We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Radiotransparent ECG electrode RT 50 RFI of foam and solid gel Ø 50 mm with snap – Clinical monitoring, Holter, magnetic resonance imaging and stress testing – Ref. Cahnos 0590022

4,66 €

Disposable ECG electrode radiotransparent RT 50 RFI of foam and solid gel, in a circular format of Ø 50 mm with a centred translucent snap, suitable for X-ray and magnetic resonance imaging without interrupting monitoring. Carbon and Ag/AgCl sensor, low impedance (77 Ω at 10 Hz), aggressive medical-grade acrylic adhesive and latex-free composition, compliant with ANSI/AAMI EC 12. Presentation in a bag of 30 units; minimum box of 600 units. Ideal for ICU, operating theatre, recovery room, Holter, stress testing and difficult adhesion environments.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0590022

Description

1. Commercial Introduction

The radiotranslucent monitoring electrode RT 50 RFI (reference Cahnos 0590022) is a disposable ECG electrode made of circular foam, 50 mm in diameter, with conductive solid gel, designed to provide accurate and reliable signal transmission during continuous patient monitoring. Its radiotranslucent snap button is particularly suitable for X-ray and MRI examinations, making it the reference consumable for cardiology departments, ICU, CCU, operating theatre, recovery room, cardiac rehabilitation and stress testing. Supplied in a bag of 30 units with a minimum box of 600 units, it is the high-turnover solution for hospitals, clinics and medical transport companies that require an electrode with excellent adhesion in demanding conditions.

2. Technical Explanation

This electrode is a Class I medical device with CE marking (Directive 93/42/EEC), verified in accordance with the US voluntary standard ANSI/AAMI EC 12:2000/(R)2005, which defines the performance requirements for disposable ECG electrodes. It is manufactured with a foam coated with an aggressive non-sensitising acrylic copolymer, which maximises adhesion even in diaphoretic (sweating) and stressful conditions, maintaining a low skin-electrode interface impedance. The conductive solid gel is presented in a central column and maintains its aqueous content in a polymerised hydrogel formulation: it is non-irritating, non-sensitising and non-cytotoxic to the skin, and all components are latex-free.

The special radiotranslucent snap button and the carbon/Ag-AgCl sensor material prevent artefacts in imaging studies, so the electrode can remain in place during X-rays or MRI scans without interrupting monitoring. It is indicated for standard and continuous monitoring, Holter recording, stress tests and any challenging adhesion environment: ICU/CCU, operating theatre, recovery room, cardiac rehabilitation or dental surgery.

3. Technical Specifications

Main features of the RT 50 RFI electrode (reference Cahnos 0590022):

Parameter Specification
Reference Cahnos (SKU) 0590022
Model / family RT 50 RFI (radiotranslucent electrode range for monitoring)
Type Conventional foam and solid gel electrode for monitoring
Material Foam (medical foam) and solid gel
Diameter Ø 50 mm (circular format)
Presentation Bag of 30 units
Minimum sales unit Box of 600 units
Application Monitoring in clinical settings
Advantages Excellent adhesion, high transmission reliability, comfortable for the patient
Use Clinical, especially in continuous monitoring

3.1 Electrical characteristics (according to manufacturer’s technical data sheet)

Electrical parameter Product value ANSI/AAMI EC 12 limit
DC offset voltage 0.15 mV ≤ 100 mV
AC impedance at 10 Hz 77 Ω ≤ 2000 Ω
DC offset at 5 s after capacitor discharge 1.9 mV ≤ 100 mV
Recovery slope (30 s interval) 0.1 mV/s ≤ 1 mV/s
AC impedance after defibrillation 120 Ω ≤ 3000 Ω
Parameter Specification
Sensor material Carbon and Ag/AgCl (radiotranslucent snap button)
Radiotransparency Yes: radiotranslucent snap button suitable for X-ray and MRI
Connection type Centered radiotranslucent snap button
Adhesive Medical-grade acrylic copolymer, aggressive and non-sensitising
Composition Polymerised hydrogel; non-irritating, non-sensitising, non-cytotoxic; latex-free
Packaging 30 units/aluminium foil pouch; 600 units/box; 7,200 units/master carton
Expiry 36 months in sealed packaging
Regulatory standard ANSI/AAMI EC 12:2000/(R)2005; Directive 93/42/EEC; Class I medical device with CE marking

Note: the electrical values come from the batch technical data sheet published by the manufacturer (REF. 0590022); confirm with the supplied batch certificate before use in tenders.

4. Equivalences and Cross-References

Code 0590022 is the Cahnos distribution reference for this radiotransparent adult monitoring electrode; it is not an official reference of the monitoring equipment manufacturer, but a standard consumable with snap connector. The following cross-references have a confirmed code in public sources (GUDID regulatory databases, official manufacturer catalogue or authorised technical distribution) and are classified as comparable at category level: same function (adult ECG monitoring with snap connector), but with verifiable differences in geometry, gel, adhesive or radiotransparency that prevent them from being considered 1:1 interchangeable without prior validation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Leonhard Lang (Skintact®) F-601 C – MR-conditional monitoring electrode with foam and solid gel F-601C Comparable by category (not interchangeable 1:1) Code confirmed in Leonhard Lang official catalogue: PE foam, solid gel, Ø 50 mm, carbon snap connector, suitable for X-ray and MRI (X-ray/MR-conditional); presentation of 30 units/bag. It is the closest homologous reference as it matches in dimensions, gel type and radiotransparency; the adhesive differs (standard vs. the aggressive acrylic of this technical data sheet) and the box format (1,500 units vs. 600 units). Verify adhesion and snap fit with the cable before replacement.
3M / Solventum Red Dot™ Monitoring Electrode with foam and sticky gel (solid adhesive gel) 2560 (also V2560-5) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID (DI 00707387789305) and official Solventum/3M catalogue: radiotransparent (radiolucent) foam electrode, solid adhesive gel, snap connection, for adult monitoring, validated for prolonged use (up to 5 days). It differs in geometry: rectangular shape of 4 x 3.5 cm vs. the circular format of Ø 50 mm. Its IFU warns that the metal snap is not tested for magnetic resonance imaging: verify contact surface, adhesion and compatibility with the cable before replacement.
Cardinal Health Kendall™ Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) 31013926 (series 530) Comparable by category (not interchangeable 1:1) Code confirmed in Cardinal Health official catalogue and authorised technical distribution (McKesson, Henry Schein): thick white foam electrode, conductive adhesive hydrogel (solid gel), snap connection, ANSI/AAMI EC 12 compliance, use in stress, Holter and diaphoretic monitoring with suggested use time of less than 72 h. Drop shape of approx. 44 mm; radiotransparency has not been confirmed for this specific SKU in public sources. Verify batch radiotransparency, geometry and adhesive before replacement.
Ambu BlueSensor™ R (adult, foam, snap) R-00-S / R-00-S/5 (GUDID 05707480022205) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official Ambu catalogue: radiotransparent (radiolucent) foam electrode for adults with Ag/AgCl sensor and offset snap connector, approx. 57 x 48 mm. Key difference: highly conductive wet gel vs. the solid gel of this reference, and off-centre connector vs. the centred snap. Suitable for stress testing and monitoring; verify gel type and connector fit before replacement.
FIAB (Italy) F9069RM – radiotransparent adult foam and solid gel electrode with carbon clip F9069RM Comparable by category (not interchangeable 1:1) Code confirmed in FIAB official catalogue: foam (FOAM), solid gel, Ag/AgCl sensor and non-magnetic carbon clip (snap), radiotransparent, indicated for operating theatre, magnetic resonance imaging and CT. It differs in geometry: oval format of 42 x 45 mm vs. the circular format of Ø 50 mm, and presentation of 50 units/bag with box of 1,200 units. Verify contact surface and connector fit before replacement.

There is no manufacturer-validated equivalence table authorising 1:1 replacement between monitoring electrode brands: geometry, gel type, radiotransparency and active surface determine signal quality and adhesion. Any replacement must be validated against the technical data sheet and instructions for use of the electrode manufacturer and the monitoring system, checking one by one diameter, gel, connector and radiotransparency; consult the Cahnos technical department before use in tenders.

5. Selection tips and variants of interest

Select according to clinical use: this RT 50 RFI electrode is 50 mm, solid gel and radio-translucent snap, ideal for continuous monitoring, Holter and stress tests with possible imaging control. If you need a multifunction radiotransparent electrode for monitoring and ECG from the same family, the reference 15843 is available (F 50 S BLUE, foam and solid gel, Ø 50 mm, box of 120 units).

Choose radiotransparent when imaging tests are anticipated: if the patient may require X-ray or magnetic resonance imaging during monitoring, this version with translucent snap avoids artefacts without removing the electrode. If imaging is not required, the standard version of the same family with liquid gel (reference 0590024, ST 50 RLI) or with solid gel for stress testing (0590028, ST 50 RFI) may be considered, adapting the format to the department protocol.

Variants of the same family at Cahnos: rectangular electrode 28 x 44 mm with solid gel and banana connector (0590025, NM 2844 FBI), rectangular 28 x 44 mm for resting and ECG (16115, NM 2844 RFS), oval 51 x 33 mm (0590026), 45 x 42 mm format with solid gel and Ag/AgCl sensor (0590027, NM 3642 OFI) and paediatric version Ø 30 mm (0590016, NM 30 RFI). All share foam and gel technology but differ in size, geometry and connection type: check the cable and clip of your system (snap, banana or 4 mm) before selecting.

Storage and expiry: store in a dry, cool place, in the closed packaging (aluminium sachet) until use, and respect the 36-month expiry date; solid gel may lose conductivity if exposed to air. As it is a single-use consumable, maintain a minimum stock per monitoring station and rotate stock (FIFO). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the monitor model and connector type of your installed base.

Additional information

Product type

Disposable ECG monitoring electrode, radiotranslucent, with snap button

Model / family

RT 50 RFI

Backing material

Foam (medical foam)

Gel

Solid gel (polymerised hydrogel)

Sensor material

Carbon and Ag/AgCl

Diameter

Ø 50 mm (circular format)

Radiotransparency

Yes: suitable for X-ray and MRI

Intended use

Continuous monitoring, Holter, stress test, ICU/CCU, operating theatre, recovery room

Presentation

Bag of 30 units (aluminium foil pouch)

Minimum sales unit

Box of 600 units (7,200 units/master carton)

Main packaging

7,200 units / main carton

DC offset voltage

0.15 mV (ANSI/AAMI EC 12 limit: ≤ 100 mV)

AC impedance 10 Hz

77 Ω (ANSI/AAMI EC 12 limit: ≤ 2000 Ω)

DC offset 5 s

1.9 mV (ANSI/AAMI EC 12 limit: ≤ 100 mV)

Recovery slope 30 s

0.1 mV/s (ANSI/AAMI EC 12 limit: ≤ 1 mV/s)

Shelf life

36 months in sealed packaging

Regulatory standard

ANSI/AAMI EC 12:2000/(R)2005; Directive 93/42/EEC; Class I medical device with CE marking

Connector

Radiotranslucent snap button

Use

Single-use, disposable, non-sterile, latex-free

Reference

0590022

Model

RT 50 RFI

Type

Disposable ECG monitoring electrode (foam and solid gel)

Connection

Centered radiotranslucent snap button

Adhesive

Medical-grade acrylic copolymer, aggressive and non-sensitising

AC impedance defibrillation

120 Ω (ANSI/AAMI EC 12 limit: ≤ 3000 Ω)

Indications

Continuous monitoring, Holter, stress tests, ICU/CCU, operating theatre, recovery room, MRI

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Radiotransparent ECG electrode RT 50 RFI of foam and solid gel Ø 50 mm with snap – Clinical monitoring, Holter, magnetic resonance imaging and stress testing – Ref. Cahnos 0590022”

Your email address will not be published. Required fields are marked *