Paediatric finger clip SpO2 sensor for PROview and AnyView monitors
The finger clip SpO2 sensor for children is a high-quality monitoring accessory from the brand APK Technology, distributed by medical ECONET GmbH, intended as a replacement or additional sensor for the patient monitors of the PROview and AnyView series. Specifically designed for paediatric patients, it guarantees reliable and comfortable reading of oxygen saturation and pulse in daily clinical practice, both in outpatient consultations and hospitalisation services.
Technical explanation of the sensor
The sensor works using the transmission pulse oximetry technique: two light emitters (red and infrared) pass through the vascular bed of the finger and a photodetector records the absorption variations of the pulse wave. With this data, the monitor calculates in real time the functional oxygen saturation (SpO2) and heart rate. Its finger clip format facilitates quick, stable and comfortable placement, minimising motion interference, which is especially important in restless paediatric patients. The 3-metre connection cable offers ample freedom of positioning of the patient relative to the monitor.
Technical specifications
| Sensor type | Paediatric finger clip SpO2 (finger clip) |
| Target population | Children / paediatric patients |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
| Compatibility | PROview 10 lite, PROview 10, PROview 12 |
| Additional compatibility | AnyView M10, AnyView S10, AnyView S12 |
| Cable length | 3 m |
| Manufacturer | APK Technology (via medical ECONET GmbH) |
| References | MEC21.13-5272 / 21.13-5272 / EAN 6946725541166 |
Available references
| Article no. medical ECONET | 21.13-5272 |
| Reference Cahnos (SKU) | MEC21.13-5272 |
| EAN code | 6946725541166 |
Equivalences and cross-references
Within the same range from the manufacturer APK Technology / medical ECONET, this paediatric sensor corresponds to the children’s version for the PROview and AnyView series. In the original catalogue there are versions of the same type of sensor (finger clip) covering other monitor ranges, as well as adult variants and sensors of other types (softtouch and wrapsensor) with different application ranges. No equivalences with other pulse oximetry manufacturers are indicated as they have not been verified in reliable catalogue sources.
Selection tips and variants of interest
To choose the correct sensor, always check the exact model of the monitor and the type of patient to be monitored: this model is the paediatric (children’s) version with a 3 m cable. For adult patients of the same PROview and AnyView series, there is a corresponding adult finger clip version. If you work with monitors from other ranges (for example, Palmcare or Compact series), verify the specific compatibility of each SpO2 sensor variant before purchasing the replacement. Consult our technical-commercial team to confirm the exact fit with your fleet of monitors.