We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Electrode for monitoring and ECG, foam in the shape of a water drop Ø 42 mm with solid gel – Model NM 42 DFI (Ref. Cahnos 0590029) – Bag of 50 units, box of 1,200 units.

4,03 €

Electrode NM 42 DFI (Ref. Cahnos 0590029) for cardiac monitoring and ECG: disposable consumable made of medical foam in the shape of a water drop of 45 × 42 mm, with conductive solid gel, Ag/AgCl sensor and snap-type press stud. Designed for rest, continuous monitoring and Holter in adult patients, it maintains a stable low-impedance signal thanks to its medical-grade acrylic adhesive and its polymerised hydrogel gel: non-irritating, non-sensitising and latex-free, in accordance with ANSI/AAMI EC 12. Presentation in a bag of 50 units and minimum sales unit of a box of 1,200 units. High-turnover solution for cardiology, ICU, emergency and hospitalisation.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0590029

Description

1. Product Presentation

The electrode NM 42 DFI (reference Cahnos 0590029) is the disposable consumable of the Top Trace Monitoring line for cardiac monitoring and obtaining electrocardiograms in adult patients. Its medical foam support in the shape of a water drop, its central column of conductive solid gel and its medical-grade adhesive ensure firm and comfortable fixation, with stable signal transmission from the start of the recording.

Presented in a bag of 50 units and with a minimum sales unit of a box of 1,200 units, it is the high-turnover solution for cardiology departments, ICUs, emergency rooms, hospitalisation wards and purchasing centres looking for a reliable electrode with excellent cost per procedure.

2. Technical Explanation

A surface ECG electrode acts as an interface between the patient’s skin and the monitor or electrocardiograph: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on three factors: adhesion (the electrode must remain fixed throughout the study), conductivity (low skin-electrode contact impedance) and stability against movement.

The foam support (medical foam) is flexible and light: it protects the gel and the sensor, adapts to the contour of the chest and maintains its integrity during resting recordings and continuous monitoring. The water drop (teardrop) shape optimises the contact surface with a comfortable profile for the patient. The conductive solid gel, formulated as a polymerised hydrogel in a central column, does not drip or shift, retains its aqueous content during prolonged recordings and eliminates the mess of liquid gels, maintaining stable conductivity over the hours. The set is non-irritating, non-sensitising, non-cytotoxic and latex-free, and meets the performance requirements of the voluntary standard ANSI/AAMI EC 12 for disposable ECG electrodes. It is a single-use product, for clinical and hospital use, which must be discarded after each patient.

3. Technical Specifications

Main characteristics of the NM 42 DFI electrode (reference Cahnos 0590029), according to the manufacturer’s technical data sheet:

Parameter Specification
Reference Cahnos (SKU) 0590029
Model / family NM 42 DFI (Top Trace Monitoring line)
Type Conventional disposable electrode for monitoring and ECG
Backing material White foam (medical foam) with aggressive medical-grade acrylic adhesive
Shape Water drop (teardrop), centred snap
Measurements 45 × 42 mm (commercial diameter Ø 42 mm)
Gel Conductive solid gel (polymerised hydrogel) in a central column
Sensor material Ag/AgCl (silver/silver chloride)
Connection type Snap-type press stud
Presentation Bag of 50 units
Minimum sales unit Box of 1,200 units
Main packaging 14,400 units / master carton
Composition Non-irritant, non-sensitising, non-cytotoxic; latex-free
Application Cardiac monitoring, resting ECG, standard recording and Holter
Use Single-use, disposable, non-sterile
Expiry 36 months in sealed packaging
Reference standards ANSI/AAMI EC 12:2000/(R)2005; Directive 93/42/EEC; Class I medical device with CE marking

Electrical characteristics (manufacturer’s technical data sheet):

Electrical parameter Product value ANSI/AAMI EC 12 limit
DC offset voltage 0.12 mV ≤ 100 mV
AC impedance at 10 Hz 60 Ω ≤ 2000 Ω
DC offset at 5 s after capacitor discharge 6.5 mV ≤ 100 mV
Recovery slope (30 s interval) 0.0 mV/s ≤ 1 mV/s
AC impedance after defibrillation 46 Ω ≤ 3000 Ω

Note: the technical data come from the Top Trace line documentation and the manufacturer’s data sheet (REF. 0590029); confirm the values of the supplied batch with its certificate before use in tendering.

4. Equivalences and Cross-References

Reference 0590029 (model NM 42 DFI) is the Cahnos distribution code for this adult foam electrode in drop shape with solid gel; it is a standard consumable with snap connector, not an official reference of the manufacturer of the monitoring system. The following references share the same category (disposable foam ECG electrode with solid gel or adhesive hydrogel and button connection for adult monitoring) and have a confirmed code in the manufacturer’s official catalogue or GUDID regulatory database. They are classified as comparable by category, not interchangeable 1:1: each field must be verified (measurements, geometry, gel type and connector position) before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
FIAB (Italy) F9060 – foam and solid gel electrode, snap, adult F9060 Comparable by category (not interchangeable 1:1) Code confirmed in GUDID (08033695724304) and official catalogue: PE foam, solid gel, Ag/AgCl sensor, stainless steel snap, indicated for rest, long-term monitoring, stress and Holter. Oval geometry (48 × 50 mm) compared to the 45 × 42 mm drop; verify connector fit before substitution.
Leonhard Lang (Skintact®) F-601 – monitoring electrode with PE foam and solid gel F-601 Comparable by category (not interchangeable 1:1) Code confirmed in Leonhard Lang’s official catalogue: PE foam, solid gel, snap connector, Ø 50 mm, 30 units/bag and box of 1,200 units. Differs in geometry: circular format compared to the 45 × 42 mm drop. Verify contact surface and cable fit before substitution.
3M / Solventum Red Dot™ Monitoring Electrode with foam and sticky gel (solid adhesive gel) 2560 (also V2560-5) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID (00707387789305) and official catalogue: foam, solid adhesive gel, snap connection, Ag/AgCl sensor and prolonged use validated up to 5 days. Differs in geometry: rectangular 4 × 3.5 cm compared to the 45 × 42 mm drop. Verify contact surface and cable fit before substituting.
Cardinal Health (Kendall™) Medi-Trace™ 530 Series Foam Electrodes (adult, diaphoretic) 31013926 (series 530) Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and official catalogue: thick white foam with conductive adhesive hydrogel (solid gel), snap connection, indicated for stress, Holter and diaphoretic monitoring, in accordance with ANSI/AAMI EC 12. Drop shape of approx. 44 mm (1.75 in.): the teardrop geometry is the closest to this reference. Verify adhesive, surface and connector of the batch before substitution.
Ambu (Denmark) BlueSensor™ R (adult, foam, snap) R-00-S / R-00-S/25 Comparable by category (not interchangeable 1:1) Code confirmed in GUDID (05707480022205) and official catalogue: foam with Ag/AgCl sensor and offset snap connector, approx. 57 × 48 mm. Key difference: highly conductive wet gel versus the solid gel of this reference, and off-centre connector versus centred snap. Suitable for monitoring and stress testing; verify gel type and connector fit before replacement.

There is no manufacturer-validated equivalence table authorising 1:1 substitution between brands of monitoring electrodes: geometry, gel type, active surface and connector position affect adhesion and signal quality. Any substitution must be validated against the technical data sheet and instructions for use of the electrode and monitoring system manufacturer, checking measurements, backing, gel and connector one by one; consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

Solid gel, the choice for stable recordings: the solid gel of this reference maintains conductivity without liquid residue and is ideal for continuous monitoring, resting ECG and Holter recordings. Its 45 × 42 mm drop shape offers a good contact surface with a comfortable profile for the patient.

Variants of the same family at Cahnos: if you prefer a similar oval format, you have the NM 3642 OFI of 42.5 × 36.5 mm (ref. 0590027); for circular format with solid gel of Ø 50 mm for Holter and stress, the ST 50 RFI (ref. 0590028); for fast-acquisition liquid gel, the ST 50 RLI (ref. 0590024) or the NM 55 RLI of Ø 55 mm (ref. 14709); for rectangular format of 28 × 44 mm, the NM 2844 RFS (ref. 16115) or the NM 2844 FBI with banana connector (ref. 0590025); and if imaging tests are planned, the radiotransparent versions RT 50 RFI (ref. 0590022) and F 50 S BLUE (ref. 15843). For paediatric patients, the NM 30 RFI of Ø 30 mm (ref. 0590016). All share foam and gel technology, but differ in size, geometry and connection type.

Check the connection: confirm that the patient cable of your monitor fleet is compatible with the snap-type press stud before placing the order; if your fleet uses crocodile clips or banana connectors, consult the range of electrodes with tab and the connection adapters from Cahnos.

Preparation and storage: clean and dry the skin before application and avoid creams or oily residues to optimise contact impedance. Keep the bags sealed in a cool, dry place, rotate stock on a FIFO basis and respect the 36-month expiry date: the solid gel may lose conductivity if the packaging is opened or deteriorates. For volume orders, complete supplies or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the connection type.

Additional information

Model

NM 42 DFI

Family

Top Trace Monitoring

Product type

Conventional disposable electrode for monitoring and ECG

Backing material

Foam (medical foam) with medical-grade acrylic adhesive

Shape

Water drop (teardrop)

Measurements

45 × 42 mm (commercial diameter Ø 42 mm)

Gel

Solid conductive gel (polymerised hydrogel)

Sensor material

Ag/AgCl (silver/silver chloride)

Connection

Snap connector

Composition

Non-irritant, non-sensitising, non-cytotoxic; latex-free

Application

Cardiac monitoring, resting ECG and standard recording

Use

Single-use, disposable, non-sterile

Presentation

Bag of 50 units

Minimum sales unit

Box of 1,200 units

Main packaging

14,400 units / master carton

DC offset voltage

0.12 mV (AAMI limit ≤ 100 mV)

AC impedance 10 Hz

60 Ω (AAMI limit ≤ 2000 Ω)

DC offset 5 s

6.5 mV (AAMI limit ≤ 100 mV)

Recovery slope 30 s

0.0 mV/s (AAMI limit ≤ 1 mV/s)

Shelf life

36 months in sealed packaging

Regulatory standard

ANSI/AAMI EC 12:2000/(R)2005; Directive 93/42/EEC; class I with CE marking

Reviews

There are no reviews yet.

Be the first to review “Electrode for monitoring and ECG, foam in the shape of a water drop Ø 42 mm with solid gel – Model NM 42 DFI (Ref. Cahnos 0590029) – Bag of 50 units, box of 1,200 units.”

Your email address will not be published. Required fields are marked *