Description
1. Introduction
The adult soft-finger SpO2 pulse oximeter catheter for Philips is the reusable replacement your department needs to maintain continuous monitoring of oxygen saturation on Philips vital signs monitors. Manufactured to Philips OEM standard, it ensures direct integration, stable readings and a comfortable fit on the patient’s finger.
It is the ideal solution for hospitals, clinics, emergency departments, ICUs, operating theatres and hospital wards that work with Philips monitors and are looking for a proven-quality spare part, ready to use and available in two cable lengths to suit the configuration of each monitoring station.
2. Technical explanation
Pulse oximetry is a non-invasive technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed of the finger and detects differential absorption according to the degree of blood oxygenation. The signal is transmitted to the monitor via the catheter connector, which follows the electrical standard of Philips equipment.
This sensor is specifically designed for adult patients, with a soft-finger contact area that offers comfortable, stable placement and good signal quality during continuous monitoring. As a reusable sensor, it allows prolonged use by following the manufacturer’s cleaning and maintenance instructions.
3. Technical Specifications
Adult SpO2 pulse oximeter sensor, compatible with the indicated Philips monitor family. The available references and product data are detailed below.
Available references
| Reference | Cable length | Sales unit |
|---|---|---|
| GM35279 | 1.6 m cable | 1 ud |
| GM35280 | 3.0 m cable | 1 ud |
Product data
| Manufacturer | GIMA |
|---|---|
| Sensor type | Adult soft-finger type |
| OEM standard | Philips (N: 2) |
| Cable length | 1.6 m |
| Compatible with | Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8 |
| Instruction manual | GB, FR, IT, ES |
| Sales unit | 1 ud |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
4. Equivalences and Cross-References
This product is supplied under Philips OEM standard, so it is designed as a direct replacement for the pulse oximeter catheters of Philips M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6 and VM8 monitors. References GM35279 (1.6 m cable) and GM35280 (3.0 m cable) are the two variants of the same sensor family, differing only in cable length.
There is no manufacturer-validated equivalence table cross-referencing this part with specific codes from other manufacturers on a 1:1 interchangeable basis; before replacing a catheter from another brand, it is recommended to verify compatibility with the exact monitor model through Cahnos’s technical-commercial department.
5. Selection tips and variants of interest
Identify the exact monitor: verify that your equipment corresponds to the Philips M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6 or VM8 family before placing the order; always indicate the monitor model to confirm compatibility.
Choose the appropriate cable length: reference GM35279 (1.6 m cable) is ideal for bedside stations with the monitor close to the patient, while GM35280 (3.0 m cable) offers greater reach for beds, transports or configurations where the distance to the monitor is greater.
Maintenance: as a reusable sensor, follow the manufacturer’s cleaning and care instructions between patients to extend its service life and ensure reliable readings; do not immerse the connector or use sterilisation methods not indicated.
Always request the full reference (GM35279 or GM35280) to avoid order confusion. For B2B supply contracts and volume purchases, consult our technical-commercial team.





Reviews