Description
1. Commercial Introduction
The F 50 L electrode (reference Cahnos 15492) is a disposable surface ECG consumable made of medical foam with conductive liquid gel, in a circular format of Ø 50 mm. It is indicated for cardiac monitoring and obtaining resting electrocardiograms in adult patients, where a stable signal, secure adhesion and comfortable removal after the study are required. Its value for money and high-turnover format (bag of 30 units with a minimum box of 1,200) make it the reference option for cardiology departments, ICUs, emergency care, hospitalisation wards and purchasing centres that need a reliable electrode with excellent cost per procedure.
2. Technical Explanation
A surface ECG electrode acts as an interface between the patient’s skin and the monitor or electrocardiograph: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study), conductivity (low skin-electrode contact impedance) and stability against movement.
The foam support (medical foam) is flexible, light and moisture-resistant: it protects the gel and the sensor, adapts to the contour of the chest and maintains its integrity during resting recordings and continuous monitoring. The conductive liquid gel ensures rapid signal capture and low impedance from the start of the recording, reducing the risk of artefacts and repeats due to poor signal. This is a single-use product, for clinical and hospital use, which must be disposed of after each patient; keep the container closed in a dry, cool place and respect the expiry date so as not to compromise the conductivity of the gel.
3. Technical Specifications
Main features of the F 50 L electrode (reference Cahnos 15492):
| Parameter | Specification |
| Reference Cahnos (SKU) | 15492 |
| Model / family | F 50 L (Medi Sensor Monitorizacion line) |
| Type | Conventional disposable electrode for monitoring and ECG |
| Material | Foam (medical foam) with conductive liquid gel |
| Shape | Circular |
| Diameter | Ø 50 mm |
| Presentation | Bag of 30 units |
| Minimum sales unit | Box of 1,200 units |
| Application | Cardiac monitoring and resting ECG in adult patients |
| Use | Clinical and hospital use; single-use product |
Note: the diameter, material and presentation data are taken from the distributor’s technical documentation; confirm with the supplied batch data sheet the exact type of connector (snap-type press stud or forceps) for its fitting with the patient cable of the monitor fleet.
4. Equivalences and Cross-References
Reference 15492 is the Cahnos distribution code for this adult circular foam electrode with liquid gel; there is no equivalence table validated by the manufacturer that authorises a 1:1 cross-reference with third-party brands. The following references share the same category (disposable foam ECG electrode with wet/liquid gel and button connection for monitoring and ECG in adults) and have a code confirmed in the GUDID regulatory database, official manufacturer catalogue or authorised technical distribution. They are classified as comparable by category, not interchangeable 1:1: each field must be verified (diameter, gel type, connector position and adhesive) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Leonhard Lang (Skintact®) | FS-50 – exercise stress test electrode with foam and Aqua-Wet™ liquid gel | FS-50 (official catalogue; 30 units/bag, 1,200 units/box) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official Leonhard Lang catalogue: PE foam, Aqua-Wet™ liquid gel, circular Ø 50 mm, snap connector, reinforced adhesive and Ag/AgCl sensor; indicated for stress testing, emergency care and monitoring. It matches in support, gel type, diameter and format; verify the connector position and adhesive of the specific batch before considering any substitution. |
| Ambu (Denmark) | BlueSensor R – foam electrode with wet gel (adult) | R-00-S / R-00-S/25 (GUDID 05707480022205) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID and official Ambu catalogue: foam, highly conductive wet gel, Ag/AgCl sensor and offset snap connector; suitable for monitoring and stress testing. Dimensions 57 × 48 mm (48 mm effective): slightly smaller diameter and offset connector compared to the Ø 50 mm of this reference; validate the cable fitting before substituting. |
| 3M / Solventum | Red Dot™ Monitoring Electrode with foam and adhesive gel | 2560 (also V2560-5; GUDID 00707387789305) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID and official catalogue: radiotransparent foam with solid adhesive gel, snap connection and prolonged use validated up to 5 days. Differs: solid gel compared to the liquid gel of this reference and rectangular geometry of 4 × 3.5 cm compared to the circular 50 mm format; verify contact surface and adhesion before substitution. |
| Cardinal Health (Kendall™) | Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) | 31013926 (series 530) | Comparable by category (not interchangeable 1:1) | Code confirmed in official Cardinal Health catalogue and authorised distribution: foam with conductive adhesive hydrogel (solid gel), snap connection, indicated for stress, Holter and diaphoretic monitoring (suggested use less than 72 h), compliant with ANSI/AAMI EC 12. Differs: solid gel and drop shape of approx. 44 mm compared to the circular liquid gel of 50 mm. |
| Vermed (Nissha Medical) | Performance Plus™ Foam Wet Gel Electrode – stress testing and Holter | A10005-60 (60 units/bag) | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised technical distribution: drop-shaped foam of 38.1 mm (1.5 in.), wet gel with high chloride content, Ag/AgCl sensor, aggressive hypoallergenic adhesive and metallic snap connection; indicated for stress testing and Holter. Differs: geometry and diameter compared to the circular 50 mm format. |
| FIAB (Italy) | F9060 – oval foam and solid gel electrode for adult | F9060 (official catalogue; 50 units/bag, 1,200 units/box) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official FIAB catalogue: foam, solid gel, Ag/AgCl sensor and snap connection, indicated for resting, long-term monitoring, stress testing and Holter. Differs: solid gel compared to the liquid gel of this reference and oval geometry of 48 × 50 mm compared to the circular 50 mm format; verify contact surface and connector fitting before substitution. |
There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender.
5. Selection tips and variants of interest
Choose the diameter according to the protocol: this Ø 50 mm electrode offers a large adhesive surface for monitoring and resting ECG in adults. If you prefer the same backing and gel in a larger format, you have the foam electrode with liquid gel Ø 55 mm (ref. 11310, model F 55 L, box of 1,200 units) and the foam electrode with liquid gel Ø 55 mm from the Top Trace line (ref. 14709, model NM 55 RLI); for stress testing with the same diameter, the foam electrode with high-adhesion liquid gel (ref. 0590024, model ST 50 RLI) or the FS 50 L (ref. 11312); and if you prefer solid gel in a circular Ø 50 mm format, the NM 50 RFI electrode (ref. 13628) or the ST 50 RFI for Holter and stress (ref. 0590028).
Liquid gel vs. solid gel: the liquid gel in this reference provides very fast signal acquisition and low initial impedance, ideal for resting ECG and short-term monitoring. If your department performs prolonged monitoring or recordings with heavy sweating, consider the versions of the same family with solid gel, such as the foam electrode with solid gel for stress and Holter (ref. 0590028, model ST 50 RFI), the NM 3642 OFI solid gel electrode (ref. 0590027) or the radiotransparent Ø 50 mm electrode (ref. 0590022); for stress testing with solid gel in a rectangular format, you have the FS 501 S of 45 × 35 mm (ref. 11322).
Check the connection: confirm the connector type (snap press stud, forceps or adapter) of the patient cable in your monitor fleet and contact us if you need adapters or electrodes with a tab.
Preparation and storage: clean and dry the skin before application and avoid creams or oily residues to optimise contact impedance. Keep the bags closed in a cool, dry place, rotate stock on a FIFO basis and respect the expiry date: the liquid gel may lose conductivity if the packaging is opened or damaged. For volume orders, complete supplies or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection.





Reviews