216 corresponds to the manufacturer’s reusable neonatal sensor and is sized for use with the same brand’s pulse oximeters 35152 and 35213, as indicated in the manufacturer’s official catalogue (Product_DB). We do not have a validated equivalence table that cross-references this reference with sensors from other manufacturers on a 1:1 interchangeable basis: before replacing the original sensor with one from another brand, electrical and connector compatibility with the specific monitor installed at the centre must always be verified.
| Reference / Model | Description | Related items |
|---|---|---|
| 35216 | Reusable neonatal SpO₂ sensor for 3-10 kg | Main product (this item) |
| 35152 | Pulse oximeter compatible with this sensor | Compatible equipment (manufacturer) |
| 35213 | Pulse oximeter compatible with this sensor | Compatible equipment (manufacturer) |
To confirm compatibility with other monitors or for tender requirements, please contact our technical-commercial department.
5. Selection tips and variants of interest
Verify your monitor: this sensor is indicated for the pulse oximeters Ref. 35152 and 35213. If your department uses other brands or models, please let us know the equipment to confirm exact compatibility before placing the order.
Weight range: with a neonatal profile of 3 to 10 kg, it is the appropriate size for most full-term newborns and premature infants under follow-up. For heavier paediatric patients, please consult the paediatric sensors in the catalogue.
Maintenance of the reusable sensor: clean and disinfect the catheter between patients according to the manufacturer’s instructions and your centre’s protocol. Avoid sharp bends in the cable and periodically check the optical surface to ensure reliable readings.
Spare stock: as this is a frequently used reusable consumable, we recommend maintaining a sufficient number of units per monitoring station to ensure continuity of care and rotation during cleaning.
For institutional orders, volume conditions or supply contracts, please contact our B2B technical-commercial team.